KBD4002
MADE IN USA.
KBD4002
Genex® Multiplexer
Keyboard
Installation/
Operation Manual
C581M-B (1/04)
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120
CONTENTS
Section
Page
IMPORTANT SAFEGUARDS AND WARNINGS................................................................4
REGULATORY NOTICES ..................................................................................................4
DESCRIPTION ...................................................................................................................5
INSTALLATION ..................................................................................................................6
MULTIPLEXER MODE INSTALLATION.....................................................................6
MULTIPLEXER SERVER MODE INSTALLATION .....................................................7
OPERATION ......................................................................................................................8
PROGRAMMING ..............................................................................................................19
PASSWORD .............................................................................................................20
MENUS .....................................................................................................................20
SYSTEM SETUP (VIEW KEY)..........................................................................20
ADVANCED SYSTEM SETUP (VIEW KEY) .....................................................22
RECORD SETUP (LIVE/VCR KEY)..................................................................24
CUSTOM VCR SETUP (LIVE/VCR KEY) .........................................................26
CAMERA SETUP (NUMBER AND CAM KEYS) ...............................................27
ACTIVITY DETECTION MASK SETUP ............................................................29
SEQUENCE SETUP (SEQ KEY) ......................................................................30
HELP MENU .....................................................................................................31
MULTIPLE CAMERA DISPLAY SETUP ....................................................................32
PROGRAMMING THE PICTURE-IN-PICTURE DISPLAY (
KEY) ............32
PROGRAMMING THE 4-CAMERA DISPLAY (
PROGRAMMING THE 9-CAMERA DISPLAY (
PROGRAMMING THE 16-CAMERA DISPLAY (
KEY) ................................32
KEY) ................................33
KEY) ..............................33
PROGRAMMING MENU DEFAULTS .......................................................................34
PROGRAMMING A PRESET ....................................................................................35
PROGRAMMING A PATTERN ..................................................................................35
TROUBLESHOOTING ......................................................................................................36
SPECIFICATIONS.............................................................................................................37
WARRANTY AND RETURN INFORMATION....................................................................39
LIST OF ILLUSTRATIONS
Figure
Page
1
2
3
4
5
6
7
8
9
Switch Locations and RJ-45 Jack Pinouts .........................................................7
KBD4002 Keyboard Definitions .........................................................................9
Basic System Setup Menu ................................................................................20
Advanced System Setup Menu.........................................................................22
Basic VCR Setting Menu ..................................................................................25
Custom VCR Setup Menu .................................................................................26
Basic Camera Menu .........................................................................................27
Activity Detection Mask .....................................................................................29
Camera Sequence Menu ..................................................................................30
Help Menu .........................................................................................................30
10
LIST OF TABLES
Table
Page
A
B
C
D
E
Keyboard Addresses ..........................................................................................7
Operation Guide ................................................................................................ 11
Camera Numbers with Switch 7 ON .................................................................19
VCR Types ........................................................................................................25
Programming Menu Defaults ............................................................................34
Pelco Manual C581M-B (1/04)
3
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and
conform to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P
enclosure, it is designed for indoor use only and it must not be installed where
exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resistance
measurement between line and exposed parts to verify the exposed parts have not
been connected to line circuitry.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.
C A U T I O N :
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
This symbol indicates that there are
important operating and maintenance
instructions in the literature
accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation
and operation.
REGULATORY NOTICES
This equipment has been tested and found to comply with the limits of a Class B digital
device, pursuant to part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However there is no guarantee that the interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
=television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try and correct the interference by one or more of the following
measures:
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the re-
ceiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
4
Pelco Manual C581M-B (1/04)
DESCRIPTION
The KBD4002 Genex® Multiplexer Keyboard is a full-function keyboard controller for the
Genex MX4000 Multiplexer and the Genex MX4000SVR Multiplexer Server.
This manual covers the KBD4002 keyboard’s operation with the duplex and simplex models
of the multiplexer. The differences, as they pertain to the keyboard, will be indicated in the
text and art wherever necessary.
There are two modes of operation - multiplexer mode and multiplexer server
mode–depending on whether the keyboard is connected to a multiplexer or to a server.
In the multiplexer mode, a single keyboard interfaces up to 16 multiplexers that are
daisy-chained together. With 9-channel multiplexers, the keyboard can control up to 144
cameras; with 16-channel multiplexers, up to 256 cameras can be controlled.
In the multiplexer server mode, up to four keyboards can be connected to a server, which
interfaces up to eight multiplexers. Up to 72 cameras can be controlled with 9-channel
multiplexers or 128 cameras with 16-channel multiplexers.
In addition to performing all the control functions that can be done from the front panel of
the multiplexer, the keyboard features additional keys for full control of fixed speed and
variable speed pan, tilt, and lens functions. Variable speed control is accomplished with the
number keypad using the “select-a-speed” feature. With select-a-speed, each digit (1-9)
represents a relative pan and tilt speed. The number 1 represents the slowest speed
available while the number 9 speed equates to turbo pan (for those receivers capable of
supporting turbo pan speed). When the number 9 is entered, the tilt will operate at the
number 8 speed. Entering the number 0 sets a mid-range speed. The keyboard can also
operate presets, auxiliaries, and patterns and can be used to program the multiplexer or
server.
Pelco Manual C581M-B (1/04)
5
INSTALLATION
NOTE: The KBD4002
The following parts are supplied:
keyboard in combination with
a Genex multiplexer
provides Coaxitron® control
of pan, tilt, and lens
functions.
1
1
KBD4002 keyboard
25-foot (7.6 m) data cable
There are two modes of operation–multiplexer mode and multiplexer server mode–depending
on whether the keyboard is connected to a multiplexer or to a server.
When used with 15-bit
standard Coaxitron
In the multiplexer mode, a single keyboard is plugged into the back of a Genex MX4000
Multiplexer.
receivers, such as the
CX9000 Series, the PT7700,
and the ED25/27/28/29, the
KBD4002 in conjunction with
the multiplexer supports all
pan, tilt, and lens functions,
and AUX on/off. The
In the multiplexer server mode, up to four keyboards can be connected to the back of a
Genex MX4000SVR Multiplexer Server. A KBDKIT(-X) is required for each keyboard
connected to the remote keyboard port.
Proceed to the Multiplexer Mode Installation or Multiplexer Server Mode Installation section.
keyboard will not set or call
presets or support preset
scanning.
MULTIPLEXER MODE INSTALLATION
1. Remove the DIP switch cover plate from the rear of the keyboard (refer to Figure 1).
2. Set the switches (refer to Figure 1 for switch locations).
When used with 32-bit
extended Coaxitron
receivers, such as Esprit®,
Intercept®, Spectra®, and
LRD41C21/LRD41C22
Series, the KBD4002 in
conjunction with the
ADDRESS
Set switches 1, 2, and 3 OFF. This is address 0, which selects the multiplexer mode of
operation.
COMMUNICATION MODE
multiplexer will support all
the functions of a 15-bit
receiver, including the setting
and calling of presets and
patterns. It will not support
programming of labels for
presets or patterns. If labels
for presets or patterns are
required, they would need to
be programmed with a
different control, such as the
MPT9500.
Set switch 4 OFF to enable the polled communication mode. Use this for normal
keyboard operation.
Set switch 4 ON to put the keyboard in the non-polled communication mode. Use this
when the keyboard communicates remotely over communications media that will not
support the polled mode. This is any communications media that introduces a
significant delay in the transmission of data (for example, phone line transmission
systems). In the non-polled mode, the keyboard can be used to control multiplexer(s)
only. The non-polled mode is not supported by the multiplexer server.
UNUSED
Leave switch 5 OFF. It is not used.
TURBO MODE
Set switch 6 ON to enable the turbo pan feature. Set the switch OFF to disable the
turbo pan feature.
CAMERA ADDRESS MODE
There are two modes for addressing cameras: by addressing all the cameras
consecutively from 1-256 (refer to Table C) or by addressing the cameras in groups of
16 according to the multiplexer they are connected to. For example, multiplexer 1,
cameras 1-16; multiplexer 2, cameras 1-16, etc.
Set switch 7 ON if you want to address all cameras consecutively.
Set switch 7 OFF if you want to address cameras according to the multiplexer they are
connected to.
PROGRAMMING MODE
Set switch 8 ON to program the multiplexer and camera presets and patterns from the
keyboard. Set the switch OFF to disable programming.
6
Pelco Manual C581M-B (1/04)
3. Replace the cover on the back of the keyboard.
NOTE: For distances over
25 feet (7.6 m), you must
order the KBDKIT(-X)
Remote Keyboard Wiring
Kit. Refer to the KBDKIT(-X)
manual for installation
procedures.
4. A 25-foot (7.6 m) data cable with RJ-45 connectors is supplied with the keyboard. Plug
one end of the cable into the back of the keyboard and plug the other end into the
COM IN connector on the back of the multiplexer.
The keyboard receives power from the multiplexer. The LED display will light
momentarily when the keyboard receives power. The LED will stay on when you enter
a multiplexer address.
5. Peel off the protective covering over the LED display in the upper left corner of the
keyboard.
MULTIPLEXER SERVER MODE INSTALLATION
1. Remove the DIP switch cover plate from the rear of the keyboard (refer to Figure 1).
2. Set the switches (refer to Figure 1 for switch locations).
NOTE: If the keyboard will
be connected to a server
that will operate in the
paired mode configuration,
only addresses 1 and 3 can
be used. Refer to the server
manual for information about
the paired mode
ADDRESS
Refer to Table A to set the address of the keyboard.
Table A. Keyboard Addresses
configuration.
Keyboard
Address
Switch Settings
2
1
3
1
2
3
4
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
UNUSED
Switches 4 and 5 are not used in the multiplexer server mode. They must be placed in
the OFF position.
TURBO MODE
Set switch 6 ON to enable the turbo pan feature. Set the switch OFF to disable the
turbo pan feature.
CAMERA ADDRESS MODE
There are two modes for addressing cameras: by addressing all the cameras
consecutively from 1-256 (refer to Table C) or by addressing the cameras in groups of
16 according to the multiplexer they are connected to; for example, multiplexer 1,
cameras 1-16; multiplexer 2, cameras 1-16, etc.
