UH-042XR
Operating
Guide
CONTENTS
Introduction
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Technical Support & Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Included in your UH-042XR Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Getting Started
Battery Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Low Battery Alert. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Belt Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Operation
Power on/off. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Volume. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Selecting a Channel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
To Transmit and Receive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
To Operate in Duplex Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Scanning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Open Scan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Group Scan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Priority Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Programming Scan Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Continuous Tone Coded Squelch System (CTCSS) . . . . . . . . . . . . . . . . . . 11
Built-in Voice Activated Circuit (VOX) . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Drop-Out Delay. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Power Save . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Busy Channel Lock-out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Sending Call Tones. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Backlight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Keypad Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Battery Level Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Charging Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
UHF Channels and Frequencies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
CTCSS Codes and Frequencies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Controls & Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
INTRODUCTION
The UH-042XR is a portable two-way UHF-CB radio. It is compact, rugged and
fits easily in your hand. This hand held UHF radio will give you consistent,
outstanding performance in virtually all conditions and situations. To ensure that
you get the most from the UH-042XR’s features, please read this operating guide
carefully before using the unit.
FEATURES
➤ 40 Channels
➤ 500mW Output Power
➤ Up to 3 km range*
➤ LCD Display
➤ Group Scan
➤ Open Scan
➤ Duplex Capability
➤ 38 Built-in Continuous Tone Coded Squelch System (CTCSS)
➤ Monitor
➤ Busy Channel Lock-out
➤ LCD Back Light (Auto On for 5 Sec)
➤ Built-in Voice Activated Function (VOX)
➤ Auto Power Save
➤ Battery Level Indicator
➤ Built in Keypad Lock
➤ 2 Different Ring Tones
➤ Auto Squelch Control
* Range varies depending on the environment. 3km range is noted in a flat open
environment.
1
TECHNICAL SUPPORT AND SERVICE
Should you find it desirable or necessary to service your UH-042XR, we suggest
you contact the Uniden dealer where you purchased your radio. Your dealer will
be able to assist you with the complete service information.
If you require service that is within the terms of your warranty, you should present
a copy of your receipt to your dealer to authenticate your claim.
If you find it inconvenient to obtain service assistance from a dealer, please pack
your radio in suitable packaging that will provide adequate protection to your
radio. Enclose a note describing the problem, a copy of your receipt, and send it
prepaid to:
AUSTRALIA:
NEW ZEALAND:
Uniden Australia Pty Ltd
Customer Service Division
345 Princes Highway
Rockdale NSW 2216
Uniden New Zealand Ltd
Customer Service Division
150 Harris Road
East Tamaki, Auckland
Ph.
Fax.
(02) 9599-3355
(02) 9599-3278
Ph.
Fax.
(9) 273 8383
(9) 274 4253
Toll Free 1300 366 895
Toll Free 0800 4 UNIDEN
4 864336
Caution: Changes or modifications to this product not expressly approved by
Uniden; or operation of this product in any way other than as detailed by this
Operating Guide, can void your warranty and authority to operate this product.
2
INCLUDED IN YOUR UH-042XR PACKAGE
UH-042XR
Wrist Strap
Belt Clip
Operating Guide
Product Registration Card
and other printed materials
Note: If any of these items are missing from the box, contact your Uniden Dealer.
3
GETTING STARTED
BATTERY INSTALLATION
Your UH042XR radio uses 3 AA ALKALINE batteries for power.
Please refer to page 18 should you wish to use rechargeable batteries.
To install the batteries:
Do not mix old and new batteries to avoid damage to the unit.
1. Make sure your radio is off.
2. Release the battery cover clip, then
remove the battery cover.
3. Insert 3 AA ALKALINE batteries
according to the polarity symbols
inside the battery compartment.
Tab holes
4. Align the battery cover tabs with the
UH042XR tab holes then replace
the cover.
Note: Batteries are not supplied
4
LOW BATTERY ALERT
The LCD on your radio shows a battery
meter in the lower right corner.
icon indicates a fully powered
unit. As the batteries lose power,
will flash.
