User’s Guide
CPSMC0100-210
Single-Slot PointSystem™ Chassis
with Internal Power Supply
The Transition Networks CPSMC0100-210 single-slot PointSystem™ chassis is
equipped with an internal power supply, and is designed for installation of a single,
selectable Transition Networks PointSystem™ slide-in-module media converter
with a maximum of 12 Watts.
Part Number
Description
CPSMC0100-210 Single-slot PointSystem™ chassis, with an internal power
supply, intended for installation of any PointSystem™ slide-
in-module media converter up to 12 Watts.
Note: The following media converter families are not compatible with Transition
Networks CPSMC0100-210 single-slot PointSystem™ chassis: C4TEF,
CAPTF, CBFTF-120, CBFTF-140, CEMTF, CGFEG and the CMEFG.
Installation . . . . . . . . . . . . . . . . . .2
Technical Specifications . . . . . . . .5
Troubleshooting . . . . . . . . . . . . . .6
Contact Us . . . . . . . . . . . . . . . . . .7
Compliance Information . . . . . . . .8
CPSMC0100-210
Installation -- Continued
Grounding the Media Converter
Technical Specifications
For use with Transition Networks Model CPSMC0100-210 or equivalent.
The CPSMC0100-210 single-slot chassis comes equipped with grounding lugs
located on the back panel. They require a grounding conductor wire
terminated with a two-hole, compression-type, grounding connector. The
grounding wire -- which must be a copper conductor -- is not included with
the chassis and must be provided by the customer/installer.
Note: The maximum power delivery capacity for the chassis slot is 12 Watts.
Compliance
Dimensions
Weight
EN55022; CISPR 22; Class A & B; CE Mark
6.086 x 5.875 x 1.5 in (155 x 149 x 38 mm)
1.6 lbs. (0.7 kg) Approximately
The electrical conducting path from the single-slot chassis must:
Power Supply
MTBF
12VDC, 1.25 A (maximum)
•
Flow via the grounding lugs to the common bonding network (CBN) for
telecom installations, or to an alternative approved grounding system (if
required) for non-telecom installations.
49,888 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
133,257 hours (Bellcore7 V5.0)
Environment
Tmra*:
0 to 50°C (32 to 122° F )
•
•
Be of sufficiently low impedance to conduct fault currents likely to be
imposed on the media converter, and
Storage Temp: -20 to 85°C
Humidity:
Altitude:
5 to 95%, non condensing
0 to 10,000 feet
Enable proper operation of any over-current protection devices.
Warranty
Lifetime
The conductor must be fastened to the grounding lugs with the enclosed anti-
rotation star-washers and lug-nut fasteners. The applied torque required to the
connector lug-nut fasteners is specified by the connector’s manufacturer.
*Manufacturer’s rated ambient temperature.
The information contained in this user’s guide is subject to change. For the most
up-to-date information on the CPSMC0100-210 single-slot chassis, view the
Lug nuts (included)
Star washer (included)
Two-hole, compression-type
grounding connector
(not included)
Grounding lugs
(6-32, 1/8" diam.)
12 AWG copper wire
(not included)
3/4-inch
spacing
To properly ground the CPSMC0100-210 single-slot chassis:
1. Obtain one (1) grounding conductor (12 AWG copper wire gauge or
larger) with a two-hole, compression-type, grounding connector.
2. Attach the grounding conductor to the converter by placing the two-hole
connector onto the grounding lugs and fasten with the enclosed lock-
washers / lug-nuts at the proper torque (per the manufacturer’s
specification).
grounding lugs
3. Attach the opposite end of the
grounding conductor to the
common bonding network
(CBN) for telecom, or to earth
ground (if required) for non-
grounding
connector
and wire
telecom installations.
earth ground
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
[email protected] -- Click the “Transition Now” link for a live Web chat.
5
4
CPSMC0100-210
Troubleshooting
Contact Us
Technical Support
1.
Is the slide-in-module media converter properly installed into the single-
slot chassis?
Technical support is available 24 hours a day.
United States:
International:
1-800-260-1312
00-1-952-941-7600
NO
•
Ensure the slide-in-module media converter is firmly seated inside
the single-slot chassis. See page 2 for installation instructions.
Proceed to step 2.
Transition Now
•
YES
•
Chat live via the Web with Transition Networks Technical Support.
Proceed to step 2.
Web-Based Seminars
Transition Networks provides seminars via live web-based training.
2.
Is the Power LED on the slide-in-module media converter illuminated?
NO
•
•
•
Is the power adapter the proper type of voltage and cycle frequency
for the AC outlet? (See “Power Supply” on page 5.)
Is the power adapter properly installed in the single-slot chassis and
in the grounded AC outlet?
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
E-Mail
Ask a question anytime by sending an e-mail to our technical support staff.
Address
YES
•
Transition Networks
10900 Red Circle Drive,
Minnetonka, MN 55343, U.S.A.
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
telephone:
toll free:
fax:
952-941-7600
800-526-9267
952-941-2322
Declaration of Conformity
Name of Mfg:
Transition Networks
10900 Red Circle Drive, Minnetonka MN 55343 U.S.A.
Model:
Part Number:
Regulation:
CPSMC0100-210 Series Single-Slot PointSystem Chassis
CPSMC0100-210
EMC Directive 89/336/EEC
Purpose: To declare that the CPSMC0100-210 to which this declaration refers is in
conformity with the following standards:
EN 55022:1994+A1:1995+A2:1998 Class A&B; EN 55024:1998+A1:2002; FCC Part 15
Subpart B; 21CFR subpart J; EN 61000-3-2:2001; Telcordia GR-1089-CORE sect. 3.2.2
I, the undersigned, hereby declare that the equipment specified above conforms to
the above Directive(s) and Standard(s).
June, 2008
Stephen Anderson, Vice-President of Engineering
Date
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
[email protected] -- Click the “Transition Now” link for a live Web chat.
7
6
Compliance Information
CISPR/EN55022 Class A & B + EN55024
CE Mark
FCC Regulations
This equipment has been tested and found to comply with the limits for a Class A & B digital
device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference. In which case, the user will be required to correct the
interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A & B limits for radio noise for digital appa-
ratus set out on the radio interference regulations of the Canadian Department of
Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites
applicables aux appareils numériques de la Class A & B prescrites dans le Règlement sur le
brouillage radioélectrique édicté par le ministère des Communications du Canada.
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in
damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-
Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der
Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über
Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer
Konformität.
In accordance with European Union Directive 2002/96/EC of the European
Parliament and of the Council of 27 January 2003, Transition Networks will
accept post usage returns of this product for proper disposal. The contact
information for this activity can be found in the 'Contact Us' portion of this
document.
Trademark Notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright Restrictions
© 2004 Transition Networks.
All rights reserved. No part of this work may be reproduced or used in any form or by any
means – graphic, electronic or mechanical – without written permission from Transition
Networks.
Printed in the U.S.A.
33305.C
|