Transcend Information Computer Hardware TS4GSDOM22H User Manual |
22P Horizontal Type
SATA Flash Modules
TS4GSDOM22H
Description
Features
Serial-ATA is designed as a successor to the
legacy SATA standard. The new standard is
dedicated to achieve higher transfer rate with thinner
cables and more reliable operation than Parallel ATA
interface. SATA Flash Modules is perfect
replacement storage device for PCs, Laptops,
gaming systems, and handheld devices.
•
•
RoHS compliant
Fully compatible with devices and OS that support the
SATA 1.0a 1.5Gbps standard
•
Non-volatile Flash Memory for outstanding data
retention
•
•
Supports up to Ultra DMA Mode 4
Built-in ECC (Error Correction Code) functionality and
wear-leveling algorithm ensures highly reliable of data
transfer
Placement
•
•
•
7P Signal + 15P Power male SATA connector
Low Power Consumption
Shock resistance
Dimensions
Side
A
Millimeters
44.00 ± 0.15
33.57 ± 0.15
10.98 ± 0.20
Inches
1.732 ± 0.006
1.322 ± 0.006
0.432 ± 0.008
B
C
* Please refer to Mechanical Drawing
1
Transcend Information Inc.
V1.1
22P Horizontal Type
SATA Flash Modules
TS4GSDOM22H
Reliability
Built-in 4 symbol/page correction ECC
10 years
Data Reliability
Data Retention
Connector Durability
500 mating cycles
Performance
Model P/N
Read (KB/s)
Write (KB/s) Random Read (KB/s) Random Write (KB/s)
18050 46778 5678
47473
4GB SATA Flash Module
* Note : The performance is based on Samsung K9KAG08U0M, dual channel. Environment: at 25 ℃, tested with
GA-8IG1000MK, 256 MB RAM, SATA interface support UDMA4, Windows® XP Version 2002 SP2, benchmark utility :
HDBENCH (version 3.4006), copied file 100MB
Actual Capacity
Model P/N
Capacity
C/H/S
Capacity (BIOS) DOS Format (Bytes) Windows Format (Bytes)
4GB SATA Flash
Module
4GB
7769 / 16 / 63
4009MB
4,001,169,408
4,001,169,408
* Note: FAT32 format
Regulations
Compliance
CE, FCC and BSMI
3
Transcend Information Inc.
V1.1
22P Horizontal Type
SATA Flash Modules
TS4GSDOM22H
Mechanical Drawing
C
B
A
(Normal Type)
(Reversed Type)
4
Transcend Information Inc.
V1.1
22P Horizontal Type
SATA Flash Modules
TS4GSDOM22H
Pin Assignments
Pin No.
Pin Name
Pin No.
Pin Name
01
03
05
07
09
11
13
15
17
19
21
GND
A-
02
04
06
08
10
12
14
16
18
20
22
A+
GND
B+
B-
GND
NC
NC
NC
GND
GND
5V
GND
5V
5V
GND
GND
NC
GND
NC
NC
Pin Layout
Pin 1
5
Transcend Information Inc.
V1.1
22P Horizontal Type
SATA Flash Modules
TS4GSDOM22H
Block Diagram
Data bus
D0 ~ D7
Flash Memory
Data
bus
PATA
to
-CE0, -CE1…
Others
Control
Signal
D0 – D7
-CE0 ~ -CE3
-WE…-RE
SATA
Bridge
IDE / PATA
Flash Disk
Controller
Flash Memory
D8 ~ D15
D8 – D15
-CE0 ~ -CE3
-WE…-RE
5V/3.3V
3.3V/1.8V
Voltage
-CE0, -CE1…
Regulator
Flash Memory
DC Characteristics
Parameter
Symbol
Min.
Max.