When the batteries in the unit are low,
the unit will go into a Battery Low/Sleep Mode. The Scan Mode, Transmit,
Transmit Call Tone Mode are disabled. Replace the batteries immediately to
continue using the radio.
BELT CLIP
As you will usually use your radio when you are
out and about, the unit comes equipped with a
belt clip to securely fasten the unit to your belt,
pocket or purse.
To remove the belt clip, turn the screw
counterclockwise.
To attach the belt clip:
1. Insert the belt clip screw into the slot on
the belt clip.
2. Align the screw with the hole on the back
of the radio and turn it clockwise, using a
Phillips screwdriver to secure the belt
clip. Do not over-tighten.
WRIST STRAP
1. Insert the short end of the strap through
the belt clip hole.
2. Slip the long end through the loop to
enclose the clip in the strap and pull tightly.
5
OPERATION
➤ When you press any key (except PTT), a short tone sounds.
➤ See the Controls and Indicators page at the back of this operating guide for
button and key operations.
POWER ON/OFF
To turn the unit ON, rotate the [ON/OFF VOL]
clockwise until a “click” is heard. A channel number
and battery level should appear on the display.
To turn the unit OFF, rotate the [ON/OFF VOL]
knob counter-clockwise until a “click” is heard.
The display will disappear.
VOLUME
1. Press the [MON] button to hear
background noise. The “BUSY” icon
appear on the display.
will
2. Turn the [ON/OFF VOL] control clockwise to
increase the volume, counterclockwise to
decrease the volume.
6
SELECTING A CHANNEL
Press [➤] or [➤] to select the desired channel.
Note: If you press and hold the [➤] or [➤],
scan
vox
dup
channel numbers will scroll rapidly.
mem
bcl
os/gs
ctcss
TO TRANSMIT AND RECEIVE
The UH-042XR uses the 40 UHF-CB Channels. For your reference a list of the
available channels and corresponding frequencies is printed at the end of this
manual.
1. The maximum RF transmit power of UH-042XR is 500 mWatts.
2. Before you transmit, listen for
activity on the selected channel.
3. When the channel is clear, press and
PTT
Switch
hold the [PTT] to transmit.
appears on the LCD.
scan
dup
vox
mem
Hold the radio with microphone approximately two inches in front of your mouth
with the antenna at approximately 45˚ angle away from your head. Speak in a clear,
normal conversational voice.
4. When you have finished speaking, release the [PTT] and listen for a response.
TX icon then disappears from the LCD.
The display shows
when a
transmission is being received by
your radio.
7
TO OPERATE IN DUPLEX MODE
vox
Eg. CH01 is being used in your area for repeater
purpose.
dup
mem
bcl
os/gs
ctcss
Press [DUP] momentarily. The DUP icon appears.
Press [DUP] again to deactivate the duplex operation.
UH-042XR will return to simplex operation.
DUP icon disappears.
SCANNING
The UH-042XR has two types of scanning; Open Scanning (OS) and Group Scanning
(GS), giving you flexibility and allowing you to use the radio more effectively.
Scanning allows you to search for active channels programmed in the OS or GS
memory.
To initiate scanning,
1. Assuming the unit is on CH01 when switched on.
2. Press [SCAN] and scanning starts.
Scan icon flashes during scanning.
scan
dup
vox
mem
os/gs
bcl
ctcss
1. Open Scan (OS) Mode
(the absence of GS icon indicates that the unit is on OS mode)
Allows continuous scanning of channels stored in the Open Scan (OS) memory.
If an active channel is found, scanning will stop on that channel.
Note: The factory has preprogrammed all the 40 UHF channels into the Open Scan
channel memory. However, you can change or customise the channels by
following the steps on programming Scan Channels on pages 10.
8
Example: CH40 becomes active
If the received signal ceases, the unit will wait for at
least 3 seconds for the signal to return, otherwise
scanning resumes.
To skip the active channel, press [MEM] momentarily. Scanning resumes.
To deactivate SCAN, press the [SCAN] or [PTT].
Note:
1. If SCAN is deactivated while in an active channel, the UH-042XR will stay on that
active channel. If no other channels are active, the UH-042XR will reinstate the
starting channel.
