i
9901
DELUXE
PROGRAMMABLE
THERMOSTATS
i
9915
i
9920
User's Manual
Menu Driven Display
Integrated Damper /
Economizer Control
Fresh Air
Control
24 VAC with Worry-Free
Memory Storage
English and Spanish Menus
110-1069
Two Year Warranty
4
Changing the Time of Day
Turning on Heating and Cooling Cycles
MONDAY
3:29 PM
MONDAY
3:29 PM
From the main screen press MENU.
From the main screen press MENU.
COOL
COOL
FAN AUTO
FAN AUTO
78.1
78.1
SET AT 78
SET AT 78
MENU
HOLD TEMP
MENU
HOLD TEMP
MENU
MENU
Use the UP or DOWN arrows to highlight DAY/TIME.
Press SELECT.
PROGRAM
DAY / TIME
Use the UP or DOWN arrows to highlight HEAT/COOL.
Press SELECT.
HEAT / COOL
FAN
FRESH AIR
DAY / TIME
HOME
USER SETTINGS
INSTALLER SETTINGS
HOME
HEAT / COOL SETTINGS
SELECT
SELECT
SET DAY & TIME
OFF
Use the UP or DOWN arrows to highlight HEAT, COOL
or AUTO. Press SELECT. The SELECT button will turn
on the desired cycle. You do not have to turn off HEAT to
turn on COOL. When HEAT or COOL or AUTO is turned
on, all others are automatically shut off. After pressing
the SELECT button, the main screen will
FRIDAY
12 PM
06
DAY
HOUR
HEAT
COOL
AUTO
Use the UP or DOWN arrow to highlight DAY, HOUR
or MINUTES. Press SET.
MINUTES
HEAT / COOL SETTINGS
HEAT
SET DAY & TIME
FRIDAY
MAIN MENU
SELECT
FINISHED
SET
automatically appear.
DAY
COOL
12 PM
31
HOUR
MINUTES
Use the UP or DOWN arrow to scroll through
the days of the week, hours or minutes.
Press SET to select desired value.
NOTE: Emergency heat is used only on the 9920i model.
NOTE: AUTO appears only if Auto Changeover is turned on in the Installer Settings.
AUTO
EMERGENCY HEAT
MAIN MENU
Press FINISHED when complete.
FINISHED
SET
SELECT
5
6
What do the LED’s below the display mean?
Fan Cycles
MONDAY
3:29 PM
The LED’s indicate when the HVAC system is activated. With a call for heating or cooling, the HEAT or COOL LED will be illuminated.
The AUX LED indicates the second stage of heating or cooling.
COOL
From the main screen press MENU.
FAN AUTO
78.1
SET AT 78
HOLD TEMP
MENU
MENU
Use the UP or DOWN buttons until FAN is highlighted. Press SELECT.
The CHECK LED is used only on the 9920i. It indicates the heat pump should be serviced by a qualified technician.
The EMER LED indicates that the emergency heat is turned on.
HEAT / COOL
FRESH AIR
DAY / TIME
FAN
HOME
SELECT
Use the UP or DOWN buttons to highlight FAN settings.
Press SELECT.
FAN MENU
FAN SETTINGS
Three choices are available:
ON will turn the fan on continuously.
AUTO will turn the fan on only
when there is a call for heating
or cooling.
INTERMITTENT will turn the fan
on for a set period of time for a
given interval. Highlight the choice
you desire and press SELECT.
FAN PROGRAM
FAN SETTINGS
ON
AUTO
MAIN MENU
SELECT
INTERMITTENT
FAN MENU
SELECT
Intermittent Fan
INTERMITTENT will turn the fan on for a set period of time for a
given interval.
INTERMITTENT FAN
ON ꢀ
TIMEꢀ
5ꢀ MIN
The thermostat will cycle the fan on for the set ON cycle. The fan will remain off for the set OFF cycle.
OFF ꢀ TIMEꢀ
20ꢀ MIN
If the HVAC system runs for a longer period than the ON cycle, the OFF cycle will start counting over
again when the system shuts off.
FAN MENU
SELECT
7
8
Temporary Temperature Adjustments
Timed Temperature Adjustments
MONDAY
3:29 PM
MONDAY
3:29 PM
COOL
COOL
FAN AUTO
Press the HOLD TEMP button. The following screen appears.