PIN 1
1
2
3
4
5
6
7
8
RJ-45
JACK PINOUTS
1
2
3
4
TX+
TX–
12 VAC/DC
NONPOLAR
5 GND
6
7
RX–
RX+
}
8
Figure 1. Switch Locations and RJ-45 Jack Pinouts
Pelco Manual C581M-B (1/04)
7
Set switch 7 ON if you want to address all cameras consecutively.
Set switch 7 OFF if you want to address cameras according to the multiplexer they are
connected to.
PROGRAMMING MODE
Set switch 8 ON to program the server and the multiplexer. Set the switch OFF to
disable programming.
3. Replace the cover on the back of the keyboard.
4. Connect the keyboard to the MX4000SVR Multiplexer Server. A maximum of four
keyboards can be connected to the server. One keyboard can be connected to the
LOCAL KEYBOARD port on the server, and up to three keyboards can be connected
to the REMOTE KEYBOARD(S) port on the server. Or four keyboards can be
connected to the remote.
LOCAL KEYBOARD PORT
To connect the keyboard to the LOCAL KEYBOARD port, a 25-foot (7.6 m) data cable
with RJ-45 connectors is supplied with the keyboard. Plug one end of the cable into
the back of the keyboard and plug the other end into the LOCAL KEYBOARD port on
the server. Refer to the multiplexer server manual for instructions.
The keyboard receives power from the multiplexer. The LED display will light when the
keyboard receives power. The display will show the address of the multiplexer with
which the keyboard is communicating.
REMOTE KEYBOARD(S) PORT
To connect a keyboard(s) to the REMOTE KEYBOARD(S) port on the server you must
order a KBDKIT(-X) for each keyboard. Follow the instructions that are supplied with
the kit. Refer to Figure 1 for the keyboard RJ-45 pin-outs.
The keyboard receives power from the transformer. The LED display will light when the
keyboard receives power. The display will show the address of the multiplexer with
which the keyboard is communicating.
5. Peel off the protective covering over the LED display in the upper left corner of the
keyboard.
OPERATION
IMPORTANT NOTE ABOUT PROGRAMMING
When the keyboard is plugged into a multiplexer or multiplexer server, the keyboard is
ready to operate. However, some minimal programming may be required to
make your system work.
MULTIPLEXER
The default settings for the duplex and simplex multiplexers are not the same, and it should
not be assumed that there is nothing more to do after connecting the keyboard to the system.
Below are the minimum things to check.
1. To allow the keyboard to communicate with multiplexers in the polled mode (switch
4 OFF), you must designate one multiplexer (any one) as the master and all the others
as slaves. If you have just one multiplexer, it must be the master. In the non-polled
communication mode (switch 4 ON), all multiplexers must be slaves (the keyboard is
the master).
Set the master/slave designation from the front panel of the
multiplexer, not from the keyboard. Go to the Advanced System Setup menu
(refer to multiplexer manual) and select master or slave in the COMM. TYPE menu item.
The default is SLAVE for duplex multiplexers and MASTER (KBD T/D) for simplex
multiplexers.
8
Pelco Manual C581M-B (1/04)
2. If you have more than one multiplexer, each one must have its own address (Unit ID in
the Advanced System Setup menu). If you have a server, the multiplexer address
must match the input on the server to which it is connected; for example, if the multi-
plexer is connected to input 3 on the server, set the multiplexer address to 3. Set the
address from the front panel of the multiplexer, not from the key-
board.
3. If you have moveable cameras (they must be Coaxitron compatible), you must pro-
gram the Coaxitron format for each camera (Camera menu). The duplex multiplexer
COAXITRON FORMAT default setting is OFF, while the simplex default setting is
EXTENDED. Programming can be done from the front panel of the multiplexer or from
the keyboard (refer to the Programming section for keyboard instructions).
MULTIPLEXER SERVER
Below is the minimum you should check.
If you intend to control two monitors from one keyboard (paired mode), you must change
the settings for the monitors (Monitor menu). Programming the server can only be done
from the keyboard. Refer to the server manual for instructions.
IMPORTANT NOTE ABOUT COAXITRONCONTROL OF CAMERAS
The KBD4002 keyboard provides Coaxitroncontrol of pan, tilt, and lens functions.
The duplex multiplexer COAXITRON FORMAT (refer to the Camera Setup section)
default setting is OFF and must be changed in order to use Coaxitron control. The
simplex multiplexer default setting is EXTENDED and 32-bit Coaxitron control can be
used without changing the setting.
When used with 15-bit standard Coaxitronreceivers, such as the CX9000 Series, the
PT7700, and the ED25/27/28/29, the KBD4002 supports all pan, tilt, and lens functions,
and AUX on/off. The keyboard will not set or call presets or support preset scanning.
When used with 32-bit extended Coaxitron receivers, such as Esprit, Intercept ,
Spectra, and LRD41C21/LRD41C22 Series, the KBD4002 will support all the functions
above, including the setting and calling of presets and patterns. It will not support
programming of preset or pattern labels. If labels for presets or patterns are required, they
would need to be programmed with a different control, such as the MPT9500.
IMPORTANT NOTE ABOUT DIFFERENCES IN SIMPLEX AND
DUPLEX MULTIPLEXER MODES OF OPERATION
The simplex multiplexer has three modes of operation: live, VCR, and record.
•
•
•
In the live mode, the main monitor can show live video both in full-screen or
multiple-screen views. You cannot record in the live mode. The multiplexer’s
DISPLAY/RECORD LED is OFF.
In the VCR mode, the main monitor will show full-screen or multiple-screen views of
videotape playback. You cannot record in the VCR mode. The multiplexer’s DISPLAY/
RECORD LED is OFF.
In the record mode, the main monitor will show live video of an individual camera in
full-screen view only. You can record only when in the record mode. While recording,
all cameras are being recorded simultaneously. The multiplexer’s DISPLAY/RECORD
LED is ON.
The duplex multiplexer has two modes of operation: live and VCR.
•
In the live mode, the main monitor will show live video both in full-screen or
multiple-screen views. You can record while in this mode. The multiplexer’s LIVE/VCR
LED is ON.
•
In the VCR mode, the main monitor will show full-screen or multiple-screen views of
videotape playback. You can record in the VCR mode if you have a second VCR con-
nected to the VCR OUT jack on the multiplexer. The multiplexer’s LIVE/VCR LED is OFF.
Pelco Manual C581M-B (1/04)
9
3
2
5
7
4
6
1
8
LIVE/VCR
MONITOR
*The turbo pan feature
may be disabled. Place
switch 6 on the rear
panel DIP switch block
in the off position. See
Figure 1.
AUX
UNIT
1
MAIN
SPOT
SEQ
VIEW PATTERN PRESET
ON
IRIS
OFF
ZOOM
2
5
8
0
3
FOCUS
TELE
OPEN
NEAR
4
7
6
9
WIDE
CLOSE
R
FA
19
18
CAM
CLEAR
9
KBD4002
MADE IN USA
PAN / TILT
17
16
10
13
15
14
12
11
*
For complete instructions on how to use the keys, refer to Table B, Operation Guide.
1. LED DISPLAY Displays the address of the multiplexer
10. PATTERN KEY Press to begin a pattern. Also is used
(from 1-16) with which the keyboard is communicating.
to program a pattern.
2. LIVE/VCR KEY Selects the source of video to display
on the monitor(s). LIVE is live video from the cameras.
VCR is recorded video that is played back from a VCR.
11. PAN/TILT KEYS Provide motion control to receiver and
are used to navigate through the multiplexer programming
menus. Variable speed control is accomplished with the
number keypad using the “select-a-speed” feature. With
select-a-speed, each digit (1-9) represents a relative pan
and tilt speed. The number 1 represents the slowest speed
available while the number 9 speed equates to turbo pan*
(for those receivers capable of supporting turbo pan speed).
When the number 9 is entered, the tilt will operate at the
number 8 speed. Entering the number 0 sets a mid-range
speed.
The simplex multiplexer must be in the record mode to
record video. Check the main monitor screen to see that
it indicates REC. Press the LIVE/VCR key to change
modes.
3. ZOOM KEY Zooms in (2X or 4X) on the displayed
camera. Use the pan/tilt keys to control the zoom
location.
12. VIEW KEY Press to enter program mode for
multiplexer/multiplexer server.
4. PIP KEY Displays on the main monitor a picture-in-
picture insert on top of the full-screen display.
13. LENS CONTROL KEYS Control camera lens
functions: focus, iris and zoom.
5. FOUR-CAMERA DISPLAY KEY Press once to
display a group of four cameras on the main monitor.
Repeat pressing to display other groups.
14. SEQ KEY Starts/stops a sequence.
15. CLEAR KEY Press to clear a numeric entry.
6. NINE-CAMERA DISPLAY KEY Press once to
display a group of nine cameras on the main monitor.
Press again to display second group.
16. CAM KEY Selects a camera: Enter the camera number
and then press this key.
7. 16-CAMERA DISPLAY KEY Press once to display all
17. NUMBER PAD Enter numbers.
16 cameras on the main monitor.
18. MONITOR KEYS Select the main or spot monitor for
viewing individual cameras. A green LED above each key
indicates which monitor is selected.
8. AUXILIARY KEYS Turn receiver auxiliary functions on
and off.
9. PRESET KEY Sends a camera to a preset: Enter the
preset number and then press this key. Also is used for
programming presets.
19. UNIT KEY Selects the multiplexer with which the
keyboard communicates: Enter the address of the
multiplexer (1-16) and then press this key.
Figure 2. KBD4002 Keyboard Definitions
10
Pelco Manual C581M-B (1/04)
Table B. Operation Guide
NOTE: References to switch 7 in this table refer to the switch behind the panel on the back of the keyboard. There are two
modes for addressing cameras: by addressing all the cameras consecutively from 1-256 (switch 7 ON, refer to Table C) or by
addressing the cameras in groups of 9 or 16 according to the multiplexer they are connected to (switch 7 OFF); for example,
multiplexer 1, cameras 1-9 or 1-16; multiplexer 2, cameras 1-9 or 1-16, etc.
