Installation and Assembly:
Video Wall Mount
Model: DS-VW660
Maximum Load Capacity: 200 Ib ( 90 kg)
ISSUED: 01-05-10 SHEET #: 125-9128-1 06-28-10
1 of 10
Vertical Spacing Location
If DS-VWS0## Wall Plate Spacer Kit is not available use diagram below to determine vertical spacing.
To determine lower mounting slot position of second mount, add display height to (Y1) or (Y2)
1
DISPLAY
HEIGHT
10.25
1.688
X
Y2
Y1
.938
Vertical Location
X - 10.25 + (.938 OR 1.688) = (Y1 OR Y2)
Horizontal Spacing Location
If DS-VWS0## Wall Plate Spacer Kit is not available use diagram below to determine horizontal spacing.
To determine edge of second mount, add (Z) to edge of first mount.
DISPLAY WIDTH
16.00"
20.00"
24.00"
Z
17.50"
Horizontal Location
DISPLAY WIDTH - (35) = Z (SPACING BETWEEN MOUNTS)
ISSUED: 01-05-10 SHEET #: 125-9128-1 06-28-10
3 of 10
PARTS LIST
Description
Qty.
1
1
2
1
4
4
4
2
4
4
3
1
Part #
145-1160
145-1145
145-1158
145-1154
5S1-015-C03
590-0320
590-2233
510-1126
520-1128
520-9257
520-1023
560-9646
A carriage assembly
B wall plate
C adapter bracket
D lock bracket
E #14 x 2.5 hex head wood screw
F concrete anchor
G .38 OD x .06 LG nylon shoulder washer
H M5 x 10 mm socket pin serrated washer head screw
I
M6 x 12 mm phillips screw
J M8 x 16 mm phillips screw
K M5 x 6 mm phillips screw
L 4 mm allen wrench
A
B
C
D
I
E
F
G
H
J
K
L
ISSUED: 01-05-10 SHEET #: 125-9128-1 06-28-10
4 of 10
Installation to Wall Stud
WARNING
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder
is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs.
Installers are responsible to provide hardware for other types of mounting situations.
Use a stud finder to locate the edges of the stud. Use of an edge-to-edge stud finder is highly recommended.
Based on their edges, draw a vertical line down the stud center. Place wall plate (B) on wall as a template. Level
plate, and mark the center of the four mounting holes. Make sure that the mounting holes are on the stud center
line. Drill four 5/32" (4 mm) dia. holes 2-1/2" (65 mm) deep. Make sure that the wall plate (B) is level, secure it
using four #14 x 2.5" wood screws (E) as shown below.
1
STUD
B
E
ISSUED: 01-05-10 SHEET #: 125-9128-1 06-28-10
5 of 10
Installation to Solid Concrete or Cinder Block
WARNING
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM
C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware
and components.
solid concrete
Make sure that video wall plate (B) is level, use it
1
as a template to mark four mounting holes. Drill four
F
cinder block
5/16” (8 mm) dia. holes to a minimum depth of 2.5”
(64 mm). Insert anchors (F) in holes flush with wall
as shown (right). Place video wall mount assembly
over anchors and secure with four #14 x 2.5” screws
(E). Level, then tighten all fasteners.
WARNING
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
B
E
• Never tighten in excess of 80 in. • lb (9 N.M.).
concrete
surface
• Always attach concrete expansion anchors directly
to load-bearing concrete.
1
• Never attach concrete expansion anchors to
concrete covered with plaster, drywall, or other
finishing material. If mounting to concrete surfaces
covered with a finishing surface is unavoidable,
the finishing surface must be counterbored as
shown below. Be sure concrete anchors do not
pull away from concrete when tightening screws. If
plaster/drywall is thicker than 5/8" (16 mm), custom
fasteners must be supplied by installer
F
Drill holes and insert anchors (F).
B
2
E
F
Place wall plate (B) over anchors (F) and secure with screws (E).
INCORRECT
CORRECT
3
concrete
concrete
wall
plate
wall
plate
plaster/
drywall
plaster/
drywall
Tighten all fasteners.
ISSUED: 01-05-10 SHEET #: 125-9128-1 06-28-10
6 of 10
Attaching Adapter Brackets to Display
Attach adapter brackets (C) to back of display using four M6 x 12 mm phillips screws (I) with nylon shoulder washer (G), or four
M8 x 15 mm phillips screws (J) as shown below.
NOTE: Hardware to attach dedicated plates to the mount are included with the dedicated plates.
2
DISPLAY
I or J
G
MAX VESA-600 mm
MIN VESA-200 mm
C
400 mm
300 mm
200 mm
PLP
Attach adapter brackets (C) and display onto channels on carriage assembly (A) as shown in figure 3.1.
Secure adapter brackets (C) using lock bracket (D) with three M5 x 6 mm phillips screws (K) as shown in figure 3.2.
3
CHANNEL
DISPLAY
A
D
C
K
A
DISPLAY
BACK VIEW
FIGURE 3.1
FIGURE 3.2
ISSUED: 01-05-10 SHEET #: 125-9128-1 06-28-10
7 of 10
Horizontal Display Position
Screen and adapter brackets can slide along rail to position
.
screen horizontally
OF
OUTSIDE EDGE
OPTIONAL GUIDE: When positioning adapter brackets (C) make sure outside
edge of adapter bracket is in notch on display carriage as shown in detail 1.
ADAPTER BRACKET
600 mm
400 mm
NOTCH
300 mm
200 mm
C
PLP
FRONT
DETAIL 1
Installing Carriage Assembly to Wall Plate
Hook Carriage Assembly (A) slot onto pins on wall plate (B). Make sure that pins fully engage slot of carriage assembly (A) as
4
shown in detail 2.
SLOT
PIN
A
B
DISPLAY
SLOT
DETAIL 2
ISSUED: 01-05-10 SHEET #: 125-9128-1 06-28-10
8 of 10
Secure Carriage Assembly (A) to wall plate (B) with two M5 x 10 mm socket pin serrated washer head screws (H) using
4 mm allen wrench (L) as shown below.
5
B
H
A
Horizontal Display Adjustment
Adapter Brackets (C) and display can be adjusted horizontally.
6
ISSUED: 01-05-10 SHEET #: 125-9128-1 06-28-10
9 of 10
Carriage Assembly Adjustment
Use legend below to determine position of display.
NOTE: Each knob can be adjusted independently for fine tuning adjustments.
7
Turn knob CLOCKWISE to tighten
Turn knob COUNTER-CLOCKWISE to loosen
UP
DOWN
ROLL RIGHT
ROLL LEFT
ISSUED: 01-05-10 SHEET #: 125-9128-1 06-28-10
10 of 10
© 2010, Peerless Industries, Inc. All rights reserved.
All other brand and product names are trademarks or
registered trademarks of their respective owners.
|