Teledyne Power Supply HPS 10 User Manual

INSTRUCTION  
MANUAL  
MODEL HPS-10  
POWER SUPPLY  
 
Table of Contents  
1.0 General Information .............................................................................. 5  
Introduction ............................................................................................... 5  
Specifications ............................................................................................. 5  
2.0 Installation ............................................................................................... 7  
Receiving Inspection .................................................................................. 7  
Mounting.................................................................................................... 7  
Cable Connections ..................................................................................... 9  
3.0 Operating Information ........................................................................1 1  
Normal Start-up ...................................................................................... 11  
Analog Output ......................................................................................... 11  
Internal Adjustments ................................................................................ 12  
4.0 Warranty and Repair ............................................................................1 5  
page 3  
 
page 4  
 
SECTION 1  
General Information  
Introduction  
The Hastings Power Supply (HPS-10) supplies stable ±15VDC specifically for Hastings mass  
flowmeters (HFM-200 and HFM-300 series). The flowmeter returns a 0-5VDC output that is  
proportional to flow that is digitally displayed.  
Specifications  
Output voltage................................................................................................. ±15VDC ± 2.5 %  
Power input ............................................................................................. 115VAC ±10%, 50/60 Hz  
Signal input ..................................................................................................................... 0 - 5VDC  
Display ............................................................................................................................... 3½ digit  
Analog output voltage ..................................................................................................... 0 - 5VDC  
Min. load impedance ............................................................................................................. 10 kW  
Display type......................................................................................... 0.52” (13.2mm) red LEDs  
Warm up time ......................................................................................................................15 min  
Operating temperature...................................................................................................... 0 - 500C  
Load regulation.............................................................................................. ±1% (10 mA-30 mA)  
page 5  
 
page 6  
 
SECTION 2  
Installation  
Receiving Inspection  
Carefully unpack the HPS-10. Inspect all items received at this time for any obvious damage that  
may have occurred during shipment. Immediately advise the shipping agent if there is any damage  
to items in your shipment. Identify each item and the quantity received with those listed on the  
packing list.  
Mounting  
Cut out panel as shown in the diagram below.  
page 7  
 
To panel mount the HPS-10:  
1) Slide power supply into panel from the front.  
2) Attach brackets to the side of the power supply.  
3) Tighten screws against panel.  
See Figure below:  
page 8  
 
Hastings HPS-10 Power Supply Cable Connections  
The HPS-10 is supplied with a power cable.The 3-wire cable plugs into the back of the instrument  
in the socket markedAC POWER”.  
A 5-wire shielded cable connects the instrument to the flowmeter.The diagram below shows the  
proper connections.  
BLACK  
ORANGE  
YELLOW  
GREEN + SHIELD  
BLUE  
ANALOG OUT  
page 9  
 
page 10  
 
SECTION 3  
Operating Information  
Normal Start-up  
1) Connect the interface cable from the HPS-10 to the flowmeter. (See figure on page 2-4 of  
this manual)  
2) Verify that the AC power to be applied to the HPS-10 is correct (115VAC).  
3) Apply AC power to the HPS-10.  
4) The HFM instrument has a local zero adjustment. Follow the zero adjustment procedure  
described in the HFM-200 or HFM-300 series manual.  
Caution  
Before applying power to the instrument, ensure that the line voltage being  
applied is correct. Failure to do so may result in damage to the instrument  
not covered by the warranty.  
Analog Output  
The HPS-10 generates an analog signal which is directly proportional to the displayed pressure.  
The analog output signal is given by:  
DISPLAY GAS FLOW  
FLOWMETER RANGE  
V
5
OUT  
*
The output signal is a DC voltage with a full scale reading for a given flowmeter corresponding to  
+5VDC. For example, if one has a 100 sccm flowmeter with a displayed flow of 35 sccm, then the  
output voltage will be:  
35 sccm  
100 sccm  
V
5
1.75Volts  
OUT  
*
Conversely, if the analog output voltage is measured, then the gas flow reading is given by:  
V
OUT (V)*FLOWMETER RANGE  
GAS FLOW  
5
page 11  
 
