Murphy Automobile Parts EGPK 95083N User Manual

EGPK-95083N  
Revised 11-01  
Section 70  
Installation Instructions for  
Off-Equipment Mounting Kit #30000213  
of Gear Oil Pressure Sender  
(00-02-0212)  
NOTE: The pressure hose must be capable of withstanding the  
high pressure surges associated with operation of the gear. Use  
of reinforced hose with crimped-on fittings is recommended.  
NOTE: The pressure hose must NOT have a droop (low spot) in  
its mounting. Water and sludge will collect in the droop and  
prevent the pressure sender from operating.  
WARNING  
BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT  
NOTE: Use of Teflon tape or non hardening thread sealant is  
recommended.  
Disconnect all electrical power to the machine.  
Make sure the machine cannot operate during installation.  
Follow all safety warnings of the machine manufacturer.  
Read and follow all installation instructions.  
CAUTION: Do not foul the pressure orifices with tape  
or sealant.  
Refer to diagram below.  
CAUTION: This sender may be damaged by high  
frequency vibration and/or high pressure spikes.  
Mounting should be off equipment and isolated  
through the shock mounts or other suitable methods.  
1. Install the two (2) shock mounts onto the panel 30050782 and  
secure with the 1/4-20 nuts provided. Mount panel off  
equipment, if possible, and in a convenient location.  
2. Install one PD2160 pressure snubber directly into the gear  
pressure port and one onto the 1/8-27 NPT female end of the  
customer supplied fitting. Fittings of various sizes are  
available from Murphy.  
Included in the 30000213 kit are the following:  
• 1 ea. 30050782 Stainless steel panel  
• 2 ea. 65000149 shock mounts  
3. Install the customer supplied pressure hose onto the 1/8-27  
NPT ends of the PD2160 pulsation snubbers.  
4. Complete wiring according to instructions provided with the  
pressure sender.  
• 2 ea. PD2160 pressure snubber  
• 1 ea. EGPK-95083N installation sheet  
NOTE: Customer supplies a suitable pressure hose assembly  
and fitting for connection into the gear pressure port. Murphy  
can supply the hose and fitting upon request. Specify thread size  
for gear pressure port and length of hose.  
Satinless Steel Panel  
30-05-0782  
Pressure  
Sender  
Gear Casing  
High Pressure Flexible Hose  
(not included with the kit)  
PD2160  
PD2160  
Gear  
Pressure  
Port  
Mounting  
Clamp  
Correct  
Incorrect  
Shock  
Mounts (2)  
CONTROL SYSTEMS & SERVICES DIVISION  
FRANK W. MURPHY, LTD.  
MACQUARRIE CORPORATION  
1620 Hume Highway  
Campbellfield, Vic 3061; Australia  
+61 3 9358 5555 fax +61 3 9358 5558  
P.O. Box 1819; Rosenberg, Texas 77471; USA  
+1 281 633 4500 fax +1 281 633 4588  
Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.  
+44 1722 410055 fax +44 1722 410088  
FW Murphy  
P.O. Box 470248  
MURPHY DE MEXICO, S.A. DE C.V.  
Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje  
San Luis Potosí, S.L.P.; México 78384  
+52 444 8206264 fax +52 444 8206336  
Villahermosa Office +52 993 3162117  
MURPHY SWITCH OF CALIFORNIA  
41343 12th Street West  
Palmdale, California 93551-1442; USA  
+1 661 272 4700 fax +1 661 947 7570  
Tulsa, Oklahoma 74147 USA  
+1 918 317 4100  
fax +1 918 317 4266  
USA–ISO 9001:2000 FM 28221  
UK–ISO 9001:2000 FM 29422  
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.  
Printed in U.S.A.  
 

Miele Convection Oven H 4894 BP2 User Manual
Miele Microwave Oven M 635 EG User Manual
Miller Electric Welder S 32S User Manual
MTD Snow Blower 769 04179 User Manual
Multiquip Drums MT 85H User Manual
NewAir Beverage Dispenser AW 280E User Manual
NordicTrack Home Gym NTW00630 User Manual
Onkyo DVD Player DV C503 User Manual
Onkyo Stereo System TX SR700 User Manual
Panasonic Air Conditioner CS PC18JKF User Manual