5.5
Unit
Remark
Supply Voltage
VCC
VOH
VOL
VIH
2.97
V
High level output voltage
VCC – 0.8
V
Low level output voltage
0.8
V
V
2.4
Non-schmitt trigger
Schmitt trigger1
High level input voltage
2.05
V
VIL
0.6
1.25
141
172
V
Non-schmitt trigger
Schmitt trigger1
Low level input voltage
V
Pull up resistance2
RPU
RPD
52.7
47.5
KOhm
kOhm
Pull down resistance
6
Transcend Information Inc.
V1.1
22P Horizontal Type
SATA Flash Modules
TS4GSDOM22H
Command Set
Command
Code
E5 or 98h
90h
FR
–
SC
–
SN
–
CY
–
DH
Y
LBA
–
Status
Support
Note
1
2
3
4
5
6
7
8
9
Check Power Mode
Execute Drive Diagnostic
Erase Sector
–
–
–
–
Y
–
Support
Not Support
Support
Support
Support
Support
Support
Support
C0h
–
Y
–
Y
–
Y
–
Y
Y
–
#3
Flush Cache
E7h
–
Y
Format Track
50h
–
Y
–
–
Y
–
Y
Y
–
Identify Device
Idle
ECh
–
–
Y
E3h or 97h
E1h or 95h
91h
–
Y
–
–
–
Y
–
Idle Immediate
Initialize Drive Parameters
–
–
–
Y
–
–
Y
–
–
Y
–
Key Management
Structure Read
B9 (Feature
0-127)
10
11
12
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
–
–
–
NOT Support #1
NOT Support #1
NOT Support #1
Key Management Read
Keying Material
B9 (Feature
80)
Key Management Change
Key Management Value
B9 (Feature
81)
13 NOP
00h
–
–
–
–
–
–
–
–
–
–
–
Y
–
–
–
–
Y
Y
Y
Y
Y
Y
Y
Y
Y
–
–
NOT Support
Support
14 Read Buffer
15 Read DMA
E4h
C8h
Y
Y
Y
Y
Y
–
Y
Y
Y
Y
Y
–
Y
Y
Y
Y
Support
16 Read Long Sector
17 Read Multiple
18 Read Sector(s)
19 Read Verify Sector(s)
20 Recalibrate
22h or 23h
C4h
NOT Support #2
Support
Y
Y
Y
–
20h or 21h
40h or 41h
1Xh
Support
Y
Support
–
Support
21 Request Sense
03h
–
–
–
–
–
Not Support
Support
#3
22
Security Disable Password F6h
–
–
–
–
Y
23 Security Erase Prepare
24 Security Erase Unit
25 Security Freeze Lock
26 Security Set Password
F3h
F4h
F5h
F1h
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Y
Y
Y
Y
–
–
–
–
Support
Support
Support
Support
7
Transcend Information Inc.
V1.1
22P Horizontal Type
SATA Flash Modules
TS4GSDOM22H
27 Security Unlock
28 Seek
F2h
–
–
Y
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Y
–
–
–
Y
–
–
Y
–
Y
Y
Y
Y
Y
–
Y
–
–
Y
–
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
–
Y
–
Support
Support
Support
Support
Support
Support
Support
7Xh
29 Set Feature
EFh
30 Set Multiple Mode
31 Set Sleep Mode
32 Standby
C6h
–
–
–
E6h or 99h
E2 or 96h
E0 or 94h
87h
–
–
–
–
–
–
33 Standby Immediate
34 Translate Sector
35 Wear Level
–
–
–
Y
–
Y
–
Y
–
Not Support
Support
#3
#4
F5h
36 Write Buffer
E8h
–
–
–
Support
37 Write DMA
CAh
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Support
38 Write Long Sector
39 Write Multiple
40 Write Multiple w/o Erase
41 Write Sector(s)
42 Write Sector(s) w/o Erase
43 Write Verify
32h or 33h
C5h
Not Support
Support
#2
#3
#3
CDh
Not Support
Support
30h or 31h
38h
Not Support
Support
3Ch
#1: This command is optional, depending on the key Management scheme in use.
