Pelco Barcode Reader ips rdpe 2 User Manual

I N S T A L L A T I O N / O P E R A T I O N  
IPS-RDPE-2  
Remote Data Port  
C2473M-D (10/06)  
 
Contents  
Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
Required Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
Mounting Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
Wall Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
Pole Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Cable/Wire Requirements and Connector Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17  
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
List of Illustrations  
1
Mounting to Different Wall Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
2
3
4
5
6
7
8
9
10  
11  
12  
13  
Mounting to Pole with PA402. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
IPS-RDPE-2 Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
Coaxitron Controller with Coax Video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Coaxitron Controller with UTP Video – Passive Receiver Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
RS-422 (D or P Protocol) Controller with Coax Video – Point-to-Point Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
RS-422 (D or P Protocol) Controller with Coax Video – Home Run Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
RS-422 (D or P Protocol) Controller with Coax Video – Daisy-Chain Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
RS-422 (D or P Protocol) Controller with UTP Video – Point-to-Point Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
RS-422 (D or P Protocol) Controller with UTP Video – Home Run Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15  
RS-422 (D or P Protocol) Controller with UTP Video – Daisy-Chain Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16  
Upload Icon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17  
IPS-RDPE-2 Dimension Drawing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
C2473M-D (10/06)  
3
 
Important Safety Instructions  
1. Read these instructions.  
2. Keep these instructions.  
3. Heed all warnings.  
4. Follow all instructions.  
5. Installation should be done only by qualified personnel and conform to all local codes.  
6. Use only installation methods and materials capable of supporting four times the maximum specified load.  
7. Use stainless steel hardware to fasten the mount to outdoor surfaces.  
8. Use only replacement parts recommended by Pelco.  
9. If the unit does not have an on/off switch, the input power circuit must have a circuit breaker.  
10. A CCC-approved power cord must be used to power this equipment when used in China.  
The product and/or manual may bear the following marks:  
This symbol indicates that dangerous voltage constituting a risk of electric shock is  
present within this unit.  
CAUTION:  
RISK OF ELECTRIC SHOCK.  
DO NOT OPEN.  
This symbol indicates that there are important operating and maintenance instructions  
in the literature accompanying this unit.  
4
C2473M-D (10/06)  
 
Description  
Pelco’s IPS-RDPE-2 data port box is an on-site service tool designed for Spectra®, Esprit®, and ExSiteSeries positioning systems. The data port  
box gives on-site access for setup and testing of the positioning system.  
The IPS-RDPE-2 can be used to locally view video and control pan/tilt/zoom functions of a Spectra, Esprit, or ExSite system. The data port box can  
also upload revised operating software and language files to a Spectra or ExSite system.  
The IPS-RDPE-2 features an RJ-45 port that provides a communication interface between Pelcos positioning systems and a Windows®-based PC,  
PalmOS-compatible handheld, or iPAQpocket PC. Pelco’s serial interface cable (IPS-CABLE) is required for data transmission.  
NOTE: The IPS-RDPE-2 is compatible with Spectra IIISeries and newer model dome systems. Spectra IIand previous dome systems do not  
support this product.  
REQUIRED ACCESSORIES  
One of the following accessory options (not supplied) is required to view video, control pan/tilt/zoom, or upload revised operating software and  
language files using an IPS-RDPE-2:  
OPTION 1  
Operating software  
IPS-RMK remote monitor kit. Kit includes a 5.9-inch TFT-LCD monitor, Palm OS-compatible handheld with serial cable, and an IPS-CABLE  
OPTION 2  
Operating software  
IPS-CABLE serial interface cable  
Windows-based PC, Palm OS-compatible handheld, or iPAQ pocket PC (not available through Pelco)  
Serial interface connectors and matching connections for the PC, Palm OS-compatible handheld, or iPAQ pocket PC (not available through  
Pelco)  
Hand-held monitor (not available through Pelco)  
NOTE: To upload software the following system software must be installed:  
Spectra III dome drive must have software version 1.2 or higher installed  
ExSite explosionproof system must have software version 1.13 or higher installed  
Software cannot be uploaded to an Esprit system  
C2473M-D (10/06)  
5
 