78.1
From the main screen, press the UP or DOWN button. The screen
will change to the following.
SET AT 78
FAN AUTO
78.1
SET AT 78
HOLD TEMP
MENU
HOLD SETTINGS
PERMANENT HOLD
HOLD TEMP
MENU
Press the DOWN button to highlight TEMPORARY HOLD. Press SELECT.
SET TEMPERATURE AT
TEMPORARY HOLD
VACATION HOLD
HOME
Use the UP or DOWN button to adjust to the desired
temperature. This is a temporary 3-hour hold or until
the next programmed event, whichever is shorter.
For a longer duration see page 9.
F
70 ˚
SELECT
TEMPORARILY AT
The temperature should be highlighted.
UNTIL 6:30 PM
F
Press the UP or DOWN button to adjust
70 ˚
the temperature. Press SET TEMP.
HOME
SET TEMP
UNTIL 3:50 PM
After pressing the SET
TEMP button or after 5
seconds the screen will
indicate the new setpoint
and its duration. To return
to the normal operating
program mode, press
RESUME PROGRAM.
SET AT 70°F UNTIL 6:30 PM
COOL
HOME
SET TEMP
TEMPORARILY AT
F
FAN AUTO
F
70 ˚
The time should be highlighted. Press the UP or
DOWN button to adjust the time. Press SET TIME.
70.5˚
UNTIL 3:50 PM
SET AT 70°F UNTIL 8:29 PM
RESUME
HOME
SET TIME
PROGRAM
COOL
FAN AUTO
MENU
F
°
The main screen will now indicate a TEMPORARY HOLD until the
desired time. Press RESUME PROGRAM to return to the program
operating mode.
77.0
RESUME
PROGRAM
MENU
9
10
Permanent Hold
Vacation Hold
MONDAY
3:29 PM
MONDAY
3:29 PM
COOL
COOL
From the main screen press the HOLD TEMP button. The following screen appears.
From the main screen press the HOLD TEMP button. The following screen appears.
FAN AUTO
FAN AUTO
78.1
SET AT 78
78.1
SET AT 78
HOLD TEMP
MENU
HOLD SETTINGS
HOLD TEMP
MENU
HOLD SETTINGS
The PERMANENT HOLD feature should be highlighted. If it is not, use
the UP or DOWN arrow to highlight it. Press SELECT.
PERMANENT HOLD
Use the UP or DOWN arrow to highlight the VACATION HOLD feature.
PERMANENT HOLD
TEMPORARY HOLD
VACATION HOLD
HOME
Press SELECT.
TEMPORARY HOLD
VACATION HOLD
HOME
PERMANENTLY AT
SELECT
SELECT
VACATION SETTING
F
F
Use the UP or DOWN arrow to set the temperature to
the desired level. Press SET TEMP.
70 ˚
The temperature should be highlighted. Use the UP
or DOWN arrow change to the desired temperature.
Press SET TEMP.
70 ˚
HOLD MENU
SET TEMP
PERMANENTLY SET AT 71.0°F
FOR 7 DAYS
F
COOL The main screen will now
HOLD MENU
SET TEMP
FAN AUTO
indicate a PERMANENT
HOLD. Press RESUME
PROGRAM to return to the
program operating mode.
VACATION SETTING
F
70.0˚
RESUME
The number of days should be highlighted. Use
the UP or DOWN arrow to set the length of your
vacation. Press SET DAY.
PROGRAM
MENU
70 ˚
FOR 7 DAYS
Returning to Program Mode
BACK
SET DAY
SET AT 70°F FOR 7 DAYS
PERMANENTLY SET AT 71.0°F
COOL
F
°
F
COOL
FAN AUTO
77.0
FAN AUTO
Simply press the RESUME PROGRAM button. This works from all HOLD screens.
The main screen will now indicate the VACATION settings.
Press RESUME PROGRAM to cancel and return to the
program operating mode.
70.0˚
RESUME
RESUME
PROGRAM
PROGRAM
MENU
MENU
11
12
Programming
Programming (Con’t.)