2. Pressing [OS/GS] will switch to Group Scanning.
2. Group Scan (GS) Mode
To use GS Mode Scanning, press the [OS/GS]
key. GS icon appears on the display.
scan
dup
vox
mem
os/gs
bcl
ctcss
1. When [SCAN] is pressed
during Group Scan Mode, SCAN icon will
flash and Group Scan Scanning begins.
2. To deactivate GS scan, press [SCAN] or [PTT].
Note:
1. If SCAN is deactivated while it is tuned to an
active channel, the UH-042XR will stay on that
active channel. If none of the channels are
active, the UH-042XR will reinstate the Priority
channel.
2. If GS Scanning is initiated when there are no channels programmed in GS
memory, an error tone will be heard and scanning will not start.
3. Pressing [OS/GS] will switch to Open Scanning.
9
PRIORITY CHANNEL
The Priority Channel feature allows user to monitor one of 40 channels in the
UH-042XR, monitoring it every 1.5secs during Group Scanning.
Choosing a Priority Channel
The starting channel, when Group Scanning is initiated, is always the Priority
Channel. To change the priority channel setting while scanning, (eg. PRI Channel
is CH17 (476.825 MHz))
a. press [➤], to select a higher channel
(scanning pauses)
or
b. press [➤], to select a lower channel
Programming Scan Channels
1. Select which Scanning Mode you wish
to use on the channel
scan
dup
OS or GS Mode
vox
mem
os/gs
Note: OS is indicated by the absence of the GS icon
bcl
ctcss
2. Select the channel you want to store by
pressing [➤] or [➤]
3. Pressing [MEM] momentarily to store.
MEM icon appears and beep sounds are
heard.
scan
dup
mem
bcl
4. To remove the channel from Memory, press
[MEM] momentarily. MEM icon disappears and
beep sounds are heard.
os/
ctcss
10
CONTINUOUS TONE CODED SQUELCH SYSTEM (CTCSS)
CTCSS is a feature that allows a group to talk to each other without hearing other
users on the same channel.
NOTE : Uniden discourages the use of CTCSS feature until the Australian
Communications Authority (ACA) grants the use of CTCSS on CB frequencies.
Programming CTCSS Code
1. Select a desired channel to be used with CTCSS.
2. Press and hold [CTCSS] for 1.5 secs. CTCSS code
indicator blinks.
3. Press [➤] or [➤] to select the desired CTCSS code.
4. Press [CTCSS] to save the selected code.
CTCSS icon stops blinking.
scan
dup
NOTE: There are 38 available CTCSS tone per
vox
mem
os/gs
channel. Channel 5 and 11 should not be
programmed CTCSS. These channels shall be
bcl
ctcss
used for emergency purposes only and must
be ‘OPEN’ at all times.
11
CTCSS Scan Operation
1. Press [SCAN] to start scanning (GS or OS) mode.
2. During scanning if a signal is sensed on a CTCSS CH, the
UH-042XR stops for about 400msecs (decode time) to decode the CTCSS
code. If there is no code or the receive code does not match the one
programmed on the unit, the unit resumes scanning.
On the example below only radio 1 and 9 can communicate or hear each other
because they are using the same or common CTCSS code.
CH1
Code 1
CODE 1
CH1
Code 1
CH1
Code 7
CH1
No CTCSS Code
12
BUILT-IN VOICE ACTIVATED CIRCUIT (VOX)
VOX feature enables user to transmit automatically by speaking on the
microphone of the VOX headset (not supplied) without pressing the PTT switch.
NOTE: VOX feature will not work without the Headset Microphone.
Built in [PTT] of UH-042XR is temporarily disabled, however accidental
pressing of [PTT] will cause the unit to transmit briefly.
To activate VOX
1. Turn the UH-042XR OFF.
2. Press and hold [VOX] while turning the radio ON. “VOX” appears on the
bottom left of the display.
3. To set sensitivity. Press and hold[VOX],
scan
dup
vox
“VOX” icon starts blinking.
mem
os/gs
bcl
ctcss
4. Press either [➤] or [➤] within 10 secs. to
select the desired VOX level number
(9 with the lowest sensitivity to 1 with the highest sensitivity).