Mounting Instructions  
WALL MOUNTING  
1. Open the lid of the IPS-RDPE-2 box. Install two 3/4-inch (1.91 cm) conduit fittings (not supplied). Close the lid of the IPS-RDPE-2 box.  
2. Determine the mounting location for the IPS-RDPE-2.  
3. Use the IPS-RDPE-2 box as a template and mark the four fastener positions on the mounting surface.  
4. Prepare the holes for installation.  
5. Attach the IPS-RDPE-2 securely with four fasteners of appropriate length. Fasteners between 1/4-inch and 5/16-inch diameter can be used  
(not supplied). Refer to Figure 1.  
MOUNTING  
HARDWARE  
(NOT SUPPLIED)  
MOUNTING HARDWARE WITH  
ANCHOR OR TOGGLE BOLT  
(NOT SUPPLIED)  
WOOD SCREW  
(NOT SUPPLIED)  
DOOR  
LATCH  
DOOR  
LATCH  
DOOR  
LATCH  
RETAINING  
SCREW  
RETAINING  
SCREW  
RETAINING  
SCREW  
CONDUIT  
FITTINGS  
CONDUIT  
FITTINGS  
CONDUIT  
FITTINGS  
WALLBOARD  
WALL  
CONCRETE WALL  
Mounting to Wallboard  
Mounting to Wall  
Mounting to Concrete  
Figure 1. Mounting to Different Wall Types  
6. Run conduit with wiring from the positioning system to the IPS-RDPE-2. To connect the wires to the IPS-RDPE-2, refer to Figure 3 or to the  
label attached to the inside lid of the data port box, and do the following:  
a. Connect the communication wires from the positioning system to the communication connector of the IPS-RDPE-2.  
NOTE: Connect all four communication wires from the Spectra dome system or ExSite system to the IPS-RDPE-2. Transmission and  
receive wires must be connected to perform software and language file uploads.  
b. Connect the power wires from the positioning system to the 24 VAC OUT positions on the power connector of the IPS-RDPE-2.  
NOTE: If preferred, separate power supplies can be used for the IPS-RDPE-2 and the positioning system.  
c. Connect the video wires/cable from the positioning system to either the BNC VIDEO IN connector (if using coaxial) or UTP VIDEO IN  
connector (if using UTP) of the IPS-RDPE-2.  
7. Run conduit with wiring from the power supply and wiring from the controller at the head-end to the IPS-RDPE-2. To connect the wires to  
the IPS-RDPE-2, refer to Figure 3 or to the label attached to the inside lid of the data port box, and do the following:  
WARNING: Turn off power to the power supply before wiring the power to the IPS-RDPE-2.  
a. Connect the power wires from the power supply to the 24 VAC IN positions on the power connector of the IPS-RDPE-2.  
b. Connect the wires/cable from the controller at the head-end to either the FROM CONTROLLER connector (D or P control), BNC VIDEO  
OUT connector (Coaxitron control), or UTP VIDEO OUT connector (UTP control) of the IPS-RDPE-2.  
6
C2473M-D (10/06)  
 