MONDAY
3:29 PM
MONDAY PROGRAM
COOL
HEAT
COOL
FAN AUTO
OCCꢀ
UNOCCꢀ 06:00Pꢀ
COPY
08:30Aꢀ
72.0ꢀ 78.0
62.0ꢀ 82.0
From the main screen press the MENU button.
The time for the first event should be highlighted. Use the UP or DOWN key to change the time.
Press SET TIME.
78.1
SET AT 78
HOLD TEMP
MENU
MENU
BACK
SET TIME
MONDAY PROGRAM
PROGRAM
Use the UP or DOWN button to highlight PROGRAM. Press SELECT.
HEAT
COOL
HEAT / COOL
FRESH AIR
DAY / TIME
OCCꢀ
08:30Aꢀ
72.0ꢀ 78.0
The heating setpoint for the first event will be highlighted. Use the UP or
DOWN key to change the desired temperature. Press SET HEAT.
UNOCCꢀ 06:00Pꢀ
62.0ꢀ 82.0
COPY
HOME
SELECT
You can select a variety of programming. Make your
selection and press SELECT. MON-SUN allows every
day to be set the same. MON-FRI allows for weekday
programming while SAT-SUN will adjust weekends differ-
ently. You also can select each day of the week individu-
ally. NOTE: Even if you select MON-SUN, you still can
go back and change individual days to suit your lifestyle.
SELECT PROGRAM DAYS
BACK
SET HEAT
MON TO SUN
MON TO FRI
SAT TO SUN
MONDAY
MONDAY PROGRAM
HEAT
72.0ꢀ 78.0
62.0ꢀ 82.0
COOL
The cooling setpoint for the first event will
be highlighted. Use the UP or DOWN key
to change the desired temperature. Press
SET COOL.
OCCꢀ
08:30Aꢀ
UNOCCꢀ 06:00Pꢀ
COPY
MAIN MENU
SELECT
MONDAY PROGRAM
Use the UP or DOWN button to
HEAT
COOL
select the event to program. The
thermostat can be selected for 2,
4, or 6 events per day. See USER
SETTINGS for EVENTS PER
BACK
SET COOL
OCCꢀ
08:30Aꢀ
72.0ꢀ 78.0
MONDAY PROGRAM
UNOCCꢀ 06:00Pꢀ
62.0ꢀ 82.0
COPY
HEAT
COOL
The second event will now be highlighted.
Use the UP or DOWN key to change events if
desired.
OCCꢀ
UNOCCꢀ 06:00Pꢀ
COPY
08:30Aꢀ
72.0ꢀ 78.0
62.0ꢀ 82.0
DAY selection. After selecting the
event to program, press SELECT.
MAIN MENU
SELECT
BACK
SELECT
Please go to the next page for a continued discussion on programming.
13
14
Copy Command
Events
MONDAY PROGRAM
An event is a programming period. This could be the period in the morning when the facility is occupied. It could be the period when
no one is at work. It could be the evening.
HEAT
COOL
OCCꢀ
08:30Aꢀ
72.0ꢀ 78.0
In the program screen, press the DOWN button until COPY is highlighted.
Press SELECT.
UNOCCꢀ 06:00Pꢀ
62.0ꢀ 82.0
The time for an event is selected based on when you want the event to occur. For example, if people start to arrive at the facility at
6:30 AM, set the first event for 6:30 AM. The thermostat will automatically make sure the environment is at the desired temperature
selected for that event by the time you desired.
COPY
NOTE: Copy command will appear only if programming an individual day.
MAIN MENU
SELECT
This thermostat can be selected for 2, 4, or 6 events.
Energy Saving Programs
COPY MONDAY TO
The thermostat is set with the US EPA ENERGYSTAR® recommended times and temperatures for optimal energy savings. You can
change these to suit your lifestyle.
Use the UP or DOWN button to highlight the
day to copy to. Press YES / NO. A YES will
appear next to the day. Do this for each day to
which that program is to be copied. Press
FINISHED when complete.
TUESDAYꢀ
WEDNESDAY
THURSDAY
FRIDAYꢀ
YES
The best rule is to examine your schedule and set the times and temperatures that best fit. This thermostat is so versatile, you can
easily temporarily change temperatures or programs at a whim.