OPERATION
KEYBOARD COMMAND
RESULT
Use the “select-a-speed”
feature to operate pan
and tilt units with
Enter a number, 1-9, from the number keypad followed by
one of the pan/tilt keys. Each number represents a relative
pan and tilt speed with number 9 equaling turbo pan speed
(on equipped receivers) and number 1 equaling crawl
speed (the slowest speed). When the number 9 is entered,
the tilt will operate at the number 8 speed. Entering the
number 0 sets a mid-range speed.
The speed that is selected will
remain in memory until it is changed.
variable speed.
Call a camera to the
MAIN monitor.
1. Press the MAIN MONITOR key. The green LED over the
MAIN key lights.
Stops a sequence if one is in
progress. Displays the camera on
the MAIN monitor.
2. Select the camera.
Addressing by Multiplexer (Switch 7 OFF)
a. On the number pad, press the address number of the
multiplexer (1-16 if the keyboard is connected to a
multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key. The LED displays
the address.
b. On the number keypad press the number of the
camera (1-16), then press the CAM key.
Addressing Consecutively (Switch 7 ON)
On the number keypad press the number of the camera,
then press the CAM key. Refer to Table C for camera
numbers.
3. Press the LIVE/VCR key to select the mode of operation.
Displays the camera on the SPOT
monitor.
Call a camera to the
SPOT monitor.
1. Press the SPOT MONITOR key. The green LED over the
SPOT key lights.
2. Select the camera.
Addressing by Multiplexer (Switch 7 OFF)
a. On the number pad, press the address number of the
multiplexer (1-16 if the keyboard is connected to a
multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key. The LED displays
the address.
b. On the number keypad press the number of the
camera (1-16), then press the CAM key.
Addressing Consecutively (Switch 7 ON)
On the number keypad press the number of the camera,
then press the CAM key. Refer to Table C for camera
numbers.
(Continued on next page)
Pelco Manual C581M-B (1/04)
11
Table B. Operation Guide (Continued)
OPERATION
KEYBOARD COMMAND
RESULT
Set main tracking.
Spot monitor follows the camera
switching that occurs on the main
monitor in single screen mode. In
multi-screen mode, the spot
1. Go to the Advanced System Setup menu.
2. Press the pan/tilt keys so the cursor highlights SPOT
MONITOR DISPLAY items.
monitor switches to camera 1.
3. Press the OPEN key until TRACK MAIN is displayed.
4. Exit the Advanced System Setup menu.
Allows only P/T/Z control while in
main monitor mode. Press the
SPOT key to have presets and
patterns while in this mode.
1. Go to the Advanced System Setup menu.
Exits main tracking mode.
Exit main tracking.
2. Press the pan/tilt keys so the cursor highlights SPOT
MONITOR DISPLAY items.
3. Press the OPEN key until either SEQUENCE or BLANK
is displayed.
4. Exit the Advanced System Setup menu.
Call a group of cameras
to the MAIN monitor.
Displays the group of cameras on
the MAIN monitor.
1. Press the MAIN MONITOR key. The green LED over the
MAIN key lights.
2. On the number pad, press the address number of the
multiplexer (1-16 if the keyboard is connected to a
multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key. The LED displays the
address.
3. Press the key below the 4, 9, or 16 icon.
4. Repeat pressing the key until the correct group is
displayed (4 or 9 only).
5. Press the LIVE/VCR key to select the mode of
operation.
(Continued on next page)
12
Pelco Manual C581M-B (1/04)
Table B. Operation Guide (Continued)
OPERATION
KEYBOARD COMMAND
RESULT
Display a picture-in-
picture (PIP) insert on
the MAIN monitor.
1. Press the MAIN MONITOR key. The green LED over the
MAIN key lights.
The full-size view appears on the
MAIN monitor with the PIP insert.
2. Select the camera that you want to display full size.
Addressing by Multiplexer (Switch 7 OFF)
a. On the number pad, press the address number of the
multiplexer (1-16 if the keyboard is connected to a
multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key. The LED displays
the address.
b. On the number keypad press the number of the
camera (1-16), then press the CAM key.
Addressing Consecutively (Switch 7 ON)
On the number keypad press the number of the
camera, then press the CAM key. Refer to Table C for
camera numbers.
3. Make sure the main monitor displays live video. If the
video is not live, press the LIVE/VCR key.
4. Press the PIP icon key.
5. On the number keypad press the number of the camera
you want to display in the insert. Then press the CAM
key. (Note: Both cameras must be connected to the
same multiplexer.)
NOTE: In order to change the
camera shown on the full screen
view, you must exit the PIP mode.
6. To change the display in the insert, press the number of
the camera, then press the CAM key.
7. To exit, press the PIP icon key.
1. Press the MAIN MONITOR key. The green LED over
the MAIN key lights.
Stops a sequence if one is in
progress. Displays a 2X or 4X
zoom of the camera selected on
the MAIN monitor.
Zoom on a camera on
the MAIN monitor.
2. Select the camera.
Addressing by Multiplexer (Switch 7 OFF)
a. On the number pad, press the address number
of the multiplexer (1-16 if the keyboard is connected
to a multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key. The LED displays
the address.
b. On the number keypad press the number of the
camera (1-16), then press the CAM key.
Addressing Consecutively (Switch 7 ON)
On the number keypad press the number of the
camera, then press the CAM key. Refer to Table C for
camera numbers.
3. Press the LIVE/VCR key to select the mode of
operation.
4. Press the key below the ZOOM icon. The zoom
will be 2X. Press the key again for 4X zoom.
5. Use the pan/tilt keys to control the zoom location.
6. To exit, press the zoom icon key or the number of the
camera, then press the CAM key.
(Continued on next page)
Pelco Manual C581M-B (1/04)
13
Table B. Operation Guide (Continued)
OPERATION
KEYBOARD COMMAND
RESULT
1. Press the MAIN MONITOR key. The green LED over the
MAIN key lights.
Run a sequence of
cameras from one
multiplexer on the
MAIN monitor.
Starts the pre-programmed
sequence of individual cameras or
groups of cameras on the MAIN
monitor.
2. Select a camera on the multiplexer that you want to
sequence.
Addressing by Multiplexer (Switch 7 OFF)
a. On the number pad, press the address number of the
multiplexer (1-16 if the keyboard is connected to a
multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key. The LED displays
the address.
b. On the number keypad press the number of a
camera (1-16), then press the CAM key.
Addressing Consecutively (Switch 7 ON)
On the number keypad press the number of a camera,
then press the CAM key. Refer to Table C for camera
numbers.
3. Press the LIVE/VCR key to select the mode of
operation.
4. To sequence individual cameras, go to step 5. To
sequence groups of cameras, press the key below the
4- or 9-screen icon, then go to step 5.
5. Press the SEQ key.
Run a sequence of
cameras from one
multiplexer on the
1. Press the SPOT MONITOR key. The green LED over
the SPOT key lights.
Starts the sequence of individual
cameras on the SPOT monitor.
SPOT monitor. (SPOT
MONITOR DISPLAY in
the Advance System
Setup menu must be in
SEQUENCE.)
2. Select a camera on the multiplexer that you want to
sequence.
Addressing by Multiplexer (Switch 7 OFF)
a. On the number pad, press the address number of the
multiplexer (1-16 if the keyboard is connected to a
multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key. The LED displays
the address.
b. On the number keypad press the number of a
camera (1-16), then press the CAM key.
Addressing Consecutively (Switch 7 ON)
On the number keypad press the number of a camera,
then press the CAM key. Refer to Table C for camera
numbers.
3. Press the SEQ key.
Stop a sequence of
cameras on a
multiplexer.
1. Press the MAIN or SPOT MONITOR key.
Stops the sequence. The monitor
displays video from the camera on
which sequence stops.
2. On the number pad, press the address number of the
multiplexer (1-16 if the keyboard is connected to a
multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key. The LED displays the
address.
3. Press the SEQ key.
(Continued on next page)
14
Pelco Manual C581M-B (1/04)
Table B. Operation Guide (Continued)
OPERATION
KEYBOARD COMMAND
RESULT
Sequence multiple
cameras in one
location of a 4-, 9-, or
16-camera display.
The sequence will run until the
sequence key is pressed or until
another camera or multi-screen
display has been selected.
1. Select the desired multi-camera display.
2. Press and hold the multi-camera display key to enter
the multi-screen programming mode. A bar will appear
in the first camera location.
3. Use the pan/tilt keys to move the on-screen bar to the
desired camera location for sequencing, and press
sequence key to initiate the sequencing of all active
cameras.
Sequence multiplexers
connected to a server.
Starts sequencing the multiplexers
in numerical order, displaying the
main monitor first, then the spot
monitor. Monitors to be displayed
are selected in the Set Sequence
submenu of the Monitor menu of
the server. Sequencing appears on
the monitor affiliated with the
1. Hold down the SEQ key for approximately three
seconds.
keyboard; for example, if the
keyboard is set for address 1, the
sequence will appear on monitor 1.
1. Follow the steps under “Run a sequence of cameras
from one multiplexer on the MAIN monitor” or “Run a
sequence of cameras from one multiplexer on the
SPOT monitor” to start sequencing the cameras on the
main and spot monitors of individual multiplexers that
you want to sequence.
Starts sequencing the multiplexers
in numerical order, displaying the
main monitor first, then the spot
monitor. Monitors to be displayed
are selected in the Set Sequence
submenu of the Monitor menu of
the server. As each monitor is
displayed, it sequences.
Sequence multiplexers
connected to a server
and sequence cameras
on a multiplexer(s).
2. Hold down the SEQ key for approximately three
seconds to start sequencing the multiplexers.
Sequencing appears on the
monitor affiliated with the key-
board; for example, if the keyboard
is set for address 1, the sequence
will appear on monitor 1.
1. Press the
key.
Sequence the PIP
display.
Sequences all active cameras in
the PIP display.
2. Press the SEQ key.
Press a pan/tilt key or select any camera.
Sequence stops.
Stop a sequence of
multiplexers.
Program the monitor in the Advanced System Setup
menu.
Call a camera or run a
sequence of cameras
on the AUX monitor
(duplex multiplexer
only).
Monitor responds to programming
instructions.
(Continued on next page)
Pelco Manual C581M-B (1/04)
15
Table B. Operation Guide (Continued)
OPERATION
Call a preset.