 
POLE MOUNTING  
1. Install the PA402 mount adapter. Refer to the instructions supplied with the adapter.  
2. Open the lid of the IPS-RDPE-2 box. Install two 3/4-inch (1.91 cm) conduit fittings (not supplied). Close the lid of the IPS-RDPE-2 box.  
3. Attach the IPS-RDPE-2 to the PA402 and secure with the hardware supplied with the mount adapter. Refer to Figure 2.  
IPS-RDPE-2  
CONDUIT  
PA402  
FITTINGS  
Figure 2. Mounting to Pole with PA402  
4. Run conduit with wiring from the positioning system to the IPS-RDPE-2. To connect the wires to the IPS-RDPE-2, refer to Figure 3 or to the  
label attached to the inside lid of the data port box, and do the following:  
a. Connect the communication wires from the positioning system to the communication connector of the IPS-RDPE-2.  
NOTE: Connect all four communication wires from the Spectra dome system or ExSite system to the IPS-RDPE-2.  
Transmission and receive wires must be connected to perform software and language file uploads.  
b. Connect the power wires from the positioning system to the 24 VAC OUT positions on the power connector of the IPS-RDPE-2.  
c. Connect the video wires/cable from the positioning system to either the BNC VIDEO IN connector (if using coaxial) or UTP VIDEO IN  
connector (if using UTP) of the IPS-RDPE-2.  
5. Run conduit with wiring from the power supply and wiring from the controller at the head-end to the IPS-RDPE-2. To connect the wires to  
the IPS-RDPE-2, refer to Figure 3 or to the label attached to the inside lid of the data port box, and do the following:  
WARNING: Turn off power to the power supply before wiring the power to the IPS-RDPE-2  
a. Connect the power wires from the power supply to the 24 VAC IN positions on the power connector of the IPS-RDPE-2.  
b. Connect the wires/cable from the controller at the head-end to either the FROM CONTROLLER connector (D or P control), BNC VIDEO  
OUT connector (Coaxitron control), or UTP VIDEO OUT connector (UTP control) of the IPS-RDPE-2.  
C2473M-D (10/06)  
7
 
 
Cable/Wire Requirements and Connector Locations  
Refer to Figure 3 for a layout of the data port box connectors.  
It is important to connect all four communication wires from the IPS-RDPE-2 to the Spectra dome system or ExSite system. It will not be possible  
to perform software and language file uploads if the transmit and receive wires are not connected.  
OPTIONAL  
=POSITIONING  
SYSTEM  
CONNECTIONS  
Figure 3. IPS-RDPE-2 Connections  
NOTES:  
Input power for the IPS-RDPE-2 is 24 VAC only.  
The maximum wire gauge allowed for power input and output is 12 AWG.  
The maximum wire gauge allowed for two-wire communication and unshielded twisted pair (UTP) is 16 AWG.  
8
C2473M-D (10/06)  
 
 
Wiring Diagrams  
The IPS-RDPE-2 is designed to work in both coaxial cable and UTP video transmission systems. Installation configurations include the following:  
Coaxitron Controller with Coax Video  
Coaxitron Controller with UTP Video (Passive Receiver Only)  
RS-422 (D or P) Protocol Controller with Coax Video  
Point-to-Point Configuration  
Home Run Configuration  
Daisy-Chain Configuration  
RS-422 (D or P) Protocol Controller with UTP Video  
Point-to-Point Configuration  
Home Run Configuration  
Daisy-Chain Configuration  
Refer to Figures 4 through 11 and select the desired configuration for your installation. Make all equipment connections as illustrated in the  
drawings.  
PTZ CONTROL AND  
SOFTWARE UPLOAD  
POSITIONING SYSTEM  
OR  
POWER  
TX+ TX- RX+ RX-  
VIDEO  
OUT  
PTZ CONTROL ONLY  
IPS-RDPE-2  
RX- RX+ TX- TX+  
UTP- UTP+  
RX- RX+ TX- TX+  
UTP- UTP+  
VIDEO  
IN  
VIDEO  
OUT  
TO  
POWER  
SUPPLY  
VIDEO  
IN  
COAXITRON  
CONTROLLER  
Figure 4. Coaxitron Controller with Coax Video  
NOTES:  
Input power for the IPS-RDPE-2 is 24 VAC only. The maximum wire gauge allowed for power input and output is 12 AWG.  
Refer to the manual supplied with the positioning system for wiring distances and coaxial cable requirements.  
C2473M-D (10/06)  
9
 
POSITIONING SYSTEM  
POWER  
VC-UTP  
UTP- UTP+  
TX+ TX- RX+ RX-  
PTZ CONTROL AND  
SOFTWARE UPLOAD  
IPS-RDPE-2  
RX- RX+ TX- TX+  
UTP- UTP+  
RX- RX+ TX- TX+  
UTP- UTP+  
UTP- UTP+  
COAXITRON  
CONTROLLER  
VIDEO  
IN  
VIDEO  
OUT  
TO  
POWER  
SUPPLY  
Figure 5. Coaxitron Controller with UTP Video – Passive Receiver Only  
NOTES:  
Input power for the IPS-RDPE-2 is 24 VAC only. The maximum wire gauge allowed for power input and output is 12 AWG.  
The maximum wire gauge allowed for UTP is 16 AWG.  
Refer to the manual supplied with the positioning system for wiring distances and coaxial cable requirements.  
10  
C2473M-D (10/06)  
 