5. Press [VOX] to save the selected level. “VOX”
icon stops blinking.
6. Install VOX Headset (not supplied) to
UH-042XR
Installing VOX Headset
1. Remove SPEAKER MIC COVER.
2. Attach VOX headset mic by pushing jack down
Cover
through to the speaker mic port of UH-042XR
until it sits firmly on the radio.
Headset
Mic
13
To De-activate VOX
1. Turn OFF UH-042XR.
2. Remove VOX Headset from UH-042XR.
3. Press and hold [VOX] while turning the radio ON.
“VOX” icon disappears.
4. UH-042XR returns to PTT operation.
Note: Turning ON the radio without removing the VOX headset will cause the unit
to transmit continuously.
DROP-OUT DELAY
While scanning, the UH-042XR stops at a busy channel and receives a
transmission. When the received signal is over, the unit will wait for 3 seconds for
the return of the signal, otherwise, the radio resumes scanning.
POWER SAVE
Battery Save feature extends the battery life by switching the receiver circuit
power ON and OFF. This feature automatically activates during stand by mode
(RX mode without signal). It turns OFF automatically when a signal is present,
and activates again after channel inactivity.
14
BUSY CHANNEL LOCK-OUT(BCL)
This feature prevents accidental transmission on a busy channel.
This is recommended on channels where CTCSS is being used. If the channel is
“active” and the signal is coming from a non or different CTCSS code user the
BCL feature will prevent you from transmitting.
To activate BCL
Press and hold [BCL] for 1.5 secs until “BCL”
scan
appears on display.
dup
mem
os/
To De-activate BCL
bcl
ctcss
Press and hold [BCL] for 1.5 secs. until “BCL”
disappears from the display.
SENDING CALL TONES
The UH-042XR is equipped with two types of tones
that user can use to alert other users or identify yourself prior to transmission.
You can also apply the signal at the end of the transmission.
To use the Call Tones,
Press [➤] (for call tone A) or [➤] (for call
PTT
tone B) while pressing the [PTT] switch. Call tone
Switch
will be transmitted for 3 seconds. (You will also
scan
dup
hear this tone from your radio as well).
vox
mem
os/gs
15
BACK LIGHT
The Liquid Crystal Display (LCD) is backlit for easy viewing at night or in low
light situations. The back lighting automatically switches ON every time a key
(except PTT) is pressed. It turns OFF 5secs after the last key is pressed.
KEYPAD LOCK
To prevent accidental entries, you can
lock the keypad.
Press and hold the [LOCK] button for
1.5 secs. until it beeps to activate Key Lock.
icon appears.
To unlock the keypad, press and hold the [LOCK]
button again for 1.5 secs.
icon disappears.
Note: When the Key Lock is active, a warning beep will be heard if you attempt to
press the keys.
MONITOR
This feature enables users to listen in for
weak signals on the current channel at the press of
a button.
To use monitor,
•
•
For brief listening, press [MON]
For continuous listening. Press and hold [MON]
for 2 secs. A two tone beep will be heard and
the receiver circuit will stay open, letting in
both the noise & weak signals.
•
•
Display shows
icons.
To return to normal receive mode press [MON],
[SCAN], [PTT] [➤] or [➤].
16
BATTERY LEVEL DISPLAY
The
icon in the bottom right hand corner of the screen indicates the UH-
042XR current battery voltage level at all times. The battery level is displayed in
3 levels:
LEVEL 3
Battery 100% full
LEVEL 2
Battery approx
70% capacity
LEVEL 1
Battery approx
30% capacity
Almost Empty
Note:
When [PTT] SW is pressed at
Level Empty, battery icon and
channel number will flash
17
CHARGING BATTERIES
Warning Notice! Use only the AAD042S
optional power adaptor if rechargeable
batteries will be used in the UH042XR.
•
Turn the UH042XR [ON/OFF VOL] knob
off and connect the AC adaptor plug to the
mic jack.
•
Battery charging times vary. A longer time is
required to charge higher capacity batteries.