KEYBOARD COMMAND
RESULT
1. Press the MAIN or SPOT MONITOR key. The green
LED over the MAIN or SPOT key lights. When using the
MAIN MONITOR, the SPOT MONITOR DISPLAY menu
item in the Advanced System Setup menu must be
set to TRACK MAIN (refer to the Advanced System
Setup section).
Moves the camera to the preset
location.
2. Select the camera.
Addressing by Multiplexer (Switch 7 OFF)
a. On the number pad, press the address number of the
multiplexer (1-16 if the keyboard is connected to a
multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key. The LED displays
the address.
b. On the number keypad press the number of the
camera (1-16), then press the CAM key.
Addressing Consecutively (Switch 7 ON)
On the number keypad press the number of the
camera, then press the CAM key. Refer to Table C for
camera numbers.
3. On the number keypad press the number of the preset,
then press the PRESET key. (Note: When calling preset
95 on Esprit™ or Spectra® systems, hold the PRESET
key until the menu appears on the screen.)
1. Press the SPOT MONITOR key. The green LED over
the SPOT key lights.
Starts auto scanning.
Start auto scan with
15-bit receiver.
2. Select the camera.
Addressing by Multiplexer (Switch 7 OFF)
a. On the number pad, press the address number of the
multiplexer (1-16 if the keyboard is connected to a
multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key. The LED displays
the address.
b. On the number keypad press the number of the
camera (1-16), then press the CAM key.
Addressing Consecutively (Switch 7 ON)
On the number keypad press the number of the
camera, then press the CAM key. Refer to Table C for
camera numbers.
3. On the number keypad press 97, then press the
PRESET key.
With system in auto scan, press 97 on the number
keypad, then press the PRESET key.
Start random scan
with 15-bit receiver.
Starts random scanning.
(Continued on next page)
16
Pelco Manual C581M-B (1/04)
Table B. Operation Guide (Continued)
OPERATION
KEYBOARD COMMAND
RESULT
1. Press the SPOT MONITOR key. The green LED over
the SPOT key lights.
Start manual scan (or
stop auto or random
scan) with 15-bit
receiver.
Stops auto or random scanning, if
operating, and activates manual
scanning.
2. Select the camera.
Addressing by Multiplexer (Switch 7 OFF)
a. On the number pad, press the address number of the
multiplexer (1-16 if the keyboard is connected to a
multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key. The LED displays
the address.
b. On the number keypad press the number of the
camera (1-16), then press the CAM key.
Addressing Consecutively (Switch 7 ON)
On the number keypad press the number of the
camera, then press the CAM key. Refer to Table C for
camera numbers.
3. On the number keypad press 96, then press the
PRESET key.
Begin a pattern.
1. Press the MAIN or SPOT MONITOR key. The green
LED over the MAIN or SPOT key lights. When using the
MAIN MONITOR, the SPOT MONITOR DISPLAY menu
item in the Advanced System Setup menu must be
set to TRACK MAIN (refer to the Advanced System
Setup section).
The pattern operates until stopped.
2. Select the camera.
Addressing by Multiplexer (Switch 7 OFF)
a. On the number pad, press the address number of the
multiplexer (1-16 if the keyboard is connected to a
multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key. The LED displays
the address.
b. On the number keypad press the number of the
camera (1-16), then press the CAM key.
Addressing Consecutively (Switch 7 ON)
On the number keypad press the number of the
camera, then press the CAM key. Refer to Table C for
camera numbers.
3. On the number keypad press 1, then press the
PATTERN key.
4. To stop the pattern, press a pan/tilt key.
(Continued on next page)
Pelco Manual C581M-B (1/04)
17
Table B. Operation Guide (Continued)
OPERATION
KEYBOARD COMMAND
RESULT
The auxiliary function operates.
Turn an auxiliary
function on or off.
1. Press the SPOT MONITOR key. The green LED over
the SPOT key lights.
2. Select the camera.
Addressing by Multiplexer (Switch 7 OFF)
a. On the number pad, press the address number of the
multiplexer (1-16 if the keyboard is connected to a
multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key. The LED displays
the address.
b. On the number keypad press the number of the
camera (1-16), then press the CAM key.
Addressing Consecutively (Switch 7 ON)
On the number keypad press the number of the
camera, then press the CAM key. Refer to Table C for
camera numbers.
3. On the number keypad press the number of the
auxiliary you want to operate, then press the AUX ON or
OFF key.
Record a tape.
For duplex multiplexer, recording is done automatically.
For simplex multiplexer, the multiplexer must be in the
record mode (DISPLAY/RECORD LED is ON).
Records all cameras connected to
the multiplexer.
For simplex multiplexer, while the
multiplexer is in the record mode
(DISPLAY/RECORD LED on ON)
you can only see a full-screen view
of one camera (or one camera at a
time if sequencing) on the main
monitor, but all active cameras are
being recorded.
Play a tape.
1. Press the MAIN MONITOR key. The green LED over the
MAIN key lights.
Displays the recorded cameras in
the selected format on the MAIN
monitor.
2. On the number pad, press the address number of the
multiplexer (1-16 if the keyboard is connected to a
multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key. The LED displays the
address.
3. Press the LIVE/VCR key to put the multiplexer in the
playback mode.
4. Select the cameras to play back from one of the
following choices:
• For an individual camera, press the number of the
camera, then press the CAM key. If switch 7 is OFF,
enter a camera number from 1-16. If switch 7 is ON,
refer to Table C for camera numbers.
• For multiple camera display, press the key below the
4, 9, or 16 icon.
• For sequencing, select an individual or multiple
camera display, then press the SEQ button.
5. Turn on the VCR and press the PLAY button.
18
Pelco Manual C581M-B (1/04)
Table C. Camera Numbers with Switch 7 ON
Multiplexer
Cameras
9-channel
16-channel
1
2
1-9
1-16
17-25
17-32
3
33-41
33-48
4
49-57
49-64
5
65-73
65-80
6
81-89
81-96
7
97-105
113-121
129-137
145-153
161-169
177-185
193-201
209-217
225-233
241-249
97-112
113-128
129-144
145-160
161-176
177-192
193-208
209-224
225-240
241-256
8
9
10
11
12
13
14
15
16
PROGRAMMING
This section applies only to programming the multiplexer. To program the
multiplexer server, refer to the server manual.
NOTE: Whenever a
multiplexer server is
installed, programming the
multiplexer must be done
at the multiplexer front
panel. In this situation, the
multiplexer cannot be
Programming allows you to configure the multiplexer from the KBD4002 for the way that
you want your system to operate. The multiplexer automatically selects the most common
operating parameters. However, some minimal programming may be required to make your
system work.
programmed from the
+keyboard. The keyboard
can only be used to
program the multiplexer
server, not the multiplexer.
Programming of system, camera, and VCR setup; camera sequencing; and alarm and ac-
tivity detection are done through on-screen menus that are displayed on the main monitor.
A password can be enabled to prevent unauthorized access to the menus.
Programming of the picture-in-picture, and 4-, 9-, and 16-camera displays can be done
directly without going through menus.
IMPORTANT NOTE
Before the keyboard can be used to control the multiplexer(s), perform the following steps at
the multiplexer(s) front panel.
1. Press the VIEW button for approximately three seconds. The basic SYSTEM Setup
menu appears.
2. The currently selected menu item blinks. Use the arrow buttons to highlight AD-
VANCED SETUP.
3. Press the +/- button. The Advanced System Setup menu appears. Skip steps 4 and 5 if
your system has only one multiplexer.
4. Use the arrow buttons to move the cursor to UNIT ID.
5. Press the +/- button to select the UNIT ID of the multiplexer.
6. Use the arrow button to move the cursor to COMM.TYPE.
7. In the polled communication mode (switch 4 OFF), one multiplexer must be the
master and all others slaves. In the non-polled mode (switch 4 ON), all multiplexers
must be slaves.
8. Use the arrow button to go to EXIT. Press the +/- button to exit the menu. The keyboard
can now be used to program the multiplexer(s).
Pelco Manual C581M-B (1/04)
19
PASSWORD
You can program the multiplexer to request a password for access to programming menus.
The password is enabled in the Advanced System Setup menu (refer to the Advanced
System Setup section).
The universal password is 3916 and cannot be changed. This password must be entered
whenever one is requested. The password is entered from the keyboard by pressing each
number followed by pressing the CAM key: 3, CAM, 9, CAM, 1, CAM, 6, CAM.
MENUS
To program from the keyboard you have to be in main monitor mode. Press the MAIN
MONITOR key.
TIP: Once you are in a
menu, you can go to another
menu by pressing the key(s)
for that menu. Press and
release the VIEW key to
switch to the system setup
menu. Enter a camera
SYSTEM SETUP (View Key)
To program the main basic system parameters:
1. Press the MAIN MONITOR key.
number and then press and
release the CAM key to
change to a camera menu.
Press and hold the SEQ and
LIVE/VCR keys to switch to
the sequence and record
menus.
2. Use the number keypad to enter the address of the multiplexer (1-16 if the keyboard is
connected to a multiplexer; 1-8 if the keyboard is connected to a server), then press
the UNIT key.
3. Press the VIEW key for approximately three seconds. Type the password, if requested.
The password must be entered by pressing each number key followed by pressing the
CAM key. The System Setup menu appears. The currently selected menu item blinks.
TIP: In any menu you can
scroll the options forward by
pressing the OPEN key or
scroll backward by pressing
the CLOSE key.
4. Use the pan/tilt keys to move between items on the screen. When the menu item you
desire is highlighted (blinking), do one of the following:
•
•
If a menu item has more than one option, press the OPEN key to cycle through
the options to select the one you want.
If a menu item has only one option, press the OPEN key to select it.
Time and Date
Set the current time and date. The time uses a 24-hour clock.
Time Display
ON - Displays the time on the main monitor.
OFF - The time is not shown on the main monitor.
2/6/8 Hr
2/6/8 Hr
*2,6,or 8 Hr 120 Hr
12 Hr
16 Hr
18 Hr
24 Hr
48 Hr
72 Hr
84 Hr
96 Hr
168 Hr
180 Hr
240 Hr
360 Hr
480 Hr
600 Hr
720 Hr
960 Hr
MAIN MONITOR VIDEO
MAIN MONITOR DISPLAY HIGH RESOLUTION
**
**
HIGH RESOLUTION
REDUCED FLICKER
RESET ACTIVITY DETECTION ALL CH TO
*
2/6/8 HR FOR NTSC/EIA MODEL MULTIPLEXERS, 3 HR FOR PAL/CCIR MODELS.
