Unified Brands Ventilation Hood 4000 Series User Manual

The Avtec EcoArch 4000 Series  
Model Number1  
Hood Section Dimensions2  
Application  
CFM/Ft3  
Available length of 48”to 192”  
x 30”high  
EA4-DDLLL-30  
600˚F  
150  
Available length of 48”to 192”  
x 30”high  
EA4-DDLLL-30  
400˚F  
130  
1 DD = Depth in inches, LLL=Length in inches, 30=Height in inches.  
Example: EA4-54120-30 stands for a 54deep x 120long x 30high unit.  
2 For hood lengths longer than 192, multiple sections can be grouped together.  
3 Minimum CFM may vary based on cooking equipment application.  
The Most Energy Efficient  
Ventilation System.  
Up to 40% Annual Energy Savings  
Using Exclusive Design Features  
The Avtec EcoArch combines  
both an economical and  
environmentally safe solution for  
the need for high-quality, cost-  
effective ventilation performance  
in today’s foodservice kitchens.  
Exclusive Aerodynamic Arch – Dramatically reduces the amount of turbulence  
within the canopy reservoir. About 70% of the contaminated air is exhausted  
immediately out of the reservoir.  
High Velocity Exhaust Slot – The higher rate of speed at the slot in addition to its  
location at the top of the canopy effectively removes the contaminated air working  
in conjunction with the arch top.  
The EcoArch ventilation system  
addresses the growing need  
to reduce the amount of  
Easier and Safer Removal of Filter Medium  
Unlike tradition rear filter locations, EcoArch exhaust plenum and filters are located  
in the front of the hood eliminating the need to climb on top of cooking equipment  
for daily removal and cleaning.  
conditioned air from a kitchen  
space. The combination of the  
patent pending arch top and  
the front mounted high velocity  
exhaust slot reduces the amount  
of exhausted CFM by 45%  
compared to traditional CFM rates.  
This translates into an annual  
electric and gas savings  
Sample Energy Savings  
150 cfm/ft (EcoArch) vs. 250 cfm/ft (traditional unit)  
12’Hood, 400°F, Gas & Electric, Based on 2006 Utility Rates  
Location  
cfm/ft Annual Gas Annual Electric Total Energy Annually Savings %  
New York, NY  
New York, NY  
Total Savings  
Atlanta, GA  
250  
150  
$5425  
$3255  
$2170  
$3728  
$2237  
$1491  
$1364  
$828  
$536  
$943  
$571  
$371  
$6789  
$4083  
$2706  
$4671  
$2808  
$1863  
of up to 40%.  
40%  
40%  
Now that’s maximizing your  
energy and cost savings!  
250  
150  
Atlanta, GA  
Total Savings  
 
EAVS-4000S-0907  

Taylor Blender C302 User Manual
Top Innovations Iron SF 475 User Manual
Toshiba CRT Television 27A35C User Manual
Toshiba Digital Camera PDR M11 User Manual
Toshiba Security Camera IK 64WDA User Manual
TRENDnet Network Hardware TEW 638APB User Manual
Tripp Lite TV Cables EZB DVIM 2 User Manual
Vector Work Light 90510392 User Manual
Vicks Thermometer V934 User Manual
Weed Eater Lawn Mower 191064 User Manual