Rechargeable Batteries Charging Time
600mAH Ni-Cad
1000mAH Ni-Cad
1300mAH Ni-MH
14-16 hrs
24-27 hrs
31-35 hrs
•
Disconnect the AC adaptor from the unit when charging is completed.
18
UHF CHANNELS & FREQUENCIES
Ch.
01
02
03
04
05
06
07
08
09
10
11
Freq.
Usage
Ch.
21
22
23
24
25
26
27
28
29
30
Freq.
Usage
476.425
476.450
476.475
476.500
Simplex/Duplex
Simplex/Duplex
Simplex/Duplex
Simplex/Duplex
476.925
476.950
476.975
477.000
477.025
477.050
477.075
477.100
477.125
477.150
Simplex
Simplex
Simplex
Simplex
Simplex
Simplex
Simplex
Simplex
Simplex
Simplex
*476. 525 Simplex/Duplex
476.550
476.575
476.600
476.625
476.650
#476.675
Simplex/Duplex
Simplex/Duplex
Simplex/Duplex
Repeater
Repeater
Back-up
Emergency Channel
31
32
33
34
35
36
37
38
39
40
477.175
477.200
477.225
477.250
477.275
477.300
477.325
477.350
477.375
477.400
Simplex
Simplex
Simplex
Simplex
Simplex
Simplex
Simplex
Simplex
Simplex
Simplex
12
13
14
15
16
17
18
19
20
476.700
476.725
476.750
476.775
476.800
476.825
476.850
476.875
476.900
Repeater
Repeater
Repeater
Repeater
Repeater
Repeater
Repeater
Repeater
Repeater
* Emergency calling for both simplex and duplex operation
Please do not use this channel in non-emergency cases.
# Back-up Emergency Channel
19
CTCSS CODES & FREQUENCIES
Code No. Freq. (Hz)
Code No. Freq. (Hz) Code No.
Freq. (Hz)
162.2
167.9
173.8
179.9
186.2
192.8
203.5
210.7
218.1
225.7
233.6
241.8
250.3
00(‘oF’)
01
OFF
67.0
71.9
74.4
77.0
79.7
82.5
85.4
88.5
91.5
94.8
97.4
100.0
13
14
15
16
17
18
19
20
21
22
23
24
25
103.5
107.2
110.9
114.8
118.8
123.0
127.3
131.8
136.5
141.3
146.2
151.4
156.7
26
27
28
29
30
31
32
33
34
35
36
37
38
02
03
04
05
06
07
08
09
10
11
12
OPTIONAL ACCESSORIES
•
•
•
•
Speaker Microphone (SM-050)
AC Adaptor (AAD-042S)
VOX Headset (VM-052)
Standard Headset (HM-050)
TECHNICAL SPECIFICATIONS
General
Channels
Transmit 40 (with Duplex Channel Support)
Receive 40
Oper. Temp.
Antenna
0˚C - +55˚C
Fixed
Microphone
Built-in Electret type
20
Display
Liquid Crystal Display
Speaker
Power Source
Size
Weight
Operating Time at
Duty Cycle
36mm Round, 8Ω
AA Size Battery x 3pcs
(with antenna) 180(H) x 62(W) x 32(D)mm
150g (with Antenna & without Battery)
17 hrs (1.2V, 600mAH Ni-Cd Batteries)
25 hrs (1.2V, 1000mAH Ni-Cd Batteries)
32 hrs (1.25V, 1300mAH Ni-MH Batteries)
38 hrs (1.5V, 1500mAH Alkaline Batteries)
5 Secs. Tx, 5 Secs. Rx,
90 Secs. Standby
Transmitter
Frequency Control
Frequency Range
Frequency Stability
Power Output
Phase Locked Loop
476.425 to 477.4 MHz
3 ppm
0.5W
Spurious Emissions
Current Drain
-40 dBm
320mA
Receiver
Receiver Type
Dual Conversion
Super Heterodyne
Phase Locked Loop
System for Local Oscillator
476.425 to 477.4 MHz
0.22 µV
Frequency Range
Sensitivity @
12 dB SINAD
Squelch Sensitivity
Audio Frequency
Response
0.19 µV (Threshold)
500Hz, 5dB
(ref: 1KHz, 3KHz Dev.) 2000Hz, -6dB
Selectivity
50dB
Hum & Noise Ratio
Audio Output Drain
Current Drain
37dB
0.15W (10% THD)
150 mA
50mW output
Specifications shown are typical and subject to change without notice.