Internal Adjustments  
The internal adjustments are factory set and should not be changed. However, if the need arises  
and suitable standards are available the following adjustments can be made. (see figure on page 3-4)  
Full Scale  
The full scale potentiometer changes the display by changing the sensitivity of the instrument.  
Apply a calibrated +5 VDC signal to the Sig Hi and Sig Lo pins on the back of the power  
supply.The display of the instrument should read100.0”,10.00or “1.000”depending upon the  
configuration.Adjust the full scale potentiometer (R11) if needed.  
Analog Output  
The analog output potentiometer changes the analog output voltage by changing the gain on the  
output buffer amplifier. Apply a calibrated pressure standard to the transducer and refer to  
equation (1). Adjust the potentiometer (R18) as needed.  
Notes on internal adjustments:  
*
Both the full scale reading and the analog output voltage can change by only ± 10%.  
** Zero adjustment can only be performed on the flowmeter itself. Consult your flowmeters  
manual for making these adjustments.  
Display Configuration  
The jumper position on the power supply circuit board determines the location of the decimal on  
the display.The jumper is factory set to match the configuration specified by the customer. Should  
the need arise to change the display configuration, this jumper can be easily moved (see figure on  
page 13).  
page 12  
 
configuration jumpers  
Jumper Location  
Display Configuration  
1
4
3
2
100.0  
not used  
1.000  
10.00  
page 13  
 
page 14  
 
SECTION 4  
Warranty and Repair  
Warranty Policy  
Hastings Instruments warrants this product for a period of one year from the date of shipment to  
be free from defects in material and workmanship.This warranty does not apply to defects or  
failures resulting from unauthorized modification,misuse or mishandling of the product.This  
warranty does not apply to batteries or other expendable parts, nor to damage caused by leaking  
batteries or any similar occurrence.This warranty does not apply to any instrument which has had  
a tamper seal removed or broken.  
This warranty is in lieu of all other warranties, expressed or implied, including any implied warranty  
as to fitness for a particular use. Hastings Instruments shall not be liable for any indirect or conse-  
quential damages.  
Hastings Instruments will, at its option, repair, replace or refund the selling price of the product if  
Hastings Instruments determines, in good faith, that it is defective in materials or workmanship  
during the warranty period. Defective instruments should be returned to Hastings Instruments  
together with a written statement of the problem and a Return MaterialAuthorization (RMA)  
number. Please consult the factory for your RMA number before returning any product for repair.  
Non-Warranty Repair Policy  
Any product returned for a non-warranty repair must be accompanied by a purchase order, RMA  
form and a written description of the problem with the instrument. If the repair cost is higher, you  
will be contacted for authorization before we proceed with any repairs. If you then choose not to  
have the product repaired, a minimum will be charged to cover the processing and inspection.  
Please consult the factory for your RMA number before returning any product for repair.  
TELEDYNE HASTINGS  
804 NEWCOMBE AVENUE  
HAMPTON,VIRGINIA 23669 U.S.A.  
ATTENTION: REPAIR DEPARTMENT  
TELEPHONE  
FAX  
(757) 723-6531  
1-800-950-2468  
(757) 723-3925  
page 15  
 
page 16  
 

Timex Fitness Electronics 622 095000 NA User Manual
Toastmaster Convection Oven 7091W User Manual
Toshiba CRT Television 26DF56 User Manual
Toshiba CRT Television 27A45C User Manual
Transcend Information Laptop TS32M 2GJF2B User Manual
Tricity Bendix Oven SURREY User Manual
Tricity Bendix Slow Cooker TSC6111 User Manual
Tripp Lite TV Cables P116 000 HDMI User Manual
Uniden Two Way Radio UBC3000XLT User Manual
Weber Charcoal Grill PERFORMER PLATINUM User Manual