Terraillon Personal Lift TPRO3100 User Manual

NOT_TPro_3100_v2.qxd 21/03/07 16:11 Page 2  
Notice d'utilisation  
Instruction manual  
TPRO3100  
 
NOT_TPro_3100_v2.qxd 21/03/07 16:11 Page 2  
BALANCE ÉLECTRONIQUE MÉDICALE CLASSE III  
DESCRIPTION DU PRODUIT  
Face avant  
Face arrière  
Entrée de l’adaptateur  
d’alimentation secteur  
de  
et  
Ecran LCD  
Indicateur de niveau  
Plateau  
Compartiment à piles  
Pieds réglables  
e,  
• Appareil médical de Classe I (Directive CE 93/42 EEC).  
• Conforme à la classification OIML de Classe III.  
• Conforme à la classification Instruments de Pesée Non Automatiques de Classe III (Directive CE 90/384 EEC).  
• Fonction pesée.  
• Indicateur de niveau et pieds réglables.  
• Activation par effleurement du plateau et arrêt automatique.  
• Indicateur d’alimentation.  
• Capacité : 180 kg.  
• Graduation : 100 g.  
• Alimentation : pile 9V (6LR61 ou équivalente incluse) ou via l’adaptateur d’alimentation secteur :  
Entrée AC 100-240V/ Sortie DC 9V (Adaptateur non fourni).  
Compartiment à piles  
UTILISATION DU PRODUIT  
Initialisation  
il.  
Insérer la/les pile(s) dans le compartiment à piles en respectant les polarités  
ou brancher l’appareil en le raccordant à un adaptateur d’alimentation  
secteur via une prise électrique. Le type de pile à utiliser est spécifié dans  
le compartiment à piles.  
Pile  
e :  
• Il est nécessaire de régler le niveau de l’appareil avant la première utilisation  
ou si l’appareil a été déplacé :  
1. Ne pas monter sur la balance et/ou enlever tout poids du plateau.  
2. Placer la balance sur une surface ferme et plane. Agir sur les pieds réglables pour ajuster le niveau  
de la balance jusqu’à ce que la bulle contenue dans l’indicateur de niveau apparaisse au centre du  
cercle gravé.  
de  
Indicateur de niveau  
Cercle  
ue  
e.  
Bulle  
X
2
 
NOT_TPro_3100_v2.qxd 21/03/07 16:11 Page 3  
BALANCE ÉLECTRONIQUE MÉDICALE CLASSE III  
Fonctionnement  
De  
Th  
Pl  
1. Appuyer légèrement sur la partie inférieure du cadran du produit pour le mettre sous tension.  
Les affichages apparaissent dans l’ordre suivant :version du logiciel de la balance, tous les chiffres  
et symboles,“0.0”.  
R
Th  
M
IS  
2. Monter sur l’appareil pendant que l’écran indique “0.0” et rester immobile pendant le calcul du poids.  
Le poids s’affiche automatiquement :  
A
Th  
di  
P
3. L’appareil s’éteint automatiquement environ 10 secondes plus tard.  
Affichages spéciaux  
Erreur de zéro initial.  
Descendre de l’appareil, attendre l’affichage  
0.0 et recommencer la mesure.  
Problème matériel. Contacter votre revendeur.  
Problème matériel. Contacter votre revendeur.  
Err0  
Err2  
bAtt  
adErr  
EEP  
Ustb  
Surcharge. Retirer le poids immédiatement.  
Remplacer la batterie.  
Zéro instable. Attendre que l’appareil affiche  
0.0 et recommencer la mesure.  
PROTECTION DE L’ENVIRONNEMENT  
Déposer les piles usagées dans un container prévu à cet effet pour qu’elles soient collectées et recyclées.  
Ne mélanger pas différents types de piles. Ne mélanger pas les piles usagées avec les piles neuves.  
En fin de vie, confier ce produit à un point de collecte pour le recyclage des déchets d’équipements  
électriques et électroniques.  
GARANTIE  
Ce produit est garanti contre les défauts de matériaux et de fabrication. Pendant la période de garantie, de  
tels défauts seront réparés gratuitement (la preuve d’achat devra être présentée en cas de réclamation  
sous garantie). Cette garantie ne couvre pas les dommages résultant d’accidents, de mauvaise utilisation  
ou de négligence. En cas de réclamation, contacter en premier lieu le magasin où vous avez effectué votre  
achat.  
M
SERVICE APRES-VENTE  
Pour la calibration et le service après-vente, contacter le service consommateur de Terraillon  
suivante:  
à l’adresse  
EC  
REP  
After Sales Service: Terraillon France & Headquarters  
B.P.73 -78403 Chatou Cedex-France  
Service consommateurs :0 826 88 1789  
FOOK TIN TECHNOLOGIES LTD  
4/F, Eastern Centre, 1065 Kings Road, HONG KONG  
3
 