PTZ CONTROL AND  
SOFTWARE UPLOAD  
POSITIONING SYSTEM  
TX+ TX- RX+ RX-  
OR  
POWER  
VIDEO  
OUT  
PTZ CONTROL ONLY  
IPS-RDP  
RX- RX+ TX- TX+  
UTP- UTP+  
RX- RX+ TX- TX+  
UTP- UTP+  
VIDEO  
IN  
VIDEO  
OUT  
TO  
POWER  
SUPPLY  
TX- TX+ RX- RX+  
CONTROL SYSTEM  
VIDEO  
IN  
AT CONTROL  
SYSTEM  
Figure 6. RS-422 (D or P Protocol) Controller with Coax Video – Point-to-Point Configuration  
NOTES:  
Input power for the IPS-RDPE-2 is 24 VAC only. The maximum wire gauge allowed for power input and output is 12 AWG.  
The maximum wire gauge allowed for two-wire communication is 16 AWG.  
Refer to the manual supplied with system for wiring distances and coaxial cable requirements.  
C2473M-D (10/06)  
11  
 
PTZ CONTROL AND  
SOFTWARE UPLOAD  
POSITIONING SYSTEM  
TX+ TX- RX+ RX-  
OR  
POWER  
PTZ CONTROL ONLY  
VIDEO  
OUT  
IPS-RDPE-2  
RX- RX+ TX- TX+  
RX- RX+ TX- TX+  
UTP- UTP+ UTP- UTP+  
TO  
POWER  
SUPPLY  
VIDEO  
IN  
VIDEO  
OUT  
PTZ CONTROL AND  
SOFTWARE UPLOAD  
POSITIONING SYSTEM  
POWER  
TX- TX+ RX- RX+  
VIDEO  
IN  
OR  
CONTROL SYSTEM  
AT CONTROL  
SYSTEM  
TX+ TX- RX+ RX-  
VIDEO  
OUT  
VIDEO  
IN  
PTZ CONTROL ONLY  
AT CONTROL  
SYSTEM  
IPS-RDPE-2  
RX- RX+ TX- TX+  
RX- RX+ TX- TX+  
UTP- UTP+ UTP- UTP+  
TO  
POWER  
SUPPLY  
VIDEO  
IN  
VIDEO  
OUT  
Figure 7. RS-422 (D or P Protocol) Controller with Coax Video – Home Run Configuration  
NOTES:  
Input power for the IPS-RDPE-2 is 24 VAC only. The maximum wire gauge allowed for power input and output is 12 AWG.  
The maximum wire gauge allowed for two-wire communication is 16 AWG.  
Refer to the manual supplied with the positioning system for wiring distances and coaxial cable requirements.  
12  
C2473M-D (10/06)  
 
PTZ CONTROL AND  
SOFTWARE UPLOAD  
POSITIONING SYSTEM  
TX+ TX- RX+ RX-  
OR  
POWER  
PTZ CONTROL ONLY  
VIDEO  
OUT  
IPS-RDPE-2  
RX- RX+ TX- TX+  
RX- RX+ TX- TX+  
UTP- UTP+ UTP- UTP+  
TO  
POWER  
SUPPLY  
VIDEO  
IN  
VIDEO  
OUT  
PTZ CONTROL AND  
SOFTWARE UPLOAD  
POSITIONING SYSTEM  
POWER  
TX- TX+ RX- RX+  
VIDEO  
IN  
OR  
CONTROL SYSTEM  
AT CONTROL  
SYSTEM  
TX+ TX- RX+ RX-  
VIDEO  
OUT  
PTZ CONTROL ONLY  
VIDEO  
IN  
AT CONTROL  
SYSTEM  
IPS-RDPE-2  
RX- RX+ TX- TX+  
RX- RX+ TX- TX+  
UTP- UTP+ UTP- UTP+  
TO  
POWER  
SUPPLY  
VIDEO  
IN  
VIDEO  
OUT  
Figure 8. RS-422 (D or P Protocol) Controller with Coax Video – Daisy-Chain Configuration  
NOTES:  
Input power for the IPS-RDPE-2 is 24 VAC only. The maximum wire gauge allowed for power input and output is 12 AWG.  
The maximum wire gauge allowed for two-wire communication is 16 AWG.  
Refer to the manual supplied with the positioning system for wiring distances and coaxial cable requirements.  
C2473M-D (10/06)  
13  
 