21
WARRANTY
UNIDEN UH-042XR UHF CB RADIO
Limited One Year Warranty
Note: Please keep your sales docket as it provides evidence of warranty.
Warrantor:
Uniden Australia Pty Limited ACN 001 865 498
Uniden New Zealand Limited
Elements of Warranty: Uniden warrants to the original retail owner for the duration of this warranty, its
UH-042XR UHF CB Transceiver Radio (hereinafter referred to as the Product) to be free from defects in
materials and craftsmanship with only the limitations or exclusions set out below.
Warranty Duration: This warranty to the original retail owner only, shall terminate and be of no
further effect ONE (1) Year after the date of original retail sale. This warranty will be deemed invalid
if the product is; (A) Damaged or not maintained as reasonable and necessary, (B) Modified, altered
or used as part of any conversion kits, subassemblies, or any configurations not sold by Uniden, (C)
Improperly installed, (D) Repaired by someone other than an authorised Uniden Repair Agent for a
defect or malfunction covered by this warranty, (E) Used in conjunction with any equipment or parts
or as part of a system not manufactured by Uniden, (F) Installed, programmed or serviced by anyone
other than an authorised Uniden Repair Agent, or (G) Where the Serial Number label of the product
has been removed or damaged beyond recognition.
Parts Covered: This warranty covers for 1 year, the UHF CB Transceiver Unit only. Accessories: Belt
CLip and Wrist Strap are covered for 90 days.
Statement of Remedy: In the event that the product does not conform to this warranty at any time
while this warranty is in effect, the warrantor at its discretion, will repair the defect or replace the
product and return it to you without charge for parts and service. This warranty does not cover
provide for the reimbursement or payment of incidental or consequential damages.
Warranty card: If a warranty card has been included with this product, please fill it in and return it
to us within 14 days of purchase. Your name and serial number of the product will then be registered
in our database and this will help us process your claim with greater speed and efficiency should you
require warranty service.
Procedure for obtaining performance or warranty: In the event that the Product does not
conform to this warranty, the Product should be shipped or delivered, freight prepaid, with evidence
of original purchase, (eg. a copy of the sales docket), to the warrantor at:
UNIDEN AUSTRALIA PTY LIMITED
Service Division
345 Princes Highway, Rockdale, NSW 2216
Ph (02) 9599 3577 Fax (02) 9599 3278 Toll Free 1300 366 895
UNIDEN NEW ZEALAND LTD
Service Division
150 Harris Road, East Tamaki, Auckland
Ph (9) 273 8383 Fax (9) 274 4253 Toll Free 0800 4UNIDEN
4864336
Customers in other states should ship or deliver the Product freight pre-paid to the nearest Uniden
Authorised Repair Centre. (Contact Uniden for the Warranty Agent nearest you.)
22
CONTROLS & INDICATORS
1
2
3
13
14
4
5
6
7
15
scan
vox
9
dup
mem
bcl
os/gs
ctcss
10
11
12
8
23
A
B
J
I
H
F
G
K
L
C
D
E
A. Transmit
G. Scanning
B. Channel Numbers
C. Key Lock
H. Group Scanning
I. Receiving
D. Memory
J. CTCSS Tone and VOX Levels
K. Busy Channel Lock
L. VOX
E. Battery Level Indicator
F. Duplex Transmit
1. Speaker Jack
2. Microphone Jack
3. On/Off Volume
4. LCD Display
5. Up Button
10. Open/Group Scan and
CTCSS Button
11. Memory/BCL Button
12. Duplex and Key Lock
On/Off Button
13. PTT (Push-to-talk) Button
14. Monitor Switch
15. Belt Clip
6. Down Button
7. Microphone
8. Speaker
9. Scan and VOX Button
24
© 2000 Uniden Australia Pty Limited/Uniden New Zealand Limited
UTZZ01877ZZ
|