NOT_TPro_3100_v2.qxd 21/03/07 16:11 Page 4  
INSTRUCTION MANUAL  
CLASS III ELECTRONIC MEDICAL SCALE  
Dear Customer,  
Thank you for purchasing this product. We hope you will find it satisfactory.  
Please read these instructions carefully to take full advantage of your product.  
re  
s.  
READ BEFORE USE  
The Electronic Medical Scale is designed and manufactured in a facility certified in the following  
Management Systems: ISO 9001 Quality, ISO14001 Environment, OHSAS18001 Health and Safety and  
ISO13485 Medical Devices Quality.  
Applications  
The electronic medical scale’s intended use is for weighing patients for the purposes of monitoring,  
diagnosis and medical treatment.  
Precautions of use  
This symbol indicates general precautions that should be taken when  
using this product.  
This symbol indicates the possibility of serious injury if the product is  
mishandled or instructions are ignored.  
WARNING  
This symbol indicates the possibility of physical injury or equipment  
damage if instructions are ignored.  
CAUTION  
Warning  
• Use the product on a firm and flat surface.  
• Clean after use with a lightly dampened cloth without allowing any water to get into the device. Do not  
use solvents or immerse the product in water.  
• Avoid excessive impact or vibration to the unit, such as dropping the product onto the floor.  
• Do not jump on the weighing platform.  
s.  
ts  
Only use the adaptor which has the characteristics mentioned in the paragraph: Product Specification.  
Caution  
• Do not disassemble the scale as incorrect handling may cause injury.  
de  
on  
on  
re  
MAINTENANCE  
• The product has been manufactured and calibrated with precision. The user should not disassemble or  
attempt to calibrate the product on its own.  
• Remove batteries if the product is not in use for an extended period.  
se  
4
 
NOT_TPro_3100_v2.qxd 21/03/07 16:11 Page 5  
CLASS III ELECTRONIC MEDICAL SCALE  
O
1.  
PRODUCT SPECIFICATION  
Front view  
Back view  
DC adaptor input  
Battery compartment  
Adjusting feet  
2.  
LCD display  
Level indicator  
Platform  
3.  
• Class I medical device (EC Directive 93/42 EEC).  
• Class III OIML compliant.  
W
• Class III Non-Automatic Weighing Instruments (EC Directive 90/384 EEC) compliant.  
• Weighing function.  
• Level indicator and adjusting feet.  
Tap-on and auto-off functions.  
• Low-battery indicator.  
• Capacity: 180 kg.  
• Graduation: 100 g.  
• Operates through 1 piece 9V battery (6LR61 or equivalent included) or with AC 100-240V adaptor  
adaptor output (adaptor not included).  
input/DC 9V  
Battery compartment  
PRODUCT USAGE  
Initialisation  
P
D
di  
• Insert the battery(s) in the battery compartment, making sure that the  
polarities are correct or power up the product by connecting the DC adap-  
tor to the power socket. The battery type is specified inside the battery  
compartment.  
Battery  
• Il is necessary to set the balance of the product before you use it for the  
first time or if the product has been moved to another place:  
1. Do not step on the scale or/and remove all weight from the platform.  
G
Th  
su  
un  
ev  
2. Place the scale on a hard and flat surface. Use the adjusting feet to adjust the balance until the bubble  
inside the level indicator is located in the middle of the drawn circle.  
A
Fo  
se  
Level indicator  
Circle  
Bubble  
X
5
 