POSITIONING SYSTEM  
POWER  
VC-UTP  
UTP- UTP+  
TX+ TX- RX+ RX-  
PTZ CONTROL AND  
SOFTWARE UPLOAD  
IPS-RDPE-2  
RX- RX+ TX- TX+  
UTP- UTP+  
RX- RX+ TX- TX+  
UTP- UTP+  
TO  
POWER  
SUPPLY  
TX- TX+ RX- RX+  
CONTROL SYSTEM  
UTP- UTP+  
UTP RECEIVER  
AT CONTROL SYSTEM  
Figure 9. RS-422 (D or P Protocol) Controller with UTP Video – Point-to-Point Configuration  
NOTES:  
Input power for the IPS-RDPE-2 is 24 VAC only. The maximum wire gauge allowed for power input and output is 12 AWG.  
The maximum wire gauge allowed for UTP is 16 AWG.  
Refer to the manual supplied with the back box for wiring distances and coaxial cable requirements.  
14  
C2473M-D (10/06)  
 
POSITIONING SYSTEM  
POWER  
VC-UTP  
UTP- UTP+  
TX+ TX- RX+ RX-  
PTZ CONTROL AND  
SOFTWARE UPLOAD  
IPS-RDPE-2  
RX- RX+ TX- TX+  
UTP- UTP+  
RX- RX+ TX- TX+  
UTP- UTP+  
TO  
POWER  
SUPPLY  
POSITIONING SYSTEM  
POWER  
VC-UTP  
UTP- UTP+  
TX- TX+ RX- RX+  
TX+ TX- RX+ RX-  
UTP- UTP+  
CONTROL SYSTEM  
UTP RECEIVER  
PTZ CONTROL AND  
SOFTWARE UPLOAD  
AT CONTROL SYSTEM  
IPS-RDPE-2  
UTP- UTP+  
UTP RECEIVER  
AT CONTROL SYSTEM  
RX- RX+ TX- TX+  
RX- RX+ TX- TX+  
UTP- UTP+ UTP- UTP+  
TO  
POWER  
SUPPLY  
Figure 10. RS-422 (D or P Protocol) Controller with UTP Video – Home Run Configuration  
NOTES:  
Input power for the IPS-RDPE-2 is 24 VAC only. The maximum wire gauge allowed for power input and output is 12 AWG.  
The maximum wire gauge allowed for UTP is 16 AWG.  
Refer to the manual supplied with the positioning system for wiring distances and coaxial cable requirements.  
C2473M-D (10/06)  
15  
 
POSITIONING SYSTEM  
POWER  
VC-UTP  
UTP- UTP+  
TX+ TX- RX+ RX-  
PTZ CONTROL AND  
SOFTWARE UPLOAD  
IPS-RDPE-2  
RX- RX+ TX- TX+  
UTP- UTP+  
RX- RX+ TX- TX+  
UTP- UTP+  
TO  
POWER  
SUPPLY  
POSITIONING SYSTEM  
POWER  
VC-UTP  
TX- TX+ RX- RX+  
UTP- UTP+  
TX+ TX- RX+ RX-  
UTP- UTP+  
CONTROL SYSTEM  
UTP RECEIVER  
AT CONTROL SYSTEM  
PTZ CONTROL AND  
SOFTWARE UPLOAD  
UTP- UTP+  
IPS-RDPE-2  
UTP RECEIVER  
AT CONTROL SYSTEM  
RX- RX+ TX- TX+  
RX- RX+ TX- TX+  
UTP- UTP+ UTP- UTP+  
TO  
POWER  
SUPPLY  
Figure 11. RS-422 (D or P Protocol) Controller with UTP Video – Daisy-Chain Configuration  
NOTES:  
Input power for the IPS-RDPE-2 is 24 VAC only. The maximum wire gauge allowed for power input and output is 12 AWG.  
The maximum wire gauge allowed for UTP is 16 AWG.  
Refer to the manual supplied with the positioning system for wiring distances and coaxial cable requirements.  
16  
C2473M-D (10/06)  
 