REMAINING RECORD SPEEDS DEPEND UPON VCR MODEL.
** NOT SHOWN ON DUPLEX MONOCHROME MODELS OR SIMPLEX MULTIPLEXERS
Figure 3. Basic System Setup Menu
20
Pelco Manual C581M-B (1/04)
Title Display (Duplex Multiplexer)
ON - Displays camera titles and the word LIVE or VCR on the main monitor.
OFF - Camera titles and the word LIVE or VCR are not shown on the main monitor.
NOTE: Title Display shows a
maximum of 12 characters in
all modes except 16-camera
display, in which only 9 char-
acters are shown.
Title Display (Simplex Multiplexer)
ON - Displays camera titles on the main monitor.
OFF - Camera titles are not shown on the main monitor.
Record Speeds
Sets the speed at which the VCR normally records video and the speed at which it
records when there is an alarm(s). Setting the speeds in the System Setup menu also
sets the speeds in the Record Setup and Custom VCR Setup menus.
Main Monitor Video (Duplex Multiplexer Color Models Only)
Composite is standard video on coaxial cable. SVHS is higher resolution video on a
special cable.
Main Monitor Display
The options are High Resolution or Reduced Flicker. Reduced Flicker can be selected
when there is flickering on the monitor screen, such as from a neon light. This problem
is more visible to the eye in PAL format multiplexers.
GLOBAL SETUPS
Video Terminations
These settings set the terminations for all video inputs. To set individual inputs, refer
to the Camera Setup section.
Set to 75 OHM when equipment is connected only to the video IN connectors. There
must be no equipment connected to the video OUT connectors.
Set to LOOP HI-Z when equipment is connected to the video OUT (looping) connectors.
For every channel that has equipment connected to the video IN connector, there
must be equipment connected to the video OUT connector. Do not use this global
setting if any channel has equipment connected to a video input but no equipment
connected to the video output. Equipment connected to the looping connectors must
be terminated at 75 ohms.
NO CHANGE - This is a pass-through selection in case you unintentionally hit the
OPEN key. This is not an undo key.
Alarm Inputs
Normally closed operation = current flow = alarm switch or relay closed.
Normally open operation = no current flow = alarm switch or relay open.
Dwell Rates
Sets the sequence dwell rate for all cameras. To set individual dwell rates for
cameras, refer to the Sequence Setup section.
Activity Detection
ENABLED/DISABLED - Turns activity detection on or off for all video inputs. To set
individual inputs, refer to the Camera Setup section.
NO CHANGE - This is a pass-through selection in case you unintentionally hit the
OPEN key. This is not an undo key.
5. When you have completed all the changes you want to make, go to EXIT or
ADVANCED SETUP.
6. Press the OPEN key to exit the programming mode or to go to the advanced system
setup menu.
When HELP is highlighted, you may press the OPEN key to display a help screen that will
tell you which keys to press to configure specific options.
Pelco Manual C581M-B (1/04)
21
ADVANCED SYSTEM SETUP (View Key)
To program the advanced main system parameters:
1. Press the MAIN MONITOR key.
2. Use the number keypad to enter the address of the multiplexer (1-16 if the keyboard is
connected to a multiplexer; 1-8 if the keyboard is connected to a server), then press
the UNIT key.
3. Press the VIEW key for approximately three seconds. The basic System Setup menu
appears.
4. The currently selected menu item blinks. Use the pan/tilt keys to highlight ADVANCED
SETUP.
5. Press the OPEN key. The Advanced System Setup menu appears.
6. Use the pan/tilt keys to move between items on the screen. When the menu item you
desire is highlighted (blinking), press the OPEN key to cycle through the options.
Date Format
Sets the format for displaying the date on the main monitor.
Password
Enables or disables password control to access programming menus.
Front Panel Control
Enables or disables the front panel buttons to operate the multiplexer. In either mode
you can access programming menus. Has no effect on the keyboard.
Main Monitor Display
Select ALARMS, ACTIVITY, or ALARMS/ACTIVITY if you want the main monitor to
switch to cameras that have alarms or activity detection. If you are using the main
monitor for normal video and you do not want alarms or activity detection to override
what you are observing, select NONE.
DATE FORMAT
PASSWORD
MM-DD-YY
DISABLED
FRONT PANEL CONTROL ENABLED
MAIN MONITOR DISPLAY
SEQUENCE
BLANK
TRACK MAIN
RESPONDS TO
NONE
SPOT MONITOR DISPLAY SEQUENCE
RESPONDS TO ALARMS
***
***
AUX MONITOR DISPLAY BLANK
RESPONDS TO
ACTIVITY
CAMERA TYPES
ALL COLOR
BLANK
CAM 1
UNIT ID
COMM. TYPE
001
MASTER (KBD-T/D)
CAM 16
SEQUENCE
RELAY OUTPUT
ALARM
ALL COLOR*
COLOR & B/W
RESERVED
001–240
MASTER (KBD-T/D)** (1)
SLAVE
(2)
*
ALL B/W SHOWN ON MONOCHROME MODELS.
(1) SIMPLEX DEFAULT SETTING
(2) DUPLEX DEFAULT SETTING
** MUST BE SET IN THIS MODE FROM THE FRONT PANEL OF THE
MULTIPLEXER TO PROGRAM THE MULTIPLEXER FROM THE KEYBOARD.
*** DUPLEX MULTIPLEXER ONLY; NOT ON SIMPLEX
Figure 4. Advanced System Setup Menu
22
Pelco Manual C581M-B (1/04)
Spot Monitor Display
If you want the spot monitor to switch to cameras that have alarms or activity
detection, select BLANK, SEQUENCE, or TRACK MAIN, then under RESPONDS TO
select ALARMS, ACTIVITY, or ALARMS/ACTIVITY. If you are using the spot monitor
for normal video and you do not want alarms or activity detection to override what you
are observing, select NONE.
BLANK - Allows you to view an individual camera, but you cannot run a sequence. An
alarm or activity detection will override the camera you are viewing. When the alarm or
activity detection goes away, the screen will return to the camera you were viewing.
SEQUENCE - Allows you to view an individual camera or run a sequence. An alarm or
activity detection will override what you are observing. When the alarm or activity
detection goes away, the screen will return to the camera or sequence you were
viewing.
TRACK MAIN - The spot monitor will follow the camera switching that occurs on the
main monitor. This feature is used only when a KBD4002 keyboard is connected to the
multiplexer for controlling moveable cameras. This mode provides an easy method of
simplifying P/T/Z control in single-monitor applications. The operator does not have to
switch to SPOT to gain P/T/Z control and there is no separate control of the spot
monitor when in this mode. However, to do presets and patterns, switch to SPOT.
Aux Monitor Display (Duplex Multiplexer Only)
Select ALARMS, ACTIVITY, or ALARMS OR ACTIVITY if you want the auxiliary
monitor to show cameras with alarms or activity detection. If you are using the
auxiliary monitor to sequence all cameras and you do not want alarms or activity
detection to override the sequence, select NONE.
BLANK - This means the screen will remain blank unless there is an alarm or activity
detection.
SEQUENCE - This means the monitor will sequence all cameras unless there is an
alarm or activity detection.
CAM 1 through CAM 16 - This means the monitor will display the selected camera
unless there is an alarm or activity detection.
Camera Types
The COLOR & B/W setting allows the multiplexer to adapt to the combination of both
color and monochrome video signals. The switching speed of the multiplexer is not as
fast when it has to change formats between monochrome and color cameras. For
duplex monochrome models, you will not receive color from a color camera except
on the SPOT or AUX monitor displays. For simplex monochrome models, you will
not receive color from a color camera except in RECORD mode.
CAUTION: When
programming the
MX4000
The RESERVED setting can improve performance when using cameras with
non-standard sync or poor video quality.
Multiplexer from the
Unit ID
KBD4002 Keyboard, DO
NOT ATTEMPT TO
CHANGE THE UNIT ID.
Changing the unit ID from
the keyboard will interrupt
the keyboard
communications to the
multiplexer, resulting in
erratic multiplexer operation.
Refer to the Troubleshooting
section, in this manual to
correct the situation.
This is the address of the multiplexer. If your system has more than one multiplexer,
each multiplexer must have its own address. This must be set at the multiplexer, not at
the keyboard.
Comm.Type
In the polled communication mode (switch 4 OFF), one multiplexer (any one) must
be the master. Only one multiplexer can be the master. All other multiplexers must be
slaves. The master multiplexer communicates with the slave multiplexers.
In the non-polled communication mode (switch 4 ON), all multiplexers must be
slaves.
The default is SLAVE for duplex multiplexers and MASTER (KBD T/D) for simplex
multiplexers.
Pelco Manual C581M-B (1/04)
23
Relay Output
Operates the relay on the back of the multiplexer. The relay is used to change the VCR
to its alarm recording speed. In the alarms mode, an alarm signal is produced when a
remote switch opens or closes a ground in the multiplexer; for example, if a switch is
on a door and the door is opened. In the activity mode, the multiplexer continually
monitors select camera inputs for motion. When motion is detected, the multiplexer
increases the frequency with which that camera(s) is shown and recorded. Activity
detection is most effective when only a few cameras are showing activity (refer to the
Camera Setup section).
7. When you have completed all the changes you want to make, go to EXIT or BASIC SETUP.
8. Press the OPEN key to exit the programming mode or to go to the basic system setup
menu.
When HELP is highlighted, you may press the OPEN key to display a help screen that will
tell you which keys to press to configure specific options.
RECORD SETUP (Live/VCR Key)
To program the VCR recording parameters:
1. Press the MAIN MONITOR key.
2. Use the number keypad to enter the address of the multiplexer (1-16 if the keyboard is
connected to a multiplexer; 1-8 if the keyboard is connected to a server), then press
the UNIT key.
3. Press the LIVE/VCR key for approximately three seconds. Type the password,
if requested. The Record Setup menu appears. The currently selected menu item
blinks.
4. Use the pan/tilt keys to move between items on the screen. When the menu item you
desire is highlighted (blinking), press the OPEN key to cycle through the options to
select the one you want.