YES
FINISHED
YES / NO
CONTINUE
PROGRAMMING?
After pressing FINISHED, you can choose to pro-
gram other days or exit. YES will take you back to
the Select Program Days screen. NO will exit you
to the main screen.
NOꢀꢀ
YES
15
16
Setting the Economizer / Damper Program
User Settings
MONDAY
3:29 PM
MAIN MENU
The thermostat can be set to open or close a damper or economizer at different times during the day. To
program this setting, select FRESH AIR from the main menu and press SELECT.
COOL
HEAT / COOL
DAY / TIME
FAN
The USER SETTINGS can change the way information is displayed on the thermostat and help
to optimize comfort. It’s one way to truly personalize your new thermostat.
FAN AUTO
78.1
SET AT 78
FRESH AIR
FRESH AIR MENU
HOLD TEMP
MENU
HOME
SELECT
Select PROGRAM. Press SELECT.
PROGRAM
PURGE CYCLE
MENU
DAY / TIME
To get to the USER SETTINGS, press the MENU button from the main screen.
FAN
FRESH AIR
MAIN MENU
SELECT
FRESH AIR PROGRAM
MON TO SUN
WEEKDAY
WEEKEND
MONDAY
Programming is just like the temperature program. The
time of the events is determined from the setting in the
TEMPERATURE PROGRAM MENU.
USER SETTINGS are below the FAN settings. Use the DOWN button to scroll below the
screen. Press SELECT.
USER SETTINGS
HOME
SELECT
FRESH AIR MENU
SELECT
WEEKDAY F / A PROGRAM
Using the UP or DOWN
Choose the setting you would like to change. When the SETTING is highlighted, press SELECT. There are 13 USER
SETTINGS in all as listed below. For detailed information on each user setting, please go to the next page.
arrow, select OPEN or
ꢀꢀ
DAMPER
OCCꢀ
08:00AMꢀ OPEN
CLOSED for each event.
UNOCCꢀ
10:00PMꢀ CLOSED
USER SETTINGS MENU
OR Cꢀ
USER SETTINGS MENU
USER SETTINGS MENU
COOLING LIMITꢀ
USER SETTINGS MENU
HEATING LIMITꢀ
BACK
SELECT
Setting the Purge Cycle
1ST STAGE DIFFꢀ
2ND STAGE DIFFꢀ
2ND STAGE DELAYꢀ
COOLING LIMITꢀ
1˚F
2˚F
F
˚F
12
68˚F
78˚F
78˚F
ENG
L & R
OFF
12 OR 24hrꢀ
HEATING LIMITꢀ
LANGUAGEꢀ
LANGUAGEꢀ
20
SHOW SET TEMPꢀ
EVENTS / DAYꢀ
YES
4
ENG
L & R
SENSOR SELECTꢀ
SECURITYꢀ
PURGE CYCLE
During periods when the facility may be unoccupied, the thermostat can open the damper or economizer
to bring in fresh air for short periods of time. To set, simply select PURGE CYCLE from the FRESH AIR
MENU and press SELECT.
45˚F
SENSOR SELECTꢀ
ꢀ OPEN TIMEꢀ
5ꢀ MIN
SELECT
MAIN MENU
SELECT
MAIN MENU
SELECT
MAIN MENU
SELECT
ꢀ
CLOSED TIMEꢀ
2ꢀ HR
MAIN MENU
Using the UP and DOWN buttons, change the desired open time and close time for the damper.
To disable this function, set the OPEN TIME to 0. The word OFF will appear.
NOTE: This function will operate only when the damper is closed during an event.
FRESH AIR MENU
SELECT
17
18
Detailed Information on the USER SETTINGS
More Detailed Information on the USER SETTINGS
To select a USER SETTING, use the UP or DOWN button to highlight the desired value. Press SELECT to select desired value.
DIFFERENTIAL SETTINGS
DIFFERENTIAL SETTING
The temperature differential is your comfort level. The differential is the difference from setpoint
before your heating or cooling system will turn on. The 9915i and 9920i models also have 2nd
stage differential. If the temperature falls below (or above for cooling) the setpoint by the 1st stage
differential plus the 2nd stage, the auxiliary heating (or cooling) system will turn on.