Operation  
To view video, control pan/tilt/zoom, or upload revised operating software and language files to a positioning system, do the following:  
1. Open the door of the IPS-RDPE-2. Opening the door will automatically disconnect the controller at the head-end and trigger an audible alert  
at the IPS-RDPE-2 site.  
NOTE: The audible alert indicates that the data port is in service mode and also serves as a reminder to close the door after servicing the  
positioning system.  
2. Connect the RJ-45 connector of the IPS-CABLE (not supplied) to the RJ-45 port in the IPS-RDPE-2. The audible alert will stop.  
To service and/or test the positioning system, refer to the manual supplied with IPS-CABLE. The IPS-CABLE manual includes instructions for  
on-site setup, testing, and software uploads using the RJ-45 port of the IPS-RDPE-2 with a Windows-based PC, Palm OS-compatible  
handheld, or iPAQ pocket PC.  
WARNING: To prevent damage to the positioning system, never cycle power or attempt control of the system during the  
upload process. The upload process is not complete until the system reboots.  
NOTE: During software/language file upload, an icon or progress bar will appear on the monitor at the head-end to indicate data is being  
transferred to the positioning system (refer to Figure 12). The default setting for data transmission is 115.2 KB per second. Noisy and long-  
run connections will slow the transmission rate.  
3. When servicing/testing is completed, disconnect the IPS-CABLE. The audible alert is triggered. Close the door to the IPS-RDPE-2 to stop the  
audible alert and return control to the head-end.  
Figure 12. Upload Icon  
C2473M-D (10/06)  
17  
 
 
Specifications  
ELECTRICAL  
Input Voltage  
24 VAC  
Power Consumption  
1 VA  
Does not include power required for positioning system  
MECHANICAL  
Construction  
Finish  
Aluminum  
Gray polyester powder coat  
Cable Entry  
Mount Method  
Latch  
Two hole plugs will accommodate 3/4-inch (1.91 cm) conduit fittings (not supplied)  
Four 0.375-inch (0.95 cm) holes on mounting plate  
One stainless steel link-lock latch secured with screw; latch can also be secured with padlock  
(not supplied)  
GENERAL  
Environment  
Operating Range  
Weight  
Indoor/outdoor  
-50° to 122°F (-45° to 50°C)  
2.41 lb (1.09 kg)  
Rating  
Meets NEMA Type 4X standards  
(Design and product specifications subject to change without notice.)  
7.32  
(18.8)  
7.65  
(19.4)  
6.63  
(16.8)  
4.50  
(11.4)  
6.71  
(17.0)  
4.01  
(10.3)  
6.50  
(16.5)  
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS;  
ALL OTHERS ARE INCHES.  
18  
C2473M-D (10/06)  
 