Record Speeds
Sets the speed at which the VCR normally records video and the speed at which it
records when there is an alarm(s). Setting the speeds in the Record Setup menu also
sets the speeds in the System Setup and Custom VCR Setup menus.
VCR Type (See Table D)
If your VCR is not listed among the options, do either of the following:
• Select UNIVERSAL. In the recording speed menu item at the top of the screen,
select an option that your VCR will support.
• Select CUSTOM. Then go to CONFIGURE CUSTOM VCR and press the OPEN
key to go to the Custom VCR Setup menu. The switch interval can be changed only
while in this setting.
VCR Video Format
This feature is not available on monochrome multiplexers. Composite is standard
video on a coaxial cable. SVHS is higher resolution video on a special cable.
VCR Switch Pulse
ENABLED means the multiplexer waits for a head switching pulse from the VCR. If the
multiplexer does not get a pulse from the VCR (because of a broken wire or the VCR
does not give a pulse in some modes), it may appear that the multiplexer is not
working properly.
DISABLED means the VCR head switching pulse is not used.
Alarm Handling
Determines how alarms are recorded and for how long.
Configure Custom VCR
Press the OPEN key to get to the CUSTOM VCR SETUP menu.
Playback Format
Tapes made using Pelco, Robot, and DM multiplexers can be played.
24
Pelco Manual C581M-B (1/04)
*2,6,or 8 Hr 24 Hr 96 Hr 240 Hr
12 Hr
16 Hr
18 Hr
48 Hr 120 Hr 360 Hr
72 Hr 168 Hr 480 Hr
84 Hr 180 Hr 600 Hr
720 Hr
NORMAL REC. SPEED
ALARM REC. SPEED
2/6/8 Hr
2/6/8 Hr
960 Hr
SEE TABLE D
VCR SETUP
**
VCR TYPE
VCR VIDEO FORMAT
VCR SWITCH PULSE
UNIVERSAL
COMPOSITE
DISABLED
**
ENABLED
DISABLED
ALARM HANDLING
RECORD ALARMS AS A PRIORTIY
ALARM RECORD TIME
ALARM DURATION
ALARM DURATION
30 SECONDS
1 MINUTE
CONFIGURE CUSTOM VCR
PLAYBACK FORMAT
PELCO
2 MINUTES
5 MINUTES
10 MINUTES
15 MINUTES
PELCO
ROBOT
DM
* 2/6/8 HR FOR NTSC/EIA MODEL MULTIPLEXERS, 3 HOUR FOR PAL/CCIR MODELS.
REMAINING RECORD SPEEDS DEPEND UPON VCR MODEL.
** NOT SHOWN ON MONOCHROME MODELS.
Figure 5. Basic VCR Setting Menu
Table D. VCR Types
NTSC
PAL
UNIVERSAL
UNIVERSAL
GYYR TLC1800
GYYR 2100
GYYR 2100 HD MODE
JVC SR-L900U
JVC SR-L901U
ASUTA TLVCR 251
ASUTSA TLVCR 964
BURLE TC3910X
HITACHI VTL30E
HITACHI VT-L1000E
HITACHI VT-L2000E
JVC BR9060E
JVC SR-9070U
JVC BR-S925U
MITSUBISHI HS7424U
MITSUBISHI HS7496U
MITSUBISHI HS5168U
MITS. HS7168U NORM
MITS. HS7168U HD
PANASONIC AG-RT600
PANASONIC AG6124
PANASONIC AG 6730
PELCO TLR2024
JVC BR-S920/925
JVC SR-L900E
MITS. HS5300/5600
MITS. HS5424E
PANAS.AG6024/6124
PANASONIC AG6720
PANASONIC AG6730
PANASONIC AG6040
SANYO TLS900P
SANYO TLS1000
SANYO SRT-500P
SANYO TLS2000
SONY SVT100P
SONY SVT5000P
CUSTOM
PELCO TLR2096
PELCO TLR2168 NORM
PELCO TLR2168HD
SANYO SRT600
SANYO TLS924/972
SANYO TLS2500/7000
TOSHIBA KV6300
TOSHIBA KV7024A
TOSHIBA KV7168A
TOSHIBA KV7960A
TOSHIBA KV8168A
CUSTOM
Pelco Manual C581M-B (1/04)
25
5. When you have completed all the changes you want to make, go to EXIT.
6. Press the OPEN key to exit the programming mode.
When HELP is highlighted, you may press the OPEN key to display a help screen that will
tell you which keys to press to configure specific options.
CUSTOM VCR SETUP (Live/VCR Key)
NOTE: For proper record-
ing, the switching rate of the
multiplexer must match that
of the VCR. If they do not
match, the VCR may skip
frames or record duplicate
frames.
To program the advanced VCR parameters:
1. Press the MAIN MONITOR key.
2. Use the number keypad to enter the address of the multiplexer (1-16 if the keyboard is
connected to a multiplexer; 1-8 if the keyboard is connected to a server), then press
the UNIT key.
3. Press the LIVE/VCR key for approximately three seconds. The Record Setup menu
appears. The currently selected menu item blinks.
4. Make sure the VCR Type in the Record Setup menu is set to CUSTOM.
5. Use the pan/tilt keys to highlight CONFIGURE CUSTOM VCR.
6. Press the OPEN key. The Custom VCR Setup menu appears.
7. Use the pan/tilt keys to move between items on the screen. When the menu item you
desire is highlighted (blinking), press the OPEN key to cycle through the options.
Record Speeds
Sets the speed at which the VCR normally records video and the speed at which it
records when there is an alarm(s).
Setting the speeds in the Custom VCR Setup menu also sets the speeds in the System
Setup and Record Setup menus.
Interval
Interval is the number of fields recorded by the VCR before switching to the next camera.
8. When you have completed all the changes you want to make, go to EXIT or BACK.
9. Press the OPEN key to exit the programming mode or to return to the Record Setup
menu.
When HELP is highlighted, you may press the OPEN key to display a help screen that will
tell you which keys to press to configure specific options.
*2,6,or 8 Hr 120 Hr
12 Hr
16 Hr
18 Hr
24 Hr
48 Hr
72 Hr
84 Hr
96 Hr
168 Hr
180 Hr
240 Hr
360 Hr
480 Hr
600 Hr
720 Hr
960 Hr
NORMAL RECORD SETUP
RECORD SPEED 2/6/8 Hr
SWITCH INTERVAL 003
ALARM RECORD SETUP
RECORD SPEED 2/6/8 Hr
SWITCH INTERVAL 003
003 TO 509 **
BACK
EXIT
*2/6/8 HR FOR NTSC/EIA MODEL MULTIPLEXERS, 3 HR FOR PAL/CCIR MODELS.
REMAINING RECORD SPEEDS DEPEND UPON VCR MODEL.
** VCR TYPE IN RECORD SETUP MENU MUST BE SET TO CUSTOM IN ORDER TO
MAKE SELECTIONS.
Figure 6. Custom VCR Setup Menu
26
Pelco Manual C581M-B (1/04)
CAMERA SETUP (Number and CAM Keys)
To program a camera input:
1. Press the MAIN MONITOR key.
2. Select the camera.
Addressing by Multiplexer (Switch 7 OFF)
a. On the number keypad, enter the address number of the multiplexer (1-16 if the
keyboard is connected to a multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key.
b. On the number keypad, enter the number of the camera, then press and hold the
CAM key until the Camera menu appears.
Addressing Consecutively (Switch 7 ON)
On the number keypad, enter the number of the camera, then press and hold the CAM
key until the Camera menu appears. Refer to Table C for camera numbers.
3. A video insert appears that shows what the camera is viewing. This is useful to make
sure you have selected the correct camera and to see what effect there is on the video
when you select a menu option. The currently selected menu item blinks.
4. Use the pan/tilt keys to move between items on the screen. When the menu item you
desire is highlighted (blinking), press the OPEN key to cycle through the options to
select the one you want. Use the right pan key to advance to the next character
position when titling a camera.
Video Termination
Set to 75 OHM when equipment is connected only to the video IN connector.
Set to LOOP HI-Z when equipment is also connected to the video OUT (looping)
connector. Equipment connected to the looping connector must be terminated at 75
ohms.
Alarm Input
Normally closed operation = current flow = alarm switch or relay closed.
Normally open operation = no current flow = alarm switch or relay open.
ENTER UP TO 12* NUMBERS,
LETTERS OR SYMBOLS
VIDEO INPUT TERMINATION 75 OHM
ALARM INPUT NORMALLY
COAXITRON FORMAT
OPEN
EXTENDED
ACTIVITY DETECTION
SET DETECTION MASK
ENABLED
ENABLED
DISABLED
OPEN
CLOSED
DISABLED
EXTENDED (1)
OFF (2)
STANDARD
*
ONLY NINE CHARACTERS APPEAR WHEN IN THE 16-CAMERA DISPLAY.
(1) SIMPLEX DEFAULT SETTING
(2) DUPLEX DEFAULT SETTING
Figure 7. Basic Camera Menu
Pelco Manual C581M-B (1/04)
27
NOTE: The Coaxitron format
default setting is OFF for the
duplex multiplexer and EX-
TENDED for the simplex mul-
tiplexer.
Coaxitron Format
EXTENDED - Use when your system has moveable cameras controlled by 32-bit
Coaxitron receivers, such as Esprit, Intercept, Spectra, and LRD41C21/LRD41C22
Series.
OFF - Use when your system has fixed cameras only.
STANDARD - Use when your system has moveable cameras controlled by 15-bit
Coaxitron receivers, such as the CX9000 Series, the PT7700, and the ED25/27/28/29.
Activity Detection
A camera can be set to respond or not to respond to motion. If enabled select SET
DETECTION MASK to define what part of the camera’s viewing field will be monitored
for motion.
5. To program another camera, press the number key for that camera then press the
CAM key. Repeat steps 2-4.
6. When you have completed all the changes you want to make, go to EXIT.
7. Press the OPEN key to exit the programming mode.
When HELP is highlighted, you may press the OPEN key to display a help screen that will
tell you which keys to press to configure specific options.
28
Pelco Manual C581M-B (1/04)
ACTIVITY DETECTION MASK SETUP
Activity detection continually monitors selected camera inputs for motion. When motion is
detected, the multiplexer increases the frequency with which that camera(s) is shown and
recorded. Activity detection is most effective when only a few cameras are showing activity.