1ST DIFFꢀꢀ
1˚F
TEMPERATURE
2ND DIFFꢀꢀ
2ND DELAYꢀꢀ
2˚F
TEMPERATURE: Fahrenheit or Celsius
Temperature will be displayed in F or C.
˚F
20 MIN
˚C
USER MENU
SELECT
The 2nd stage delay is a timed delay before the second stage will turn on if the setpoint has not
been achieved within that time frame.
USER MENU
CLOCK
SELECT
CLOCK SETTINGS
Displays time in standard 12-hour format or military format.
12 HOUR
24 HOUR
HEATING and COOLING LIMITS
SET COOLING LIMIT
SET HEATING LIMIT
To prevent individuals from adjusting the thermostat too hot or too
cold, you can limit the maximum setting for the heating and cooling
modes. This will help you save on energy costs.
LOWEST COOLINGꢀ
SETTING ALLOWED
45 °F
HIGHEST HEATINGꢀ
SETTING ALLOWED
90 °F
USER MENU
SELECT
DISPLAY SET POINT
TEMPERATURE ?
USER MENU
SELECT
USER MENU
SELECT
SETPOINT TEMPERATURE
Each event has a setpoint temperature. Choose whether to display this value or not.
NO
YES
USER MENU
SELECT
LANGUAGE SETTING
This screen allows you to choose the displayed language; English or Spanish.
SELECT A LANGUAGE
ENGLISH
SELECT EVENTS / DAY
EVENTS / DAY
4
ESPANOL
NUMBER OF EVENTS PER DAY
Select events per day. Choose from 2, 4, or 6 events per day.
˜
USER MENU
SELECT
0
6
12
18
SELECT
24
USER MENU
19
20
INSTALLER Settings
More Detailed Information on the USER SETTINGS
The INSTALLER SETTINGS are set during the initial installation. They tell the thermostat how to function with your heating or
cooling equipment. The following is a brief overview and discussion of these settings.
SENSOR SETTINGS
SENSOR SETTINGS
This screen will appear when a remote indoor sensor (9020i) is connected to the thermostat.
USE LOCAL SENSOR
AVG. LOCAL / REMOTE
USE REMOTE SENSOR
USE LOCAL SENSOR will disable the remote sensor and only sense from the thermostat.
INSTALLER SETTINGS
SYSTEM SETUPꢀ GAS
INSTALLER SETTINGS
INSTALLER SETTINGS
CONTACT INFO
INSTALLER SETTINGS
SHORT CYCLEꢀ
AVG. LOCAL/REMOTE will take a temperature reading from both the thermostat and the remote
sensor and average the two for even temperature control. USE REMOTE SENSOR will disable
the sensor in the thermostat and only control from the remote location.
OFF
AUTOCHANGEOVERꢀ
OFF
EERꢀꢀ
ON
RESIDUAL COOLꢀ
LOW BALANCEꢀ
HIGH BALANCEꢀ
60
SERVICE INT
REMINDERꢀ
USER MENU
SELECT
DEADBANDꢀꢀ
3˚F
45˚F
95˚F
RUN
SECURITYꢀꢀ
OFF
TEMP OFFSETꢀ
3.0˚F
SECURITY SETTINGS
MAIN MENU
MAIN MENU
SELECT
MAIN MENU
SELECT
SELECT
MAIN MENU
SELECT
SECURITY
In order to prevent tampering with the program and desired settings, two levels of security are avail-
able.The first will allow only temporary changes to the temperature. It protects all other
programmed setpoints. The second will restrict changes to EVERYTHING, including temporary
changes to the temperature.
CHANGE TEMP. ONLY
PREVENT ALL CHANGES
SYSTEM SETUP
USER MENU
SELECT
FURNACE
SYSTEM SETUP
The 9901i has a furnace or heat pump system selection.
HEAT PUMP
SECURITY CODE
ENTER SECURITY CODE
FOR TEMPERATURE
In this screen you enter a four-digit code. Use the UP or DOWN button to change the first value,
press SELECT. The second digit will be highlighted. Repeat for all four values. And don’t forget your
code. If you do, you will have to reset the entire thermostat and that will erase all the schedules
you’ve programmed into the unit.