NOT_TPro_3100_v2.qxd 21/03/07 16:11 Page 6  
CLASS III ELECTRONIC MEDICAL SCALE  
Operation  
1. Tap lightly on the center of the scale beneath the display to turn it on. The following displays will  
appear in the following order:software version of the scale, all digits and symbols,“0.0”.  
2. Step on the scale while the display shows “0.0” and stand still while the weight is computing. Weight  
reading will be shown automatically:  
3. The product will turn off automatically after approximately 10 seconds.  
Warning indicators  
Initial zero error. Step off the scale, wait until  
Hardware problem.  
the scale shows 0.0 and repeat measure-  
Err0  
Err2  
bAtt  
adErr  
EEP  
Ustb  
Please contact place of purchase.  
ment.  
Hardware problem.  
Please contact place of purchase.  
Overload: remove weight immediately.  
9V  
nt  
Unstable zero. Please wait until the scale  
shows 0.0 and repeat measurement.  
Low battery indication: replace it.  
PROTECT THE ENVIRONMENT  
Dispose of used batteries in a designed container so that they can be collected and recycled. Do not mix  
different types of batteries. Do not mix new and used batteries.  
After life, dispose of this product at a designated waste recycling point.  
GUARANTEE  
This product is guaranteed against defects in materials or manufacturing. During the guarantee period, any  
such defects will be repaired free of charge (proof of purchase must be shown in the case of a complaint  
under guarantee). The guarantee does not cover damage resulting from improper use or negligence. In the  
event of a claim, first contact the shop where you purchased the product.  
le  
AFTER SALES SERVICE  
For calibration and after sales services, please contact Terraillon consumer service at the following address:  
EC  
REP  
After Sales Service: Terraillon France & Headquarters  
B.P.73 -78403 Chatou Cedex-France  
Service consommateurs :0 826 88 1789  
FOOK TIN TECHNOLOGIES LTD  
4/F, Eastern Centre, 1065 King sRoad, HONG KONG  
6
 
NOT_TPro_3100_v2.qxd 21/03/07 16:11 Page 1  
Terraillon France & Headquarters  
B.P. 73 - 78403 Chatou Cedex - France  
Service consommateurs : 0 826 88 1789  
Service Après Vente :  
Terraillon chez MGF logistique  
ZI d’Epluches - Rue des Préaux  
95310 St Ouen - l’Aumône  
Hanson (UK) Ltd  
81a Marlowes - Hemel Hempstead  
Hertfordshire, HP1 1LF - UK  
Tel: +44 (0)1442 270444 - [email protected]  
Terraillon Deutschland GmbH  
Gehlengraben 2  
22415 Hamburg - Deutschland  
Tel: +49 (0)40 53 300 600 - [email protected]  
Terraillon SpA  
Viale Sarca 45  
Milano - Italy  
Tel: +39 (0)2 66114199  
Terraillon Asia Pacific Ltd  
4/F, Eastern Centre  
1065 King’s Road  
Quarry Bay - Hong Kong  
Tel: +852 (0)2960 7288  
Terraillon Corp  
1860 Renaissance Blvd  
Sturtevant, WI 53177 - USA  
Tel: +1 (0)866 696 6066  
P/N:700351253(Rev.06.11)  
 

Tekkeon MP3 Player Accessories MP1860A User Manual
Tektronix Sprinkler PG 502 User Manual
Toastmaster Coffeemaker TCM12AW User Manual
Toro Video Game Controller DDCWP User Manual
Toshiba Projection Television 50A62 User Manual
Tripp Lite Power Supply 300VA User Manual
Tripp Lite Surge Protector D10B2 User Manual
Viking Microwave Oven RDMOR200 User Manual
VocoPro Microphone UHF 6800 User Manual
Vulcan Hart Oven VB 21 ML 052312 User Manual