#2: Use of this command is not recommended.
#3: CFA feature set command is not supported by P-ATA to S-ATA bridge controller.
#4: If Security command 22~27 are supported, this command is not supported.
Definitions
FR = Features Register
SC =Sector Count register (00H to FFH, 00H means 256 sectors)
SN = Sector Number register
CY = Cylinder Low/High register
DH = Head No. (0 to 15) of Drive/Head register
LBA = Logic Block Address Mode Support
– = Not used for the command
Y = Used for the command
8
Transcend Information Inc.
V1.1
22P Horizontal Type
SATA Flash Modules
TS4GSDOM22H
SMART Command Set
ꢀSMART Command Set
SMART Feature Register Values
D0h
D1h
D2h
D3h
Read Data
D4h
D8h
D9h
DAh
Execute OFF-LINE Immediate
Enable SMART Operations
Read Attribute Threshold
Enable/Disable Autosave
Save Attribute Values
Disable SMART Operations
Return Status
1. If reserved size is below the Threshold, the status can be read from Cylinder register by Return Status command
(DAh).
ꢀSMART Data Structure
BYTE
0-1
F / V
X
Decription
Revision code
2-361
362
X
Vendor specific
V
Off line data collection status
363
X
Self-test execution status byte
364-365
366
V
Total time in seconds to complete off-line data collection activity
X
Vendor specific
367
F
Off-line data collection capability
368-369
370
F
SMART capability
F
Error logging capability
7-1 Reserved
0 1=Device error logging supported
371
X
F
F
F
R
F
V
V
V
Vendor specific
372
Short self-test routine recommended polling time (in minutes)
373
Extended self-test routine recommended polling time (in minutes)
374
Conveyance self-test routine recommended polling time (in minutes)
375-385
386-395
396
Reserved
Date Code
Number of MU in device (0~n)
MU number
397+(n*6)
398+(n*6)
MU data block
9
Transcend Information Inc.
V1.1
22P Horizontal Type
SATA Flash Modules
TS4GSDOM22H
400+(n*6)
401+(n*6)
402+(n*6)
511
V
V
V
V
MU spare block
Init. Bad block
Last Defect Bad block ( Newest state)
Data structure checksum
F=the content of the byte is fixed and does not change.
V=the content of the byte is variable and may change depending on the state of the device or
the commands executed by the device.
X=the content of the byte is vendor specific and may be fixed or variable.
R=the content of the byte is reserved and shall be zero.
* 4 Byte value : [MSB] [2] [1] [LSB]
10
Transcend Information Inc.
V1.1
22P Horizontal Type
SATA Flash Modules
TS4GSDOM22H
Ordering Information
TS XG SDOM XX
Connector type
7H = 7pin SATA horizontal
22V = 22pin SATA vertical
Transcend Product
22H = 22pin SATA
horizontal
Capacity:
SATA Flash Module
1G~8G
1. The above technical information is based on industry standard data and has been tested to be reliable. However,
Transcend makes no warranty, either expressed or implied, as to its accuracy and assumes no liability in
connection with the use of this product. Transcend reserves the right to make changes to the specifications at any
time without prior notice.
2. For specific capacity, performance, and reliability requirement, please contact with sales.
USA
Los Angeles:
E-mail: [email protected]
Maryland:
E-mail: [email protected]
CHINA
E-mail: [email protected]
TAIWAN
GERMANY
E-mail: [email protected]
No.70, XingZhong Rd., NeiHu Dist., Taipei, Taiwan, R.O.C
TEL +886-2-2792-8000
Fax +886-2-2793-2222
E-mail: [email protected]
HONG KONG
E-mail: [email protected]
JAPAN
E-mail: [email protected]
THE NETHERLANDS
E-mail: [email protected]
United Kingdom
E-mail: [email protected]
11
Transcend Information Inc.
V1.1
|