INSTALL MENU
SELECT
0
0
0
0
1ST STAGE HEATING
GAS / OIL
USER MENU
SELECT
1st STAGE HEATING
The 9915i can have a gas/oil or electric first stage heating.
Choose the energy source for 1st stage heating.
ELECTRIC
Changing USER Settings
About the only features you may need to change are the temperature differentials (if you desire additional comfort), and the security
settings. All the other settings probably will not need to be changed.
INSTALL MENU
SELECT
21
22
INSTALLER settings (continued)
INSTALLER settings (continued)
AUXILIARY HEAT
ENERGY EFFICIENT
RECOVERY
AUXILIARY HEAT
ENERGY EFFICIENT RECOVERY
When turned on, the thermostat will look up to two hours before the next event and anticipate when
to turn on to reach the desired temperature.
STANDARD - COMP. =ON
ADD ON - COMP. =OFF
DISABLE
ENABLE
The 9920i can be set to use your 2H/2C heat pump internal auxiliary heating or to use an exter-
nal add-on source. The add-on feature will be used most often when a single stage heat pump
uses a gas or electric furnace as its second stage of heating.
INSTALL MENU
SELECT
INSTALL MENU
SELECT
RESIDUAL COOL
AUTOCHANGE DEADBAND
DEADBAND SETPOINT
RESIDUAL COOL
Deadband is used with the AUTO CHANGEOVER feature. The deadband is the temperature
difference from the setpoint temperature during which the heating or cooling will not be turned on.
This is adjustable from 2-8°F (1.0-4°C).
SECONDS DELAY
60
3 ˚F
In order to get greater efficiency from the cooling system, the fan can be programmed to run for
0 (OFF), 30, 60, 90, or 120 seconds after the air conditioner has shut off.
INSTALL MENU
SELECT
INSTALL MENU
SELECT
ENTER SECURITY CODE
FOR INSTALLER
SETTINGS
BALANCE POINTS
LOW BALANCEꢀ
BALANCE POINTS
This screen will appear only when the optional outdoor sensor 9025i is connected to the
thermostat. When this sensor is used with the 9920i, you can set the lower temperature (below
which the heat pump will not run) and upper temperature (above which the 2nd stage heat will not
run). This promotes efficient operation of the heating system.
SECURITY CODE
Enter a code to prevent changes to the INSTALLER settings.
45 ˚F
HIGH BALANCEꢀ
95 ˚F
0
0
0
0
INSTALL MENU
SELECT
INSTALL MENU
SELECT
CONTACT INFORMATION
AUTO CHANGEOVER
AUTO CHANGEOVER
AIR EXPERTS
1-555-555-1212
CONTACT INFORMATION
This allows the servicing HVAC contractor to put their name and phone number into the thermostat
to remind you when service may be required.
DISABLEꢀ
When turned on, the thermostat will switch automatically between heating and cooling to maintain
the optimal temperature in your home.
ENABLE
BACK
EDIT
INSTALL MENU
SELECT
23
24
SERVICE MONITOR MENU
SERVICE MONITOR MENU
Changing INSTALLER Settings
The INSTALLER SETTINGS are selected based on the type of equipment you have in your facility. This feature should be set only by
a certified HVAC technician. Changing these settings could result in higher energy costs and may even damage the equipment. You
should only change the FILTER MONITOR length should you get a new type of filter.
Two menus are available for the 9920i, the Service Monitor and the Filter Monitor. Three menus are
available for the 9901i and the 9915i, the Cool Monitor, the Heat Monitor and the Filter Monitor. All
can be set based on the HVAC system run time or the calendar. See Reminder Interval.
All selections can be set from OFF to 360 days in 30 day increments or OFF to 980 in 20 hour increments.
COOL MONITOR 980
HEAT MONITOR 980
FILTER MONITOR 980
INSTALL MENU
SELECT
REMINDER INTERVAL
REMINDER PERIOD
Energy Efficient Recovery™ (EER™)
The Reminder Interval can be set for either HVAC system run time or based on the calendar.
If Run Time is chosen, the service reminder will be set in hours. After the HVAC system has been
operating for the selected number of hours, a Service Reminder will be displayed informing you that
service is suggested for your system.
