Perle Systems Switch RPS1620H User Manual

5500192-12  
RPS Series  
Remote Power Switches  
Models Covered:  
RPS820  
RPS830  
RPS1620H  
RPS1630H  
Quick Start Guide  
 
1. Introduction  
This Quick Start Guide describes how to set up the Perle Remote Power Switch  
(RPS) with your IOLAN Device Server. If you are using the RPS as a stand-  
alone, see the RPS User’s Guide. You can securely manage the power going to  
any electronic device through the IOLAN Device Server. For further installation  
and configuration details, please see the IOLAN SDS/SCS/STS User's Guide.  
Components  
You should receive the following components with your RPS unit:  
• Two US Power cords with IEC power connectors  
(RPS830 and RPS1630H Models Only)  
• Quick Start Guide  
• CDROM containing the RPS User's Guide and Quick Start Guide  
• Rack Mount Brackets  
• One CAT5 Cable  
• RJ-45M to RJ-45F Adapter for use with IOLAN models  
(Part No. 1100219-10)  
• RJ-45M to RJ-45F Adapter for use with IOLAN C and CM models  
(Part No. 1100320-10)  
• RJ-45F to DB-9F for connecting the RPS console port to the PC COM port  
(Part No. 1100300-10)  
You Need to Supply  
• IOLAN Device Server (if it does not have an RJ45 connector, you will need  
an adapter.)  
• External Power Cords (Europe and UK Only)  
Page 3  
 
RPS Series - Remote Power Switches; Quick Start Guide  
2. Hardware Installation  
This Quick Start Guide assumes that you have already powered up your IOLAN  
Device Server according to the Device Server's Quick Start Guide.  
2.1. Applying Power to the RPS  
Refer to power rating nameplate on the RPS back panel, and then connect the  
RPS unit to an appropriate power source. RPS830 and RPS1630H units should  
be connected to a 100 to 120 VAC power supply, and RPS820 and RPS1620H  
units should be connected to a 208 to 240 VAC power supply.  
CAUTION: Make certain to review the safety precautions listed in  
Section 4.1 in the User's Guide and at the beginning of this Quick  
Start Guide.  
Note that RPS units feature two separate AC inputs. Connect power supply  
cables to the RPS’s Circuit "A" and Circuit "B" inlets, and then connect the  
cables to an appropriate power supply. The RPS830 and RPS1630H will support  
up to 20 Amps maximum per power circuit, for a total load of 40 Amps. The  
RPS820 and RPS1620H will support up to 16 Amps maximum per power circuit,  
for a total load of 32 Amps.  
The ON LED should light, and the RDY LED should begin to flash. This  
indicates that the RPS is ready to receive commands.  
2.2. Connecting the Device Server to the RPS  
To securely manage the RPS, configure the Device Server as follows:  
1. Set the Line Service (Profile) to Power Management for the line that is  
connected to the RPS serial port.  
2. Plug the CAT5 cable into the Console port on the RPS.  
3. Connecting the Adapter to the IOLAN:  
(a) For IOLAN Models: Plug the RJ-45M to RJ45F Adapter (Part No.  
1100219-10) into the serial port on the IOLAN that will be configued  
for Power Management. (See Section 3.)  
(b) For IOLAN Model C and CM: Plug the RJ-45M to RJ45F Adapter  
(Part No. 1100320-10) into the serial port on the IOLAN C and CM  
that will be configured for Power Management. (See Section 3.)  
4. Connect the CAT5 cable to the Adapter.  
Page 4  
 
RPS Series - Remote Power Switches; Quick Start Guide  
3. Connecting the Device Server to the RPS  
To securely manage the RPS, configure the Device Server as follows:  
1. Set the Line Service to Power Management for the line that is connected to  
the RPS serial port.  
2. Configure the Power Management Settings for the RPS.  
See the IOLAN SDS/SCS/STS User’s Guide for information about the settings  
and how to actively manage the RPS.  
4. Configuring the RPS Standalone  
To independently manage the RPS, through a PC COM port configure as follows:  
NOTE: The default serial port parameters are set as folows: 9600,  
RTS/CTS handshaking, 8 data bits, one stop bit and no parity.  
1. Plug the RJ-45F to DB9F (Part No. 1100300-10) into the COM port  
on the PC.  
2. Connect the CAT5 cable to this adapter and the RJ-45 console port  
on the RPS.  
3. Start your communication program on your PC (set serial port parameters as  
described above.)  
4. Press [Enter]  
5. The RPS will return the RPS> command prompt.  
6. Type /h to view the command menu.  
Please refer to the RPS User's Guide for instructions regarding other methods to  
connect to the RPS.  
Page 5  
 
RPS Series - Remote Power Switches; Quick Start Guide  
5. Technical Support  
Technical support information can be found at the following link:  
6. Warranty/Registration  
Details of the product warranty and registration process can be found by  
following the appropriate links on the Remote Power Switch Product page at:  
RPS Series Quick Start Guide  
Part No: 5500192-12  
Copyright © Perle Systems Limited, 2011  
Page 6  
 
FCC Part 15 Regulation  
This equipment has been tested and found to comply with the limits for a Class A digital device,  
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection  
against harmful interference in a residential installation. This equipment generates, uses, and can  
radiate radio frequency energy, and if not installed and used in accordance with the instructions, may  
cause harmful interference to radio communications. However, there is no guarantee that interference  
will not occur in a particular installation. If this equipment does cause harmful interference to radio  
or television reception, which can be determined by turning the equipment off and on, the user is  
encouraged to try to correct the interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Plug the equipment into an outlet on a circuit that is different from the one used by the receiver.  
Consult the dealer or an experienced radio/TV technician for help.  
This device complies with Part 15 of the FCC rules. Operation of this device is subject to the  
following conditions: (1) This device may not cause harmful interference, and (2) this device must  
accept any interference that may cause undesired operation.  
WARNING: Changes or modifications to this unit not expressly approved by the  
party responsible for compliance could void the user’s authority to operate the  
equipment  
EMC, Safety, and R&TTE Directive Compliance  
The CE mark is affixed to this product to confirm compliance with the following European  
Community Directives:  
Council Directive 89/336/EEC of 3 May 1989 on the approximation of the laws of Member  
States relating to electromagnetic compatibility;  
and  
Council Directive 73/23/EEC of 19 February 1973 on the harmonization of the laws of  
Member States relating to electrical equipment designed for use within certain voltage limits;  
and  
Council Directive 1999/5/EC of 9 March on radio equipment and telecommunications terminal  
equipment and the mutual recognition of their conformity.  
 
13719-C  
 

Peavey Stereo Amplifier LT Series User Manual
Philips Cassette Player AQ6681 00 User Manual
Philips Clock Radio AJ300D 37 User Manual
Philips Iron GC1015 User Manual
Philips Stereo System AZ 1025 User Manual
Pioneer Stereo Receiver D514 User Manual
Planet Technology Network Router WAP 4035 User Manual
Polar Fitness Electronics FA20 User Manual
Polycom Conference Phone 3726 17776 001 User Manual
Promise Technology Network Card SX4300 User Manual