As the number of cameras with activity increases, the slower the frequency at which they
can be shown and recorded. If all 16 cameras show activity, there will be virtually no
increase.
The activity detection mask selects that portion or portions of the camera’s field of view that
the multiplexer will monitor for motion. The entire grid is active on default.
To program an activity detection mask for a camera:
1. Press the MAIN MONITOR key.
2. Select the camera.
Addressing by Multiplexer (Switch 7 OFF)
a. On the number keypad, enter the address number of the multiplexer (1-16 if the
keyboard is connected to a multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key.
b. On the number keypad, enter the number of the camera, then press and hold the
CAM key until the Camera menu appears.
Addressing Consecutively (Switch 7 ON)
On the number keypad, enter the number of the camera, then press and hold the CAM
key until the Camera menu appears. Refer to Table C for camera numbers.
3. The currently selected menu item blinks. Use the pan/tilt keys to highlight
SET DETECTION MASK.
4. Press the OPEN key. The Activity Detection Mask appears. The currently selected
menu item or activity box blinks.
5. Use the pan/tilt keys to move between menu items and activity boxes on the screen.
6. Highlight the sensitivity menu item. Press the OPEN key to select the sensitivity.
The higher the sensitivity is, the less the amount of motion that will be needed to
detect activity.
LOW SENSITIVITY
MED SENSITIVITY
HIGH SENSITIVITY
ACTIVITY DETECTION MED SENSITIVITY
SET ALL CLEAR ALL EXIT TEST
ACTIVITY BOX SET
ACTIVITY BOX CLEAR
Figure 8. Activity Detection Mask
Pelco Manual C581M-B (1/04)
29
7. Turn activity boxes on or off (by default, all activity boxes are on).
To turn on all activity boxes, use the pan/tilt keys to choose SET ALL. Press the OPEN
key. All boxes will contain a symbol as shown in Figure 8. The multiplexer will monitor
motion in those boxes.
To turn off all activity boxes, use the pan/tilt keys to choose CLEAR ALL. Press the
OPEN key. All boxes will be blank.
To turn on or off an individual box, use the pan/tilt keys to select the box. Press OPEN
key to toggle a box on or off.
Turn off activity boxes where you want motion ignored, such as blowing trees, high-
ways, computer monitors, fluorescent lighting, and non-problem areas. An example of
a non-problem area would be a camera focused on a bank vault entrance but ignoring
tellers working nearby.
8. To test the activity detection, highlight TEST and press the OPEN key.
Create motion in front of the camera. Small black and white dashes will flash where
motion is detected.
To exit the test mode, press the OPEN key to return to the mask.
9. If you did not like what you saw in the test mode, change the mask and test the activity
detection again.
10. When you finish defining the activity detection mask, go to EXIT. Press the OPEN or
CLOSE key to exit the programming mode.
11. If necessary, repeat steps 1-10 to program the activity detection mask for other cameras.
SEQUENCE SETUP (SEQ Key)
Sequencing can be programmed in full screen, four-camera and nine-camera displays.
The cameras will not sequence when operating the zoom function. The LED(s) above the
camera button(s) on the multiplexer will illuminate to indicate which camera(s) is being
displayed.
To program camera sequencing:
1. Press the MAIN MONITOR key.
2. Use the number keypad to enter the address of the multiplexer (1-16 if the keyboard is
connected to a multiplexer; 1-8 if the keyboard is connected to a server), then press
the UNIT key.
3. Press the SEQ key for approximately three seconds. Type the password, if requested.
The Sequence menu appears. The currently selected menu item blinks.
4. Use the pan/tilt keys to move between items on the screen. When the menu item you
desire is highlighted (blinking), press the OPEN key to cycle through the options to
select the one you want.
5. When you have completed all the changes you want to make, go to EXIT.
6. Press the OPEN key to exit the programming mode.
When HELP is highlighted, you may press the OPEN key to display a help screen that will
tell you which keys to press to configure specific options.
30
Pelco Manual C581M-B (1/04)
GROUP
QUAD (2x2)
NINE (3x3)
04
04
1
2
3
4
04
04
04
04
Figure 9. Camera Sequence Menu
HELP MENU
The Help menu is accessed from any other menu.
1. Use the pan/tilt keys in any menu to highlight HELP.
2. Press the OPEN key. The Help menu appears.
HELP
BUTTON
VCR/LIVE
SETTING
VCR SPEED & ALARM
*
QUICK SETUP
MONITOR SETUP
+/–
- SINGLE PRESS MODIFY
DOUBLE PRESS CHANGE
EDIT DIRECTION
HOLD BUTTONS TO ENTER/EXIT
THEIR ASSOCIATED MENU
USE ARROWS TO NAVIGATE
*
SIMPLEX MULTIPLEXERS SHOW “DISP/REC”.
PRESS THE “LIVE/VCR” KEY ON THE KEYBOARD.
Figure 10. Help Menu
Pelco Manual C581M-B (1/04)
31
MULTIPLE CAMERA DISPLAY SETUP
The multiple camera display formats may be configured using the keyboard. The LEDs
above the camera buttons on the multiplexer will illuminate to indicate which cameras are
being displayed.
PROGRAMMING THE PICTURE-IN-PICTURE DISPLAY
(
Key)
The on-screen location and size of the picture-in-picture (PIP) display are programmable.
PIP is not available in duplex VCR playback or in simplex RECORD mode.
To program the PIP display:
1. Press the MAIN MONITOR key.
2. Use the number keypad to enter the address of the multiplexer (1-16 if the keyboard is
connected to a multiplexer; 1-8 if the keyboard is connected to a server), then press
the UNIT key.
3. Press the
key.
4. Press the
key for approximately three seconds until the message PROGRAM PIP
SIZE appears.
5. Use the pan/tilt keys to increase or decrease the PIP display size.
6. Press the
key for approximately three seconds until the message PROGRAM PIP
POSITION appears.
7. Use the pan/tilt keys to move the PIP display location.
8. Press and hold the
key to exit the PIP programming menu.
PROGRAMMING THE 4-CAMERA DISPLAY (
Key)
You can program four groups of four cameras each. Each of the four groups can be pro-
grammed to include any four cameras.
is not available in simplex RECORD mode.
To program the four-camera displays:
1. Press the MAIN MONITOR key.
2. Use the number keypad to enter the address of the multiplexer (1-16 if the keyboard is
connected to a multiplexer; 1-8 if the keyboard is connected to a server), then press
the UNIT key.
3. Press the
key to call up a four-camera display. If necessary, press the
key
again to advance to the four-camera group that you wish to configure.
4. Press the
key for approximately three seconds. A bar will appear in the first
camera location of the four-camera display, indicating that you are in the programming
mode.
5. Use the pan/tilt keys to move to each camera location in the four-camera display.
6. When the camera location that you desire is highlighted, choose the new camera by
pressing the number key for the desired camera and then pressing the CAM key.
7. To exit the programming mode, use the pan/tilt keys to move the bar off the screen.
8. If necessary, repeat steps 1-5 to program another group.
32
Pelco Manual C581M-B (1/04)
PROGRAMMING THE 9-CAMERA DISPLAY (
Key)
You can program two groups of nine cameras each. Both groups can be programmed to
include any nine cameras. is not available in simplex RECORD mode.
To program the nine-camera displays:
1. Press the MAIN MONITOR key.
2. Use the number keypad to enter the address of the multiplexer (1-16 if the keyboard is
connected to a multiplexer; 1-8 if the keyboard is connected to a server), then press
the UNIT key.
3. Press the
key to call up a nine-camera display. If necessary, press the
key
again to advance to the other nine-camera group.
4. Press the
key for approximately three seconds. A bar will appear in the first
camera location of the nine-camera display, indicating that you are in the programming
mode.
5. Use the pan/tilt keys to move to each camera location in the nine-camera display.
6. When the camera location that you desire is highlighted, choose the new camera by
pressing the number key for the desired camera and then pressing the CAM key.
7. To exit the programming mode, use the pan/tilt keys to move the bar off the screen.
8. If necessary, repeat steps 1-5 to program the second group.
PROGRAMMING THE 16-CAMERA DISPLAY (
Key)
is not available in simplex RECORD mode.
To program the 16-camera display:
1. Press the MAIN MONITOR key.
2. Use the number keypad to enter the address of the multiplexer (1-16 if the keyboard is
connected to a multiplexer; 1-8 if the keyboard is connected to a server), then press
the UNIT key.
3. Press the
key to call up the 16-camera display.
4. Press the
key for approximately three seconds. A bar will appear in the first
camera location of the 16-camera display, indicating that you are in the programming
mode.
5. Use the pan/tilt keys to move to each camera location in the 16-camera display.
6. When the camera location that you desire is highlighted, choose the new camera by
pressing the number key for the desired camera and then pressing the CAM key.