Energy Efficient Recovery™ is an energy saving feature. During a set back period (or set up in cooling), it allows the thermostat to
look up to two hours ahead to determine when to turn on the heating (cooling) system. During this time period, the second stage is
locked out to allow the first (and most efficient stage) to bring your facility to the desired temperature.
RUN TIME
CALENDAR TIME
If Calendar Time is chosen, the service reminders will be set in days. After the selected number of
days has passed, a Service Reminder will be displayed informing you that service is suggested for
your system.
INSTALL MENU
SELECT
Indoor Sensor
The remote indoor sensor (part #9020i) can be used to improve the comfort of your home. When used in conjunction with the local
sensor on the thermostat, the two sensors average the sensed temperature and control to that average temperature.
TEMPERATURE OFFSET
TEMPERATURE OFFSET
You also can use the remote sensor in a stand-alone situation when you want to control the temperature in a remote area but have the
thermostat in a secure location.
The last unique feature is the OFFSET or calibration feature. This allows the installer to recalibrate
the thermostat if the displayed room temperature is not the actual room temperature. The OFFSET
feature also allows you to display a temperature that is different from the actual room temperature.
+3.0 ˚F
Outdoor Sensor
INSTALL MENU
SELECT
The remote outdoor sensor (part #9025i) can be used to aid in the comfort of your facility or simply as a sensing device to inquire
about outdoor conditions. In most applications, the thermostat will have a display of the temperature sensed by the remote outdoor
sensor. With a heat pump system, the remote outdoor sensor can help determine when to turn on the second stage of heating for opti-
mal comfort. The remote outdoor sensor should be installed on the northern wall of the facility, away from direct sunlight or other heat
sources that may affect its sensitivity.
SHORT CYCLE PROTECTION
SHORT CYCLE
PROTECTION
You can change or remove the timed delay that protects the compressor in an air conditioner or
heat pump system. Short Cycle Protection should be turned off ONLY if the HVAC system has other
protective circuits that guarantee a compressor off time. This feature is adjustable from OFF to 5
minutes in 1-minute increments.
4
MINUTES
INSTALL MENU
SELECT
25
26
TWOYEAR LIMITED WARRANTY
Additional Information
The manufacturer warrants to the original contractor installer or to the original consumer user, each new
Robertshaw thermostat to be free from defects in materials and workmanship under normal use and serv-
ice for a period of two (2) years from the date of purchase.
call at 800-445-8299.
This warranty does not cover batteries (if so equipped), damage caused by batteries, damage resulting
from improper installation, alteration, misuse or abuse of the thermostat occurring after the date of pur-
chase.
The manufacturer agrees to repair or replace at its option any thermostat under warranty provided it is
returned within the warranty period, postage prepaid, with proof of the date of purchase. Cost of thermo-
stat removal or reinstallation is not the responsibility of the manufacturer.
Repair or replacement as provided under this warranty is the exclusive remedy of the consumer.This war-
ranty and our liability does not apply to merchandise that has been damaged caused by misuse, neglect,
mishandling, alterations, improper installation, or use in a way other than in accordance with the recom-
mendations and instructions of the manufacturer. Except to the extent prohibited by applicable law, any
implied warranty of merchantability or fitness for a particular purpose on this product is limited to the dura-
tion of this warranty.
Power Outage Protection
The thermostat automatically retains the time of day for approximately two hours in the event of a power outage. All other programmed
parameters are stored permanently in memory. So, if the power is out for more than two hours, simply reset the clock. See page 4.
Resetting to Factory Conditions
To reset the thermostat to factory conditions, press the UP button and the LEFT button at the same time. Hold for 8 seconds. The time
of day will display 12:00 indicating a reset has occurred.
NOTE: This will erase all programming and return the thermostat to the factory conditions including the installer settings. Use this
only as a last resort.
Some states do not allow the exclusion or limitation of incidental or consequential damages, or allow limi-
tations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to
state.
Instructions for return:
Pack the thermostat carefully in a well-padded carton. Be sure to include a note describing, in detail, what
is wrong with the product. Return, postage prepaid, to: Climate Controls Americas 515 South
Promenade Ave., Corona, CA 91719, Attn: Warranty Department