PRODUCT WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in material or  
workmanship for a period of one year after the date of shipment.  
If a warranty repair is required, the Dealer must contact Pelco at (800)þ289-9100 or  
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following  
information:  
Exceptions to this warranty are as noted below:  
1. Model and serial number  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
Five years on FR/FT/FS Series fiber optic products and TW3000 Series unshielded twisted  
pair transmission products.  
Three years on Genex® Series products (multiplexers, server, and keyboard).  
If there is a dispute regarding the warranty of a product which does not fall under the  
warranty conditions stated above, please include a written explanation with the product when  
returned.  
Three years on Camclosure® and fixed camera models, except the CC3701H-2,  
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,  
which have a five-year warranty.  
Method of return shipment shall be the same or equal to the method by which the item was  
received by Pelco.  
Three years on PMCL200/300/400 Series LCD monitors.  
Two years on standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed  
dome products.  
Two years on Spectra®, Esprit®, ExSite, and PS20 scanners, including when used in  
continuous motion applications.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call the factory at  
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for  
credit, and RA number if returned for repair).  
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).  
Two years (except lamp and color wheel) on Digital Light Processing (DLP®) displays.  
The lamp and color wheel will be covered for a period of 90 days. The air filter is not  
covered under warranty.  
All merchandise returned for credit may be subject to a 20% restocking and refurbishing  
charge.  
Goods returned for repair or credit should be clearly identified with the assigned CA or RA  
number and freight should be prepaid. Ship to the appropriate address below.  
Eighteen months on DX Series digital video recorders, NVR300 Series network video  
recorders, and EnduraSeries distributed network-based video products.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:  
One year (except video heads) on video cassette recorders (VCRs). Video heads will be  
covered for a period of six months.  
Service Department  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699  
Six months on all pan and tilts, scanners or preset lenses used in continuous motion  
applications (that is, preset scan, tour and auto scan modes).  
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco  
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,  
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident  
are not covered under this warranty.  
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are  
instructed to return goods to the USA, you may do one of the following:  
If the goods are to be sent by a COURIER SERVICE, send the goods to:  
Pelco  
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from  
the specific use or application made of the Products. Pelcos liability for any claim, whether  
based on breach of contract, negligence, infringement of any rights of any party or product lia-  
bility, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such  
Products. In no event will Pelco be liable for any special, incidental or consequential damages  
(including loss of use, loss of profit and claims of third parties) however caused, whether by  
the negligence of Pelco or otherwise.  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:  
Pelco c/o Expeditors  
473 Eccles Avenue  
South San Francisco, CA 94080 USA  
Phone: 650-737-1700  
Fax: 650-737-0933  
The above warranty provides the Dealer with specific legal rights. The Dealer may also have  
additional rights, which are subject to variation from state to state.  
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.  
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union  
regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.  
REVISION HISTORY  
Manual #  
C2473M  
C2473M-A  
C2473M-B  
C2473M-C  
C2473M-D  
Date  
2/03  
1/03  
8/05  
8/06  
10/06  
Comments  
Original version.  
Revised per ECO 03-9497 for software revision.  
Added ExSite system information.  
Revised figures 1, 2, and 13 for new design, and unit weight per ECO 05-12718.  
Made references to Spectra more generic by removing series numbers. Corrected operating temperature range.  
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, ExSite, and Spectra are registered trademarks of Pelco.  
Spectra II, Spectra III, Endura, and ExSite are trademarks of Pelco.  
Palm is a trademark of Palm, Inc.  
Windows is a registered trademark of Microsoft Corporation.  
DLP is a registered trademark of Texas Instruments, Inc.  
iPAQ Pocket PC is a trademark of the Hewlett-Packard Company.  
Copyright 2006, Pelco. All rights reserved.  
 
Worldwide Headquarters  
3500 Pelco Way  
Clovis, California 93612 USA  
USA & Canada  
Tel: 800/289-9100  
Fax: 800/289-9150  
International  
Tel: 1-559/292-1981  
Fax: 1-559/348-1120  
ISO9001  
Australia Canada Finland France Italy Russia Singapore Spain Sweden The Netherlands United Arab Emirates United Kingdom United States  
|
|
|
|
|
|
|
|
|
|
|
|
 

Philips Clock Radio XP AJ 3430 User Manual
Philips Home Security System M100 User Manual
Philips MP3 Player Accessories SJM2106 User Manual
Philips Universal Remote RC136 17 User Manual
Pioneer Musical Table DJM 250 K User Manual
Pioneer Stereo Receiver VSX 415 S K User Manual
Pioneer Stereo Receiver VSX 919AH K User Manual
Polycom Conference Phone Conference Phone User Manual
Poulan Snow Blower 428510 User Manual
Poulan Trimmer 530164104 User Manual