7. To exit the programming mode, use the pan/tilt keys to move the bar off the screen.
Pelco Manual C581M-B (1/04)
33
PROGRAMMING MENU DEFAULTS
Table E. Programming Menu Defaults
Menu
Item
Default
System Setup
Time Display
Title Display
On
On
Normal Record Speed
2/6/8 Hr (NTSC/EIA)
3 Hr (PAL/CCIR)
2/6/8 Hr (NTSC/EIA)
3 Hr (PAL/CCIR)
Composite
High Resolution
75 Ohm
Opened
Alarm Record Speed
Main Monitor Video (Duplex Only)
Main Monitor Display
Reset All Video Terminations To
Reset All Alarm Inputs to Normally
Reset All Seq Dwell Rates To
Reset Activity Detection All Ch To
02
Enabled
Advanced System
Setup
Date Format
MM-DD-YY (NTSC/EIA)
DD-MM-YY (PAL/CCIR)
Password
Disabled
System Password
Front Panel Control
Main Monitor Display Responds To
Spot Monitor Display
Responds To
3916
Enabled
None
Sequence
Alarms
Aux Monitor Display (Duplex Only)
Responds To (Duplex Only)
Camera Types
Blank
Activity
All Color (All B/W for monochrome)
Unit ID
001
Comm. Type
Master (KBD-T/D) (Simplex)
Slave (Duplex)
Relay Output
Alarm
Record Setup
Normal Rec. Speed
Alarm Rec. Speed
2/6/8 Hr (NTSC/EIA)
3 Hr (PAL/CCIR)
2/6/8 Hr (NTSC/EIA)
3 Hr (PAL/CCIR)
Universal
VCR Type
VCR Video Format
VCR Switch Pulse
Record Alarms
Alarm Record Time
Playback Format
Composite
Disabled
As A Priority
Alarm Duration
Pelco
Custom VCR
Setup
Normal Record Speed
2/6/8 Hr (NTSC/EIA)
3 Hr (PAL/CCIR)
003
2/6/8 Hr (NTSC/EIA)
3 Hr (PAL/CCIR)
003
Normal Switch Interval
Alarm Record Speed
Alarm Switch Speed
Camera
Title
Camera Number
75 Ohm
Open
Extended (Simplex)
Off (Duplex)
Enabled
Video Input Termination
Alarm Input Normally
Coaxitron® Format
Activity Detection
Activity Detection
Sequence
Sensitivity
Activity Boxes
Med
Set All
Individual Camera Dwell Time
Quad (2x2) Dwell Time
Nine (3x3) Dwell Time
02
04
04
34
Pelco Manual C581M-B (1/04)
PROGRAMMING A PRESET
1. Press the MAIN or SPOT MONITOR key. The green LED over the MAIN or SPOT key
lights. When using the MAIN MONITOR, the SPOT MONITOR DISPLAY menu item in
the Advanced System Setup menu must be set to TRACK MAIN (refer to the
Advanced System Setup section).
2. Select the camera.
NOTE: The LEDs above
the camera buttons on the
multiplexer will illuminate to
indicate which cameras are
being displayed.
Addressing by Multiplexer (Switch 7 OFF)
a. On the number pad, press the address number of the multiplexer (1-16 if the
keyboard is connected to a multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key. The LED displays the address.
b.
On the number keypad press the number of the camera (1-16), then press the
CAM key.
Addressing Consecutively (Switch 7 ON)
On the number keypad press the number of the camera, then press the CAM
key. Refer to Table C for camera numbers.
3. Position the camera using the pan/tilt and lens keys.
4. On the number keypad press the number of the preset, then hold down the
PRESET key for five seconds.
PROGRAMMING A PATTERN
1. Press the MAIN or SPOT MONITOR key. The green LED over the MAIN or SPOT key
lights. When using the MAIN MONITOR, the SPOT MONITOR DISPLAY menu item in
the Advanced System Setup menu must be set to TRACK MAIN (refer to the
Advanced System Setup section).
2. Select the camera.
NOTE: Refer to your dome
or pan and tilt system
manual for information on
the number of available
patterns and pattern
durations.
Addressing by Multiplexer (Switch 7 OFF)
a. On the number pad, press the address number of the multiplexer (1-16 if the
keyboard is connected to a multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key. The LED displays the address.
b.
On the number keypad press the number of the camera (1-16), then press the
CAM key.
Addressing Consecutively (Switch 7 ON)
On the number keypad press the number of the camera, then press the CAM key.
Refer to Table C for camera numbers.
3. On the number pad, press a number key for the pattern number. Example: If you are
programming pattern 1 press the number 1 key. Then hold down the PATTERN key
until the message PROGRAMMING PATTERN appears on the screen.
4.
Move the camera through the pattern using the pan/tilt and lens keys.
5. To stop programming the pattern, repress the number key for the pattern followed by
the PATTERN key. Example: Press number 1 and then the PATTERN key if you are
programming pattern 1. The message PROGRAMMING PATTERN disappears.
Pelco Manual C581M-B (1/04)
35
TROUBLESHOOTING
If you have difficulty operating your system, run through the following checklist to see if you
can solve the problem.
1. Are the keyboard switches set properly?
2. Is the equipment wired properly?
3. Are the menu options in the multiplexer(s) and server set properly?
4. Has the multiplexer been set to the correct mode for live video or tape playback?
5. Only the main monitor displays multiple screen images. The spot monitor displays full
screen views only.
6. Patterns, presets, and auxiliaries will work in both MAIN and SPOT MONITOR. When
using the MAIN MONITOR, the SPOT MONITOR DISPLAY menu item in the Advanced
System Setup menu must be set to TRACK MAIN.
7. The auxiliary monitor (duplex multiplexer only) is controlled by programming. You
cannot control it from the keyboard or from the front panel of the multiplexer.
8. Tape playback can be done only on the main monitor (in VCR mode).
9. Moveable cameras must be Coaxitroncompatible and the proper Coaxitron format se-
lected in the Camera menu of the multiplexer. If the proper format is not selected, the
camera will either not move or have sluggish control.
10. Moveable cameras can be operated with the pan/tilt keys only if SPOT MONITOR is
chosen or if the spot monitor is programmed to track the main monitor. The camera
will move on the main monitor if the same camera is being shown on both the main
and spot monitors.
11. The position of switch 7 on the keyboard determines how you call cameras.
If the switch is ON, all cameras are addressed consecutively. Do not count just the
cameras installed. Count 16 camera inputs per multiplexer, even if a multiplexer has
only 9 inputs. The first input of multiplexer 1 is always camera 1, the first input of
multiplexer 2 is always camera 17, the second input of multiplexer 3 is always camera
34.
If the switch is OFF, cameras are addressed in groups 9 or 16 according to the
address of the multiplexer. Select a multiplexer (for example, number 3), then choose
a camera (1-9 or 1-16).
12. In the polled communication mode (switch 4 OFF), if you have one multiplexer, it must
be the master. If you have more than one multiplexer, one of them (any one) must be
the master and all the others slaves. In the non-polled mode (switch 4 ON), all
multiplexers must be slaves. Refer to the Advanced System Setup menu of the
multiplexer.
13. If you have more than one multiplexer, they must have different addresses (Advanced
System Setup menu of multiplexer).
14. If you have a server, the address of the multiplexer must correspond to the input it is
connected to on the server. For example, if the multiplexer goes to input 4 on the
server, the multiplexer must be address 4.
15. If you have a server, each keyboard must have its own address.
16. If you have a server, each keyboard controls its corresponding monitor(s). In the
SINGLE mode, keyboard 1 controls monitor 1, keyboard 2 controls monitor 2, etc.
In the PAIRED mode, keyboard 1 controls monitor 1 (main) and monitor 2 (spot), and
keyboard 3 controls monitor 3 (main) and monitor 4 (spot). In the paired mode,
keyboards 2 and 4 are not used.
17. If you have a server and cannot change between full screen and multiple screen views
on the main monitor, check the MAIN MONITOR CONTROL setting in the Monitor
menu of the server.
36
Pelco Manual C581M-B (1/04)
18. If the UNIT ID, in the ADVANCED SYSTEM SETUP menu, is inadvertently changed at
the keyboard resulting in an uncontrollable sequencing of unit ID numbers and loss of
keyboard control:
a. Go to the multiplexer and press the down arrow button. The sequencing should
stop. Exit the menu, then return to the ADVANCED SYSTEM SETUP menu and
change the UNIT ID back to 001. Continue normal programming from the key-
board.
OR
b. If the multiplexer is remotely located away from the keyboard, wait until the
numbers sequence to the correct multiplexer unit ID number and immediately
press any pan/tilt key. The sequencing should stop. Continue normal program-
ming from the keyboard.
SPECIFICATIONS
ELECTRICAL
Input Voltage:
12 VAC or ±12 VDC
Power Consumption: 5 watts
KEYBOARD COMMUNICATION
Keyboard Interface: RS-485 (25-foot flat cable supplied)
Connector Type:
MECHANICAL
Keyboard Keypad:
Digital Display:
RJ-45 8-pin modular (female)
Mechanical
Two red seven-segment LEDs
Main/Spot
Monitor Indicators:
Two green LEDs
GENERAL
Ambient Operating
Temperature:
20° to 120°F (-7° to 49°C)
Humidity:
10% - 90% non-condensing
8.125 (W) x 7.125 (L) x 2.25 (H) inches (20.64 x 18.10 x 5.72 cm)
2.1 lb (0.97 kg)
Dimensions:
Weight:
Shipping Weight:
3 lb (1.35 kg)
Design and product specifications subject to change without notice.
Pelco Manual C581M-B (1/04)
37
38
Pelco Manual C581M-B (1/04)
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
If
a
warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following
information:
Exceptions to this warranty are as noted below:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
•
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and keyboard).
If there is a dispute regarding the warranty of a product which does not fall under the
warranty conditions stated above, please include a written explanation with the product
when returned.
Three years on Camclosure® and fixed camera models, except the CC3701H-2,
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,
which have a five-year warranty.
Method of return shipment shall be the same or equal to the method by which the item was
received by Pelco.
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series
fixed dome products.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned
for credit, and RA number if returned for repair).
•
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, including when used in
continuous motion applications.
•
•
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing
charge.
Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura™ Series distributed network-based video products.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA
number and freight should be prepaid. Ship to the appropriate address below.
•
•
One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Six months on all pan and tilts, scanners or preset lenses used in continuous motion
applications (that is, preset scan, tour and auto scan modes).
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident
are not covered under this warranty.
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are
instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from
the specific use or application made of the Products. Pelco’s liability for any claim, whether
based on breach of contract, negligence, infringement of any rights of any party or product
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for
such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused,
whether by the negligence of Pelco or otherwise.
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
REVISION HISTORY
Manual # Date
Comments
C581M
8/99
9/03
1/04
Original version.
C581M-A
C581M-B
Added Regulatory Notices section and changed power specification.
Revised per ECO #03-9291, software upgrade to increase the number of programmable patterns.
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union
regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
Pelco, the Pelco Logo, Camclosure, Coaxitron, Esprit, Genex, Intercept, Legacy, and Spectra are registered trademarks of Pelco.
Endura and ExSite are trademarks of Pelco.
© Copyright 2004, Pelco. All rights reserved.
Pelco Manual C581M-B (1/04)
39
Worldwide Headquarters
3500 Pelco Way
Clovis, California 93612 USA
USA & Canada
Tel: 800/289-9100
Fax: 800/289-9150
International
Tel: 1-559/292-1981
Fax: 1-559/348-1120
ISO9001